Developments in optics and performance at BL13-XALOC, the macromolecular crystallography beamline at the Alba Synchrotron
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
BL13-XALOC is currently the only macromolecular crystallography beamline at the 3 GeV ALBA synchrotron near Barcelona, Spain. The optics design is based on an in-vacuum undulator, a Si(111) channel-cut crystal monochromator and a pair of KB mirrors. It allows three main operation modes: a focused configuration, where both mirrors can focus the beam at the sample position to 52 µm × 5.5 µm FWHM (H × V); a defocused configuration that can match the size of the beam to the dimensions of the crystals or to focus the beam at the detector; and an unfocused configuration, where one or both mirrors are removed from the photon beam path. To achieve a uniform defocused beam, the slope errors of the mirrors were reduced down to 55 nrad RMS by employing a novel method that has been developed at the ALBA high-accuracy metrology laboratory. Thorough commissioning with X-ray beam and user operation has demonstrated an excellent energy and spatial stability of the beamline. The end-station includes a high-accuracy single-axis diffractometer, a removable mini-kappa stage, an automated sample-mounting robot and a photon-counting detector that allows shutterless operation. The positioning tables of the diffractometer and the detector are based on a novel and highly stable design. This equipment, together with the operation flexibility of the beamline, allows a large variety of types of crystals to be tackled, from medium-sized crystals with large unit-cell parameters to microcrystals. Several examples of data collections measured during beamline commissioning are described. The beamline started user operation on 18 July 2012.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Formation of Optical Images by X-Rays
Kirkpatrick, P. H., & Baez, A. V. (1948) · Journal of the Optical Society of America · doi:10.1364/josa.38.000766 · Cited by 1,396 · cited 1×
“The focusing system consists of a vertical focusing mirror (VFM) and a horizontal focusing mirror (HFM) that are placed orthogonally in a Kirkpatrick–Baez (KB) configuration (Kirkpatrick & Baez, 1948) in two independent positioning supports manufactured by IRELEC (Saint-Martin-d’Hères, France).”
MethodRadiation damage in macromolecular crystallography: what is it and why should we care?
Garman, E. F. (2010) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444910008656 · Cited by 366 · cited 1×
“…of the beam to the size of the crystal improves the ratio between the diffracted intensities and the background scattering, which allows us to better estimate the radiation damage, provided that the beam illuminates uniformly the crystal (Bourenkov & Popov, 2006; Holton, 2009; Garman, 2010).”
BackgroundA beginner's guide to radiation damage
Holton, J. M. (2009) · Journal of Synchrotron Radiation · doi:10.1107/s0909049509004361 · Cited by 260 · cited 1×
“…of the beam to the size of the crystal improves the ratio between the diffracted intensities and the background scattering, which allows us to better estimate the radiation damage, provided that the beam illuminates uniformly the crystal (Bourenkov & Popov, 2006; Holton, 2009; Garman, 2010).”
BackgroundCHOOCH: a program for deriving anomalous-scattering factors from X-ray fluorescence spectra
Evans, G., & Pettifer, R. F. (2001) · Journal of Applied Crystallography · doi:10.1107/s0021889800014655 · Cited by 253 · cited 1×
“Typically a fluorescence scan takes 100 s and the fluorescence data are processed automatically after the scan with CHOOCH (Evans & Pettifer, 2001).”
MethodEDNA: a framework for plugin-based applications applied to X-ray experiment online data analysis
Incardona, M.-F., Bourenkov, G. P., Levik, K., Pieritz, R. A., Popov, A. N., & Svensson, O. (2009) · Journal of Synchrotron Radiation · doi:10.1107/s0909049509036681 · Cited by 228 · cited 1×
“The diffraction strategy is calculated by EDNA (Incardona et al., 2009) and all the common processing software packages in MX are available to the users.”
MethodWill reduced radiation damage occur with very small crystals?
Nave, C., & Hill, M. A. (2005) · Journal of Synchrotron Radiation · doi:10.1107/s0909049505003274 · Cited by 164 · cited 1×
“Although microbeams of <10 mm diminish the radiation damage per absorbed dose (Nave & Hill, 2005; Cowan & Nave, 2008; Sanishvili et al., 2010), at the same time it has been shown that matching the dimensions of the beam to the size of the crystal improves the ratio between the diffracted…”
BackgroundA quantitative approach to data-collection strategies
Bourenkov, G. P., & Popov, A. N. (2005) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444905033998 · Cited by 109 · cited 1×
“…of the beam to the size of the crystal improves the ratio between the diffracted intensities and the background scattering, which allows us to better estimate the radiation damage, provided that the beam illuminates uniformly the crystal (Bourenkov & Popov, 2006; Holton, 2009; Garman, 2010).”
BackgroundQuantifying instrument errors in macromolecular X-ray data sets
Diederichs, K. (2010) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444910014836 · Cited by 82
Structural Basis of Rap Phosphatase Inhibition by Phr Peptides
del Sol, F. G., & Marina, A. (2013) · PLoS Biology · doi:10.1371/journal.pbio.1001511 · Cited by 79 · cited 1×
“As a result, the scientific production has started in earnest with the first structures being deposited in the Protein Data Bank and the first papers being published in peer-reviewed journals (Bacarizo & CamaraArtigas, 2013; Gallego et al., 2013; Gallego del Sol & Marina, 2013; Otero et al., 2013).”
BackgroundThe optimum conditions to collect X-ray data from very small samples
Cowan, J. A., & Nave, C. (2008) · Journal of Synchrotron Radiation · doi:10.1107/s0909049508014623 · Cited by 52 · cited 1×
“Although microbeams of <10 mm diminish the radiation damage per absorbed dose (Nave & Hill, 2005; Cowan & Nave, 2008; Sanishvili et al., 2010), at the same time it has been shown that matching the dimensions of the beam to the size of the crystal improves the ratio between the diffracted…”
Background
Cited by
Varejão, N., De-Andrade, R. A., Almeida, R. V., Anobom, C. D., Foguel, D., & Reverter, D. (2018) · Structure · doi:10.1016/j.str.2017.12.004 · Cited by 14
Metadata
- Authors
- Juanhuix, J., Gil-Ortiz, F., Cuní, G., Colldelram, C., Nicolás, J., Lidón, J., Boter, E., Ruget, C., Ferrer, S., & Benach, J.
- Venue
- Journal of Synchrotron Radiation
- Published
- 2014-05-20
- Volume
- 21
- Issue
- 4
- Pages
- 679-689
- ISSN
- 0909-0495 (ISSN-L)
- 1600-5775
- OpenAlex
- W2158860343
- Cited by
- 203
- References
- 13
- FWCI
- 7.59
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.