Beamline B21: high-throughput small-angle X-ray scattering at Diamond Light Source
Open accessThe DOI matches its Crossref record.
Abstract
B21 is a small-angle X-ray scattering (SAXS) beamline with a bending magnet source in the 3 GeV storage ring at the Diamond Light Source Ltd synchrotron in the UK. The beamline utilizes a double multi-layer monochromator and a toroidal focusing optic to deliver 2 × 10 12 photons per second to a 34 × 40 µm (FWHM) focal spot at the in-vacuum Eiger 4M (Dectris) detector. A high-performance liquid chromatography system and a liquid-handling robot make it possible to load solution samples into a temperature-controlled in-vacuum sample cell with a high level of automation. Alternatively, a range of viscous or solid materials may be loaded manually using a range of custom sample cells. A default scattering vector range from 0.0026 to 0.34 Å−1 and low instrument background make B21 convenient for measuring a wide range of biological macromolecules. The beamline has run a full user programme since 2013.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Small-angle X-ray and neutron scattering
Jeffries, C. M., Ilavsky, J., Martel, A., Hinrichs, S., Meyer, A., Pedersen, J. S., Sokolova, A. V., & Svergun, D. I. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00064-9 · Cited by 256
Design of a Cereblon construct for crystallographic and biophysical studies of protein degraders
Kroupova, A., Spiteri, V. A., Rutter, Z. J., Furihata, H., Darren, D., Ramachandran, S., Chakraborti, S., Haubrich, K., Pethe, J., Gonzales, D., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-52871-9 · Cited by 47
“SAXS data werecollectedatbeamline B21 at the Diamond Light Source inSEC-SAXScon fi guration(March2023andJune2024) 60 .”
Ballabio, F., Paissoni, C., Bollati, M., de Rosa, M., Capelli, R., & Camilloni, C. (2023) · Journal of Chemical Theory and Computation · doi:10.1021/acs.jctc.3c00864 · Cited by 23
Solution structure and synaptic analyses reveal determinants of bispecific T cell engager potency
Leithner, A., Staufer, O., Mitra, T., Liberta, F., Valvo, S., Kutuzov, M., Dada, H., Spaeth, J., Zhou, W., Schiele, F., et al. (2025) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2425781122 · Cited by 22
Histone divergence in trypanosomes results in unique alterations to nucleosome structure
Deák, G., Wapenaar, H., Sandoval, G., Chen, R., Taylor, M. R. D., Burdett, H., Watson, J. A., Tuijtel, M. W., Webb, S., & Wilson, M. D. (2023) · Nucleic Acids Research · doi:10.1093/nar/gkad577 · Cited by 21
Metadata
- Authors
- Cowieson, N. P., Edwards-Gayle, C. J. C., Inoue, K., Khunti, N. S., Doutch, J., Williams, E., Daniels, S., Preece, G., Krumpa, N. A., Sutter, J. P., Tully, M. D., Terrill, N. J., & Rambo, R. P.
- Venue
- Journal of Synchrotron Radiation
- Published
- 2020-08-18
- Volume
- 27
- Issue
- 5
- Pages
- 1438-1446
- ISSN
- 0909-0495 (ISSN-L)
- 1600-5775
- OpenAlex
- W3063897023
- Cited by
- 177
- References
- 0
- FWCI
- 6.25
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Beamline B21: high-throughput small-angle X-ray scattering at Diamond Light Source. https://app.cochat.ai/papers/10.1107/s1600577520009960
- The paper
- Cowieson, N. P., Edwards-Gayle, C. J. C., Inoue, K., Khunti, N. S., Doutch, J., Williams, E., Daniels, S., Preece, G., Krumpa, N. A., Sutter, J. P., Tully, M. D., Terrill, N. J., & Rambo, R. P. (2020). Beamline B21: high-throughput small-angle X-ray scattering at Diamond Light Source. Journal of Synchrotron Radiation. https://doi.org/10.1107/s1600577520009960
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.