Inertial sensors for motion detection of human upper limbs
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Purpose: This paper seeks to present an inertial motion tracking system for monitoring movements of human upper limbs in order to support a home‐based rehabilitation scheme in which the recovery of stroke patients' motor function through repetitive exercises needs to be continuously monitored and appropriately evaluated. Design/methodology/approach: Two inertial sensors are placed on the upper and lower arms in order to obtain acceleration and turning rates. Then the position of the upper limbs can be deduced by using the kinematical model of the upper limbs that was designed in the previous paper. The tracking system starts from inertial data acquisition and pre‐filtering, followed by a number of processes such as transformation of coordinate systems of sensor data, and kinematical modelling and optimization of position estimation. Findings: The motion detector using the proposed kinematic model only has drifts in the measurements. Fusion of acceleration and orientation data can effectively solve the drift problem without the involvement of a Kalman filter. Research limitations/implications: The image rendering is not undertaken when the data sampling is performed. This non‐synchronization is applied in order to avoid the breaks in the continuous sampling. Originality/value: This new motion detector can work in different environments without significant drifts. Also, this system only deploys two inertial sensors but is able to estimate the position of the wrist, elbow and shoulder joints.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813
Self-citationInertial measurements of upper limb motion
Zhou, H., Hu, H., & Tao, Y. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0063-z · Cited by 106 · cited 9×
“The main concern of our motion detection analysis is the orientation estimate that can be fed into the proposed kinematic model (Zhou et al., 2006c).”
BackgroundMethodInfluentialSelf-citation
Cited by
Human motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813
Self-citationSensors for daily life: A review
Javaid, M., Haleem, A., Rab, S., Pratap Singh, R., & Suman, R. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100121 · Cited by 430
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369
Evaluation of Validity and Reliability of Inertial Measurement Unit-Based Gait Analysis Systems
Cho, Y.-S., Jang, S.-H., Cho, J.-S., Kim, M.-J., Lee, H. D., Lee, S. Y., & Moon, S.-B. (2018) · Annals of Rehabilitation Medicine · doi:10.5535/arm.2018.42.6.872 · Cited by 132
Metadata
- Authors
- Zhou, H., & Hu, H.
- Venue
- Sensor Review
- Publisher
- Emerald
- Published
- 2007-04-03
- Volume
- 27
- Issue
- 2
- Pages
- 151-158
- ISSN
- 0260-2288 (ISSN-L)
- OpenAlex
- W2077082540
- Cited by
- 56
- References
- 2
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inertial sensors for motion detection of human upper limbs. https://app.cochat.ai/papers/10.1108/02602280710731713
- The paper
- Zhou, H., & Hu, H. (2007). Inertial sensors for motion detection of human upper limbs. Sensor Review. https://doi.org/10.1108/02602280710731713
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.