Simple photon diffusion analysis of the effects of multiple scattering on pulse oximetry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Photon diffusion theory is used to derive analytical expressions that relate the ac-dc intensity ratios measured by transmission-mode and reflectance-mode pulse oximeters to arterial oxygen saturation (SaO2). The effects of multiple scattering are examined by comparing the results of the photon diffusion analysis with those obtained using an analysis based on the Beer-Lambert law which neglects scattering. We show that the difference between the average lengths of the paths travelled by red and infrared photons makes the calibration curve of oximeters sensitive to the total attenuation coefficients of the tissue in the two wavelength bands, as well as to absorption by the pulsating arterial blood. Therefore, the shape of the calibration curve is affected by tissue blood volume, source-detector placement, and other variables that change the wavelength dependence of the attenuation coefficient of the tissue. After evaluating the relationship between SaO2 and the red/IR ac-dc ratio (R) under a variety of physiological conditions, we conclude that, for oximeters utilizing fixed calibration curves based on measurements obtained from normal subjects, errors introduced by interfering variables should be less than a few percent when SaO2 exceeds 70%. Predicted errors at lower oxygen saturation values are substantially greater because R is much more sensitive to interfering variables in this measurement range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Cited by
Imaging the body with diffuse optical tomography
Boas, D. A., Brooks, D. H., Miller, E. L., DiMarzio, C. A., Kilmer, M., Gaudette, R. J., & Zhang, Q. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962278 · Cited by 718
Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations
Chan, E. D., Chan, M. M., & Chan, M. M. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2013.02.004 · Cited by 710
Boas, D. A., & Yodh, A. G. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000192 · Cited by 606
Diffuse reflectance spectroscopy of human adenomatous colon polyps in vivo
Zonios, G., Perelman, L. T., Backman, V., Manoharan, R., Fitzmaurice, M., Van Dam, J., & Feld, M. S. (1999) · Applied Optics · doi:10.1364/ao.38.006628 · Cited by 534
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 366
Metadata
- Authors
- Schmitt, J. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1991
- Volume
- 38
- Issue
- 12
- Pages
- 1194-1203
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2123295456
- Cited by
- 118
- References
- 1
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simple photon diffusion analysis of the effects of multiple scattering on pulse oximetry. https://app.cochat.ai/papers/10.1109/10.137285
- The paper
- Schmitt, J. M. (1991). Simple photon diffusion analysis of the effects of multiple scattering on pulse oximetry. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.137285
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.