Design and performance of metal conductors for stretchable electronic circuits
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose: The purpose of this paper is to present an update on the progress of the design and reliability of stretchable interconnections for electronic circuits. Design/methodology/approach: Finite element modelling (FEM) is used to analyse the physical behaviour of stretchable interconnects under different loading conditions. The fatigue life of a copper interconnect embedded into a silicone matrix has been evaluated using the Coffin‐Manson relation and FEM. Findings: The mechanical properties of the substrate and the design of the metal interconnection play an important role on the fatigue lifetime of circuit. In the case of copper embedded into a PDMS Sylgard 186, more than 2,500 tensile cycles have been observed for a periodic deformation of 10 per cent. Research limitations/implications: Reliability results are limited and need further work to create a more accurate empirical model to estimate the lifetime of stretchable interconnections. Originality/value: The combined use of FEM and experimental analysis enable a more reliable design of the stretchable metal interconnections. The proposed horseshoe design offers the benefit of reduced permanent damage during elongation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A flexible and wearable glucose sensor based on functional polymers with Soft-MEMS techniques
Kudo, H., Sawada, T., Kazawa, E., Yoshida, H., Iwasaki, Y., & Mitsubayashi, K. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.05.006 · Cited by 255
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Nature-Inspired Structural Materials for Flexible Electronic Devices
Liu, Y., He, K., Chen, G., Leow, W. R., & Chen, X. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00291 · Cited by 798
Tissue–electronics interfaces: from implantable devices to engineered tissues
Feiner, R., & Dvir, T. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.76 · Cited by 595
Review of Flexible Temperature Sensing Networks for Wearable Physiological Monitoring
Li, Q., Zhang, L., Tao, X., & Ding, X. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601371 · Cited by 354
Zhang, Y., Wang, S., Li, X., Fan, J. A., Xu, S., Song, Y. M., Choi, K., Yeo, W., Lee, W., Nazaar, S. N., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201302957 · Cited by 354
Metadata
- Authors
- Gonzalez, M., Axisa, F., Bossuyt, F., Hsu, Y., Vandevelde, B., & Vanfleteren, J.
- Venue
- Circuit World
- Publisher
- Emerald
- Published
- 2009-02-06
- Volume
- 35
- Issue
- 1
- Pages
- 22-29
- ISSN
- 0305-6120 (ISSN-L)
- OpenAlex
- W2118300133
- Cited by
- 68
- References
- 1
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and performance of metal conductors for stretchable electronic circuits. https://app.cochat.ai/papers/10.1108/03056120910928699
- The paper
- Gonzalez, M., Axisa, F., Bossuyt, F., Hsu, Y., Vandevelde, B., & Vanfleteren, J. (2009). Design and performance of metal conductors for stretchable electronic circuits. Circuit World. https://doi.org/10.1108/03056120910928699
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.