CoChat

GigaFRoST: the gigabit fast readout system for tomography

Open access
Mokso, Rajmund, Schlepütz, Christian M., Theidel, Gerd, Billich, Heiner, Schmid, Elmar, Celcer, Tine, Mikuljan, Gordan, Sala, Leonardo, Marone, Federica, Schlumpf, Nick, Stampanoni, Marco · 2017 · Journal of Synchrotron Radiation
Cited by 188

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Owing to recent developments in CMOS technology, it is now possible to exploit tomographic microscopy at third-generation synchrotron facilities with unprecedented speeds. Despite this rapid technical progress, one crucial limitation for the investigation of realistic dynamic systems has remained: a generally short total acquisition time at high frame rates due to the limited internal memory of available detectors. To address and solve this shortcoming, a new detection and readout system, coined GigaFRoST, has been developed based on a commercial CMOS sensor, acquiring and streaming data continuously at 7.7 GB s−1 directly to a dedicated backend server. This architecture allows for dynamic data pre-processing as well as data reduction, an increasingly indispensable step considering the vast amounts of data acquired in typical fast tomographic experiments at synchrotron beamlines (up to several tens of TByte per day of raw data).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1107/s1600577517013522

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • In-operando high-speed tomography of lithium-ion batteries during thermal runaway

    Finegan, D. P., Scheel, M., Robinson, J. B., Tjaden, B., Hunt, I., Mason, T. J., Millichamp, J., Di Michiel, M., Offer, G. J., Hinds, G., et al. (2015) · Nature Communications · doi:10.1038/ncomms7924 · Cited by 844 · cited 1×

    “…https://www.pco.de) fast CMOS detector, which since its introduction in 2008 has enabled many of the spectacular achievements in fast synchrotron-based imaging (Baker et al., 2012; Rack et al., 2013; dos Santos Rolo et al., 2014; Mokso et al., 2015; Finegan et al., 2015; Maire et al., 2016).”
    Background
  • Regridding reconstruction algorithm for real-time tomographic imaging

    Marone, F., & Stampanoni, M. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512032864 · Cited by 441 · cited 1×

    “Both tomographic datasets were acquired under the same experimental conditions and reconstructed with the same Fourier implementation of the Radon transform (Marone & Stampanoni, 2012).”
    MethodSelf-citation
  • In Vivo Time-Resolved Microtomography Reveals the Mechanics of the Blowfly Flight Motor

    Walker, S. M., Schwyn, D. A., Mokso, R., Wicklein, M., Müller, T., Doube, M., Stampanoni, M., Krapp, H. G., & Taylor, G. K. (2014) · PLoS Biology · doi:10.1371/journal.pbio.1001823 · Cited by 182 · cited 1×

    “Functional anatomy and biomechanics (Walker et al., 2014) have replaced simple static anatomic studies.”
    BackgroundSelf-citation
  • Fast microtomography using high energy synchrotron radiation

    Di Michiel, M., Merino, J. M., Fernandez-Carreiras, D., Buslaps, T., Honkimäki, V., Falus, P., Martins, T., & Svensson, O. (2005) · Review of Scientific Instruments · doi:10.1063/1.1884194 · Cited by 169 · cited 1×

    “Already then, it was, however, demonstrated that it was possible to acquire a tomogram in less than a minute (Di Michiel et al., 2005; Lambert et al., 2010), and today 20 tomographic scans may be acquired within ISSN 1600-5775 1 second (Mokso et al., 2013; dos Santos Rolo et al., 2014; Maire et…”
    Background
  • Scientific data exchange: a schema for HDF5-based storage of raw and analyzed data

    Carlo, F. D., Gürsoy, D., Marone, F., Rivers, M. L., Parkinson, D. Y., Khan, F., Schwarz, N., Vine, D. J., Vogt, S., Gleber, S.-C., et al. (2014) · Journal of Synchrotron Radiation · doi:10.1107/s160057751401604x · Cited by 109 · cited 1×

    “For the GigaFRoST data, we use the Scientific Data Exchange format (De Carlo et al., 2014).”
    MethodSelf-citation
  • A four-dimensional X-ray tomographic microscopy study of bubble growth in basaltic foam

    Baker, D. R., Brun, F., O’Shaughnessy, C., Mancini, L., Fife, J. L., & Rivers, M. L. (2012) · Nature Communications · doi:10.1038/ncomms2134 · Cited by 106 · cited 2×

    “Similarly, in materials science, investigating the mechanical deformation of internal structures or looking into geophysical processes have attracted a lot of attention during recent years (Maire et al., 2016; Baker et al., 2012).”
    Background
  • In vivo X-ray cine-tomography for tracking morphological dynamics

    dos Santos Rolo, T., Ershov, A., van de Kamp, T., & Baumbach, T. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1308650111 · Cited by 104 · cited 4×

    “Dimax (PCO AG, Germany; https://www.pco.de) fast CMOS detector, which since its introduction in 2008 has enabled many of the spectacular achievements in fast synchrotron-based imaging (Baker et al., 2012; Rack et al., 2013; dos Santos Rolo et al., 2014; Mokso et al., 2015; Finegan et al., 2015; Maire et al., 2016).”
    BackgroundInfluential
  • Coarsening Foams Robustly Reach a Self-Similar Growth Regime

    Lambert, J., Mokso, R., Cantat, I., Cloetens, P., Glazier, J. A., Graner, F., & Delannay, R. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.248304 · Cited by 80 · cited 2×

    “Already then, it was, however, demonstrated that it was possible to acquire a tomogram in less than a minute (Di Michiel et al., 2005; Lambert et al., 2010), and today 20 tomographic scans may be acquired within ISSN 1600-5775 1 second (Mokso et al., 2013; dos Santos Rolo et al., 2014; Maire et…”
    BackgroundSelf-citation
  • Towards on-the-fly data post-processing for real-time tomographic imaging at TOMCAT

    Marone, F., Studer, A., Billich, H., Sala, L., & Stampanoni, M. (2017) · Advanced Structural and Chemical Imaging · doi:10.1186/s40679-016-0035-9 · Cited by 77 · cited 2×

    “Currently the preview is available for single radiographic projections, but the nearly real-time reconstruction of single tomographic slices is an ongoing development (Marone et al., 2017).”
    BackgroundSelf-citation
  • Four-dimensional in vivo X-ray microscopy with projection-guided gating

    Mokso, R., Schwyn, D. A., Walker, S. M., Doube, M., Wicklein, M., Müller, T., Stampanoni, M., Taylor, G. K., & Krapp, H. G. (2015) · Scientific Reports · doi:10.1038/srep08727 · Cited by 69 · cited 1×

    “…https://www.pco.de) fast CMOS detector, which since its introduction in 2008 has enabled many of the spectacular achievements in fast synchrotron-based imaging (Baker et al., 2012; Rack et al., 2013; dos Santos Rolo et al., 2014; Mokso et al., 2015; Finegan et al., 2015; Maire et al., 2016).”
    BackgroundSelf-citation

Show all 13 references

Cited by

Metadata

Authors
Mokso, R., Schlepütz, C. M., Theidel, G., Billich, H., Schmid, E., Celcer, T., Mikuljan, G., Sala, L., Marone, F., Schlumpf, N., & Stampanoni, M.
Venue
Journal of Synchrotron Radiation
Published
2017-10-17
Volume
24
Issue
6
Pages
1250-1259
ISSN
  • 0909-0495 (ISSN-L)
  • 1600-5775
OpenAlex
W2766746267
Cited by
188
References
13
FWCI
15.72
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.