Approaches to altering particle distributions in cryo-electron microscopy sample preparation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Cryo-electron microscopy (cryo-EM) can now be used to determine high-resolution structural information on a diverse range of biological specimens. Recent advances have been driven primarily by developments in microscopes and detectors, and through advances in image-processing software. However, for many single-particle cryo-EM projects, major bottlenecks currently remain at the sample-preparation stage; obtaining cryo-EM grids of sufficient quality for high-resolution single-particle analysis can require the careful optimization of many variables. Common hurdles to overcome include problems associated with the sample itself (buffer components, labile complexes), sample distribution (obtaining the correct concentration, affinity for the support film), preferred orientation, and poor reproducibility of the grid-making process within and between batches. This review outlines a number of methodologies used within the electron-microscopy community to address these challenges, providing a range of approaches which may aid in obtaining optimal grids for high-resolution data collection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cryo-EM structures of tau filaments from Alzheimer’s disease
Fitzpatrick, A. W. P., Falcon, B., He, S., Murzin, A. G., Murshudov, G., Garringer, H. J., Crowther, R. A., Ghetti, B., Goedert, M., & Scheres, S. H. W. (2017) · Nature · doi:10.1038/nature23002 · Cited by 2,061 · cited 1×
“…in the electron-microscopy (EM) field, with a rapid expansion in the use of single-particle approaches to determine high-resolution structures, including those of macromolecular complexes, membrane proteins and ribosomes (Nguyen et al., 2015; Fitzpatrick et al., 2017; Plaschka et al., 2017).”
Background
Cited by
Challenges and opportunities in cryo-EM single-particle analysis
Lyumkis, D. (2019) · Journal of Biological Chemistry · doi:10.1074/jbc.rev118.005602 · Cited by 356
Understanding the invisible hands of sample preparation for cryo-EM
Weissenberger, G., Henderikx, R. J. M., & Peters, P. J. (2021) · Nature Methods · doi:10.1038/s41592-021-01130-6 · Cited by 181
Zhang, H., Zheng, D., Wu, Q., Yan, N., Peng, H., Hu, Q., Peng, Y., Yan, Z., Shi, Z., Bao, C., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-59797-w · Cited by 12
Structural mechanism of CRL4‐instructed STAT2 degradation via a novel cytomegaloviral DCAF receptor
Le‐Trilling, V. T. K., Banchenko, S., Paydar, D., Leipe, P. M., Binting, L., Lauer, S., Graziadei, A., Klingen, R., Gotthold, C., Bürger, J., et al. (2023) · The EMBO Journal · doi:10.15252/embj.2022112351 · Cited by 10
Structure and mechanism of a novel cytomegaloviral DCAF mediating interferon antagonism
(2022) · doi:10.1101/2022.05.05.490734 · Cited by 10
Metadata
- Authors
- Drulyte, I., Johnson, R. M., Hesketh, E. L., Hurdiss, D. L., Scarff, C. A., Porav, S. A., Ranson, N. A., Muench, S. P., & Thompson, R. F.
- Venue
- Acta Crystallographica Section D Structural Biology
- Published
- 2018-05-18
- Volume
- 74
- Issue
- 6
- Pages
- 560-571
- ISSN
- 2059-7983 (ISSN-L)
- OpenAlex
- W2804636455
- Cited by
- 148
- References
- 1
- FWCI
- 7.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.