CoChat

Inertial measurements of upper limb motion

Zhou, Huiyu, Hu, Huosheng, Tao, Yaqin · 2006 · Medical & Biological Engineering & Computing

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

We present an inertial sensor based monitoring system for measuring upper limb movements in real time. The purpose of this study is to develop a motion tracking device that can be integrated within a home-based rehabilitation system for stroke patients. Human upper limbs are represented by a kinematic chain in which there are four joint variables to be considered: three for the shoulder joint and one for the elbow joint. Kinematic models are built to estimate upper limb motion in 3-D, based on the inertial measurements of the wrist motion. An efficient simulated annealing optimisation method is proposed to reduce errors in estimates. Experimental results demonstrate the proposed system has less than 5% errors in most motion manners, compared to a standard motion tracker.

Overview

Integrity signals

Registry

Crossref · 10.1007/s11517-006-0063-z

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 15 references

Research works printed but not linked: 1

  1. Zhou H, Hu H (2005) Inertial motion tracking of human arm movements in home-based rehabilitation. In: Proceedings of IEEE international conference on mechatronics and automation, Niagara Falls, Ontario, Canada, pp 1306–1311

Cited by

See all 110

Metadata

Authors
Zhou, H., Hu, H., & Tao, Y.
Affiliations
University of Essex (GB)
Corresponding author
Zhou, Huiyu
Venue
Medical & Biological Engineering & Computing
Published
2006-05-31
Volume
44
Issue
6
Pages
479-487
ISSN
  • 0140-0118 (ISSN-L)
  • 1741-0444
OpenAlex
W2126821206
Cited by
106
References
15
Citations by year
2026: 1 · 2025: 2 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 10 · 2019: 6 · 2018: 5 · 2017: 7 · 2016: 4 · 2015: 9 · 2014: 7 · 2013: 8 · 2012: 6
FWCI
7.47
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Medical & Biological Engineering & Computing (publishedVersion)
  • PubMed (publishedVersion)
  • Research Portal (Queen's University Belfast) (submittedVersion)
Funders
Engineering and Physical Sciences Research Council (GR/S29089/01)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
Keywords
inertial sensors, stroke rehabilitation, home-based rehabilitation, kinematic modeling, wrist kinematics, shoulder joint, elbow, simulated annealing, 3D motion estimation, real-time motion monitoring
MeSH terms
Stroke Rehabilitation, Biomechanical Phenomena, Elbow Joint, Equipment Design, Humans, Male, Models, Biological, Motion, Wrist Joint, Range of Motion, Articular, Stroke, Upper Extremity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inertial measurements of upper limb motion. https://app.cochat.ai/papers/10.1007/s11517-006-0063-z
The paper
Zhou, H., Hu, H., & Tao, Y. (2006). Inertial measurements of upper limb motion. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-006-0063-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.