Simple photon diffusion analysis of the effects of multiple scattering on pulse oximetry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Photon diffusion theory is used to derive analytical expressions that relate the ac-dc intensity ratios measured by transmission-mode and reflectance-mode pulse oximeters to arterial oxygen saturation (SaO2). The effects of multiple scattering are examined by comparing the results of the photon diffusion analysis with those obtained using an analysis based on the Beer-Lambert law which neglects scattering. We show that the difference between the average lengths of the paths travelled by red and infrared photons makes the calibration curve of oximeters sensitive to the total attenuation coefficients of the tissue in the two wavelength bands, as well as to absorption by the pulsating arterial blood. Therefore, the shape of the calibration curve is affected by tissue blood volume, source-detector placement, and other variables that change the wavelength dependence of the attenuation coefficient of the tissue. After evaluating the relationship between SaO2 and the red/IR ac-dc ratio (R) under a variety of physiological conditions, we conclude that, for oximeters utilizing fixed calibration curves based on measurements obtained from normal subjects, errors introduced by interfering variables should be less than a few percent when SaO2 exceeds 70%. Predicted errors at lower oxygen saturation values are substantially greater because R is much more sensitive to interfering variables in this measurement range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Cited by
Imaging the body with diffuse optical tomography
Boas, D. A., Brooks, D. H., Miller, E. L., DiMarzio, C. A., Kilmer, M., Gaudette, R. J., & Zhang, Q. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962278 · Cited by 718
Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations
Chan, E. D., Chan, M. M., & Chan, M. M. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2013.02.004 · Cited by 710
Boas, D. A., & Yodh, A. G. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000192 · Cited by 606
Diffuse reflectance spectroscopy of human adenomatous colon polyps in vivo
Zonios, G., Perelman, L. T., Backman, V., Manoharan, R., Fitzmaurice, M., Van Dam, J., & Feld, M. S. (1999) · Applied Optics · doi:10.1364/ao.38.006628 · Cited by 534
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 366
Miniaturized Battery‐Free Wireless Systems for Wearable Pulse Oximetry
Kim, J., Gutruf, P., Chiarelli, A. M., Heo, S. Y., Cho, K., Xie, Z., Banks, A., Han, S., Jang, K., Lee, J. W., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201604373 · Cited by 334
Alian, A. A., & Shelley, K. H. (2014) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2014.08.006 · Cited by 289
Zonios, G., & Dimou, A. (2006) · Optics Express · doi:10.1364/oe.14.008661 · Cited by 196
The Light–Tissue Interaction of Pulse Oximetry
Mannheimer, P. D. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269522.84942.54 · Cited by 194
Fabrication and in vitro deployment of a laser-activated shape memory polymer vascular stent
Baer, G. M., Small, W., Wilson, T. S., Benett, W. J., Matthews, D. L., Hartman, J., & Maitland, D. J. (2007) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-6-43 · Cited by 159
“Due to their different values of absorption coefficient (µa) near the laser wavelength of 810 nm, photothermal actuation of the stent will proceed differently in water (µ a = 0.0021 mm-1 [34]) than blood (µa = 0.466 mm-1 [ 35 ]).”
BackgroundInfluentialChatterjee, S., & Kyriacou, P. A. (2019) · Sensors · doi:10.3390/s19040789 · Cited by 86
“Considering the absorbance of light through arterial and venous blood with different concentrations of the absorbers oxyhaemoglobin (HbO2) and deoxyhaemoglobin (HHb), the total absorption coefficient of any i-th dermal sublayer can be written as: [14,23,32]”
BackgroundAn Efficient Motion-Resistant Method for Wearable Pulse Oximeter
Yan, Y.-S., & Zhang, Y.-T. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.902173 · Cited by 62
Rafolt, D., & Gallasch, E. (2004) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2004.005 · Cited by 19
Nijland, R., Jongsma, H. W., Verbruggen, I. M., & Nijhuis, J. G. (1996) · Journal of Clinical Monitoring · doi:10.1007/bf00857643 · Cited by 8
Metadata
- Authors
- Schmitt, J. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1991
- Volume
- 38
- Issue
- 12
- Pages
- 1194-1203
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2123295456
- Cited by
- 118
- References
- 1
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.