The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Neural-network-based adaptive matched filtering for QRS detection
Abstract
We have developed an adaptive matched filtering algorithm based upon an artificial neural network (ANN) for QRS detection. We use an ANN adaptive whitening filter to model the lower frequencies of the ECG which are inherently nonlinear and nonstationary. The residual signal which contains mostly higher frequency QRS complex energy is then passed through a linear matched filter to detect the location of the QRS complex. We developed an algorithm to adaptively update the matched filter template from the detected QRS complex in the ECG signal itself so that the template can be customized to an individual subject. This ANN whitening filter is very effective at removing the time-varying, nonlinear noise characteristic of ECG signals. Using this novel approach, the detection rate for a very noisy patient record in the MIT/BIH arrhythmia database is 99.5%, which compares favorably to the 97.5% obtained using a linear adaptive whitening filter and the 96.5% achieved with a bandpass filtering method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probability, Random Variables, and Stochastic Processes.
Abrahams, J., & Papoulis, A. (1984) · Journal of the American Statistical Association · doi:10.2307/2288754 · Cited by 16,226
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Self-citationAn introduction to computing with neural nets
Lippmann, R. (1987) · IEEE ASSP Magazine · doi:10.1109/massp.1987.1165576 · Cited by 7,825
(1991) · Springer eBooks · doi:10.1007/978-3-7091-2840-4 · Cited by 5,095
Alexander, S. T. (1986) · Springer eBooks · doi:10.1007/978-1-4612-4978-8 · Cited by 2,646
Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database
Hamilton, P. S., & Tompkins, W. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325695 · Cited by 1,142
Self-citationProakis, J. (1975) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1975.1162707 · Cited by 826
PREDICTING THE FUTURE: A CONNECTIONIST APPROACH
Weigend, A. S., Huberman, B. A., & Rumelhart, D. E. (1990) · International Journal of Neural Systems · doi:10.1142/s0129065790000102 · Cited by 721
Comparing Biases for Minimal Network Construction with Back-Propagation
Hanson, S. J., & Pratt, L. (1988) · neural information processing systems · Cited by 480
Neural net pruning-why and how
Sietsma, & Dow (1988) · IEEE International Conference on Neural Networks · doi:10.1109/icnn.1988.23864 · Cited by 232
A Back-Propagation Algorithm with Optimal Use of Hidden Units
Chauvin, Y. (1988) · neural information processing systems · Cited by 168
Adaptive QRS Detection Based on Maximum A Posteriori Estimation
Börjesson, P. O., Pahlm, O., Sörnmo, L., & Nygårds, M. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324901 · Cited by 64
Using a translation-invariant neural network to diagnose heart arrhythmia
Lee, S. C. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1989.96577 · Cited by 32
Dimensionality Reduction and Prior Knowledge in E-Set Recognition
Lang, K., & Hinton, G. E. (1989) · neural information processing systems · Cited by 31
Cited by
Detection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597
The principles of software QRS detection
Kohler, B.-U., Hennig, C., & Orglmeister, R. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.993193 · Cited by 1,242
ECG-based heartbeat classification for arrhythmia detection: A survey
Luz, E. J. D. S., Schwartz, W. R., Cámara-Chávez, G., & Menotti, D. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.12.008 · Cited by 878
The use of the Hilbert transform in ECG signal analysis
Benitez, D., Gaydecki, P. A., Zaidi, A., & Fitzpatrick, A. P. (2001) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(01)00009-9 · Cited by 489
An Efficient Algorithm for Automatic Peak Detection in Noisy Periodic and Quasi-Periodic Signals
Scholkmann, F., Boss, J., & Wolf, M. (2012) · Algorithms · doi:10.3390/a5040588 · Cited by 453
Metadata
- Authors
- Xue, Q., Hu, Y. H., & Tompkins, W. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1992-04
- Volume
- 39
- Issue
- 4
- Pages
- 317-329
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2117911070
- Cited by
- 423
- References
- 14
- FWCI
- 3.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.