Modeling the neuron-microtransducer junction: from extracellular to patch recording
The DOI matches its Crossref record.
Abstract
This paper is devoted to a detailed characterization of the neuron-to-microtransducer junction, based on the equivalent electric-circuit approach. As a result, recording of action potentials can be simulated with the general-purpose network-analysis program SPICE. Both noble-metal microelectrodes and insulated-gate FET's are considered. The responses of such devices are characterized as functions of several parameters, e.g., sealing impedance, density of ionic currents in the cell membrane, and spatial discontinuities of the adhesion process. It is shown that the various signal shapes reported in the literature can be reproduced and interpreted in terms of time derivatives of the action potential. In this way, the shape of any experimental signal can be interpreted on the basis of a specific sealing condition. Possible future improvements in microtransducer design, based on the proposed approach, are also suggested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
“Later, this concept has been adapted for substrate integrated MEA devices, e.g., to compare metal micro-electrodes with OGFET devices in simulations (Grattarola and Martinoia, 1993).”
Recent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
Encyclopedia of Applied Electrochemistry
(2014) · Springer eBooks · doi:10.1007/978-1-4419-6996-5 · Cited by 482
Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants
Williams, J. C., Hippensteel, J. A., Dilgen, J., Shain, W., & Kipke, D. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/007 · Cited by 399
Mazzatenta, A., Giugliano, M., Campidelli, S., Gambazzi, L., Businaro, L., Markram, H., Prato, M., & Ballerini, L. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.1051-07.2007 · Cited by 349
Metadata
- Authors
- Grattarola, M., & Martinoia, S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1993
- Volume
- 40
- Issue
- 1
- Pages
- 35-41
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2105899130
- Cited by
- 95
- References
- 0
- FWCI
- 0.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modeling the neuron-microtransducer junction: from extracellular to patch recording. https://app.cochat.ai/papers/10.1109/10.204769
- The paper
- Grattarola, M., & Martinoia, S. (1993). Modeling the neuron-microtransducer junction: from extracellular to patch recording. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.204769
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.