CoChat

Effect of process parameters settings and thickness on surface roughness of EBM produced Ti‐6Al‐4V

Safdar, A., He, H.Z., Wei, Liu‐Ying, Snis, A., Chavez de Paz, Luis E. · 2012 · Rapid Prototyping Journal
Cited by 214

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Purpose – Ti-6Al-4V is one of the most attractive materials being used in aerospace, automotive and medical implant industries. Electron beam melting (EBM) is one of the direct digital manufacturing methods to produce complex geometries of fully dense and near net shape parts. The EBM system provides an opportunity to built metallic objects with different processing parameter settings like beam current, scan speed, probe size on powder, etc. The purpose of this paper is to determine and understand the effect of part's thickness and variation in process parameter settings of the EBM system on surface roughness/topography of EBM fabricated Ti-6Al-4V metallic parts. \n \nDesign/methodology/approach – A mathematical model based upon response surface methodology (RSM) is developed to study the variation of surface roughness with changing process parameter settings. Surface roughness of the test slabs produced with different parameter settings and thickness has been studied under confocal microscope. Response surface methodology was used to develop a multiple regression model to correlate the effect of variation in EBM process parameters settings and thickness of parts on surface roughness of EBM produced Ti-6Al-4V. \n \nFindings – It has been observed that every part produced by EBM system has detectable surface roughness. The surface roughness parameter Ra varies between 1-20 µm for different samples depending upon the process parameter setting and thickness. The Ra value increases with increasing sample thickness and beam current, and decreases with increase in offset focus and scan speed. \n \nOriginality/value – Surface roughness is related to wear and friction property of the material and hence is related to the life time and performance of the part. Surface roughness is an important property of any material to be considered as biomaterial. The surface roughness of the material depends upon the manufacturing method and environment and hence it is controllable either during fabrication or by post processing. From the 1st order regression model developed in this study, it is also evident that sample thickness, scan speed and beam current have relatively more effect on roughness value then the offset focus. With the model obtained equation, a designer can subsequently select the best combination of sample thickness and process parameter values to achieve desired surface roughness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1108/13552541211250391

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 214

Metadata

Authors
Safdar, A., He, H. Z., Wei, L., Snis, A., & Chavez de Paz, L. E.
Venue
Rapid Prototyping Journal
Publisher
Emerald
Published
2012-07-27
Volume
18
Issue
5
Pages
401-408
ISSN
1355-2546 (ISSN-L)
OpenAlex
W1989716051
Cited by
214
References
10
FWCI
3.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.