CoChat

ID30B – a versatile beamline for macromolecular crystallography experiments at the ESRF

Open access
McCarthy, Andrew A., Barrett, Ray, Beteva, Antonia, Caserotto, Hugo, Dobias, Fabien, Felisaz, Franck, Giraud, Thierry, Guijarro, Matias, Janocha, Robert, Khadrouche, Akim, Lentini, Mario, Leonard, Gordon A., Lopez Marrero, Marcos, Malbet-Monaco, Stephanie, McSweeney, Sean, Nurizzo, Didier, Papp, Gergely, Rossi, Christopher, Sinoir, Jeremy, Sorez, Clement, Surr, John, Svensson, Olof, Zander, Ulrich, Cipriani, Florent, Theveneau, Pascal, Mueller-Dieckmann, Christoph · 2018 · Journal of Synchrotron Radiation
Cited by 123

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

ID30B is an undulator-based high-intensity, energy-tuneable (6.0–20 keV) and variable-focus (20–200 µm in diameter) macromolecular crystallography (MX) beamline at the ESRF. It was the last of the ESRF Structural Biology Group's beamlines to be constructed and commissioned as part of the ESRF's Phase I Upgrade Program and has been in user operation since June 2015. Both a modified microdiffractometer (MD2S) incorporating an in situ plate screening capability and a new flexible sample changer (the FlexHCD) were specifically developed for ID30B. Here, the authors provide the current beamline characteristics and detail how different types of MX experiments can be performed on ID30B (http://www.esrf.eu/id30b).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1107/s1600577518007166

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • XDS

    Kabsch, W. (2010) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444909047337 · Cited by 16,463

  • Overview of the CCP 4 suite and current developments

    Winn, M. D., Ballard, C. C., Cowtan, K. D., Dodson, E. J., Emsley, P., Evans, P. R., Keegan, R. M., Krissinel, E. B., Leslie, A. G. W., McCoy, A., et al. (2011) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444910045749 · Cited by 12,353 · cited 1×

    “The structure was further refined using REFMAC (Murshudov et al., 2011), waters added using ARPwarp (Lamzin et al., 2012) and the results visually inspected with Coot (Emsley et al., 2010), all as implemented in CCP4 (Winn et al., 2011).”
    Method

Show all 2 references

Cited by

See all 123

Metadata

Authors
McCarthy, A. A., Barrett, R., Beteva, A., Caserotto, H., Dobias, F., Felisaz, F., Giraud, T., Guijarro, M., Janocha, R., Khadrouche, A., Lentini, M., Leonard, G. A., Lopez Marrero, M., Malbet-Monaco, S., McSweeney, S., Nurizzo, D., Papp, G., Rossi, C., Sinoir, J., Sorez, C., Surr, J., Svensson, O., Zander, U., Cipriani, F., Theveneau, P., & Mueller-Dieckmann, C.
Venue
Journal of Synchrotron Radiation
Published
2018-06-27
Volume
25
Issue
4
Pages
1249-1260
ISSN
  • 0909-0495 (ISSN-L)
  • 1600-5775
OpenAlex
W2810348570
Cited by
123
References
2
FWCI
3.70
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ID30B – a versatile beamline for macromolecular crystallography experiments at the ESRF. https://app.cochat.ai/papers/10.1107/s1600577518007166
The paper
McCarthy, A. A., Barrett, R., Beteva, A., Caserotto, H., Dobias, F., Felisaz, F., Giraud, T., Guijarro, M., Janocha, R., Khadrouche, A., Lentini, M., Leonard, G. A., Lopez Marrero, M., Malbet-Monaco, S., McSweeney, S., Nurizzo, D., Papp, G., Rossi, C., Sinoir, J., . . . Mueller-Dieckmann, C. (2018). ID30B – a versatile beamline for macromolecular crystallography experiments at the ESRF. Journal of Synchrotron Radiation. https://doi.org/10.1107/s1600577518007166

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.