The DOI matches its Crossref record.
Effect of process parameters on the morphological and mechanical properties of 3D Bioextruded poly(ε‐caprolactone) scaffolds
Abstract
Purpose: This paper aims to report a detailed study regarding the influence of process parameters on the morphological/mechanical properties of poly(ε‐caprolactone) (PCL) scaffolds manufactured by using a novel extrusion‐based system that is called BioExtruder. Design/methodology/approach: In this study the authors focused investigations on four parameters, namely the liquefier temperature (LT), screw rotation velocity (SRV), deposition velocity (DV) and slice thickness (ST). Scaffolds were fabricated by employing three different values of each parameter. Through a series of trials, scaffolds were manufactured varying iteratively one parameter while maintaining constant the other ones. The morphology of the structures was investigated using a scanning electron microscope (SEM), whilst the mechanical performance was assessed though compression tests. Findings: Experimental results highlight a direct influence of the process parameters on the PCL scaffolds properties. In particular, DV and SRV have the highest influence in terms of road width (RW) and consequently on the porosity and mechanical behaviour of the structures. Research limitations/implications: The effect of process and design parameters on the biological response of scaffolds is currently under investigation. Originality/value: The output of this work provides a major insight into the effect of process parameters on the morphological/mechanical properties of PCL scaffolds. Moreover, the potential and feasibility of this novel extrusion‐based system open a new opportunity to study how structural features may influence the characteristics and performances of the scaffolds, enabling the development of integrated biomechanical models that can be used in CAD systems to manufacture customized structures for tissue regeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fused deposition modeling with polypropylene
Carneiro, O. S., Silva, A. F., & Gomes, R. (2015) · Materials & Design · doi:10.1016/j.matdes.2015.06.053 · Cited by 851
Vaezi, M., Chianrabutra, S., Mellor, B., & Yang, S. (2013) · Virtual and Physical Prototyping · doi:10.1080/17452759.2013.778175 · Cited by 548
Melt electrospinning today: An opportune time for an emerging polymer process
Brown, T. D., Dalton, P. D., & Hutmacher, D. W. (2016) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2016.01.001 · Cited by 542
Vascularized 3D printed scaffolds for promoting bone regeneration
Yan, Y., Chen, H., Zhang, H., Guo, C., Yang, K., Chen, K., Cheng, R., Qian, N., Sandler, N., Zhang, Y. S., et al. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.10.033 · Cited by 475
Additive manufacturing techniques for the production of tissue engineering constructs
Mota, C., Puppi, D., Chiellini, F., & Chiellini, E. (2015) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.1635 · Cited by 382
Self-citation
Metadata
- Authors
- Domingos, M., Chiellini, F., Gloria, A., Ambrosio, L., Bartolo, P., & Chiellini, E.
- Venue
- Rapid Prototyping Journal
- Publisher
- Emerald
- Published
- 2012-01-13
- Volume
- 18
- Issue
- 1
- Pages
- 56-67
- ISSN
- 1355-2546 (ISSN-L)
- OpenAlex
- W2035399778
- Cited by
- 164
- References
- 0
- FWCI
- 23.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of process parameters on the morphological and mechanical properties of 3D Bioextruded poly(ε‐caprolactone) scaffolds. https://app.cochat.ai/papers/10.1108/13552541211193502
- The paper
- Domingos, M., Chiellini, F., Gloria, A., Ambrosio, L., Bartolo, P., & Chiellini, E. (2012). Effect of process parameters on the morphological and mechanical properties of 3D Bioextruded poly(ε‐caprolactone) scaffolds. Rapid Prototyping Journal. https://doi.org/10.1108/13552541211193502
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.