Serial crystallography on in vivo grown microcrystals using synchrotron radiation
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Crystal structure determinations of biological macromolecules are limited by the availability of sufficiently sized crystals and by the fact that crystal quality deteriorates during data collection owing to radiation damage. Exploiting a micrometre-sized X-ray beam, high-precision diffractometry and shutterless data acquisition with a pixel-array detector, a strategy for collecting data from many micrometre-sized crystals presented to an X-ray beam in a vitrified suspension is demonstrated. By combining diffraction data from 80 Trypanosoma brucei procathepsin B crystals with an average volume of 9 µm 3, a complete data set to 3.0 Å resolution has been assembled. The data allowed the refinement of a structural model that is consistent with that previously obtained using free-electron laser radiation, providing mutual validation. Further improvements of the serial synchrotron crystallography technique and its combination with serial femtosecond crystallography are discussed that may allow the determination of high-resolution structures of micrometre-sized crystals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phaser crystallographic software
McCoy, A. J., Grosse-Kunstleve, R. W., Adams, P. D., Winn, M. D., Storoni, L. C., & Read, R. J. (2007) · Journal of Applied Crystallography · doi:10.1107/s0021889807021206 · Cited by 20,612
Kabsch, W. (2010) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444909047337 · Cited by 16,463
Crystal structure of the β2 adrenergic receptor–Gs protein complex
Rasmussen, S. G. F., DeVree, B. T., Zou, Y., Kruse, A. C., Chung, K. Y., Kobilka, T. S., Thian, F. S., Chae, P. S., Pardon, E., Calinski, D., et al. (2011) · Nature · doi:10.1038/nature10361 · Cited by 3,009 · cited 2×
“…polyhedra protein (Coulibaly et al., 2007), amyloid-like fibres (Nelson et al., 2005) and a number of complexes addressing the structure and function of G-protein-coupled receptors (GPCRs; Cherezov et al., 2007; Rasmussen et al., 2007, 2011) have been determined from micrometre-sized crystals.”
BackgroundPotential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022 · cited 1×
“Referred to as ‘diffraction before destruction’, the inertia of the atoms prevents significant atomic displacement during the short exposing pulse (Neutze et al., 2000; Boutet et al., 2012; Barty et al., 2012), even though the initial photoabsorption eventually leads to plasma formation and the…”
BackgroundLinking Crystallographic Model and Data Quality
Karplus, P. A., & Diederichs, K. (2012) · Science · doi:10.1126/science.1218231 · Cited by 1,781
Natively Inhibited Trypanosoma brucei Cathepsin B Structure Determined by Using an X-ray Laser
Redecke, L., Nass, K., DePonte, D. P., White, T. A., Rehders, D., Barty, A., Stellato, F., Liang, M., Barends, T. R. M., Boutet, S., et al. (2013) · Science · doi:10.1126/science.1229663 · Cited by 440 · cited 8×
“…procathepsin B structure solved in this study at 110 K using synchrotron radiation with that previously obtained at room temperature using the FEL-based SFX technique (PDB entry 4hwy; Redecke et al., 2013), electron-density maps were generated using the SFX data truncated at 3.0 Å resolution.”
BackgroundMethodInfluentialSelf-citation
Cited by
DIALS: implementation and evaluation of a new integration package
Winter, G., Waterman, D. G., Parkhurst, J. M., Brewster, A. S., Gildea, R. J., Gerstel, M., Fuentes-Montero, L., Vollmar, M., Michels-Clark, T., Young, I. D., et al. (2018) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798317017235 · Cited by 1,115
Linac Coherent Light Source: The first five years
Bostedt, C., Boutet, S., Fritz, D. M., Huang, Z., Lee, H. J., Lemke, H. T., Robert, A., Schlotter, W. F., Turner, J. J., & Williams, G. J. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.015007 · Cited by 618
Serial femtosecond crystallography: the first five years
Schlichting, I. (2015) · IUCrJ · doi:10.1107/s205225251402702x · Cited by 308
Room-temperature macromolecular serial crystallography using synchrotron radiation
Stellato, F., Oberthür, D., Liang, M., Bean, R., Gati, C., Yefanov, O., Barty, A., Burkhardt, A., Fischer, P., Galli, L., et al. (2014) · IUCrJ · doi:10.1107/s2052252514010070 · Cited by 256
Self-citationThe hit-and-return system enables efficient time-resolved serial synchrotron crystallography
Schulz, E. C., Mehrabi, P., Müller-Werkmeister, H. M., Tellkamp, F., Jha, A., Stuart, W., Persch, E., De Gasparo, R., Diederich, F., Pai, E. F., et al. (2018) · Nature Methods · doi:10.1038/s41592-018-0180-2 · Cited by 111
Metadata
- Authors
- Gati, C., Bourenkov, G., Klinge, M., Rehders, D., Stellato, F., Oberthür, D., Yefanov, O., Sommer, B. P., Mogk, S., Duszenko, M., Betzel, C., Schneider, T. R., Chapman, H. N., & Redecke, L.
- Venue
- IUCrJ
- Published
- 2014-02-10
- Volume
- 1
- Issue
- 2
- Pages
- 87-94
- ISSN
- 2052-2525 (ISSN-L)
- OpenAlex
- W2144625174
- Cited by
- 226
- References
- 6
- FWCI
- 14.44
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.