The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Simultaneous measurement of intracellular calcium and electrical activity from patterned neural networks in culture
Abstract
Multisite extracellular electrical activity and intracellular calcium were recorded simultaneously. Electrical signals were measured using microelectrode array substrates. A novel cell positioning technique was combined with a method for controlling neurite outgrowth, which allowed cell-electrode contacts to be established easily, thus facilitating the electrical recording. Intracellular calcium was measured optically using the indicator fluo 3. Under low-magnesium conditions, cultured rat cortical neurons showed periodic transients of fluo-3 fluorescence, which were synchronized with the periodic bursting observed electrically. The intervals between bursts could be determined by electrical stimulation through the substrate electrodes. The results suggest that functional synaptic connections are formed in the culture system.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Having surface topologies on the substrate, axonal outgrowth of embryonic nerve cells from rats was observed and electrical activity was recorded in a microstructure with 16 electrodes that were connected with grooves (Jimbo and Kawana, 1992; Jimbo et al., 1993)”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Jimbo et al., 1993
Citations
Cites
Electrical stimulation and recording from cultured neurons using a planar electrode array
Jimbo, Y., & Kawana, A. (1992) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(92)80067-q · Cited by 126
Self-citationDroge, M., Gross, G., Hightower, M., & Czisny, L. (1986) · The Journal of Neuroscience · doi:10.1523/jneurosci.06-06-01583.1986 · Cited by 109
Research works printed but not linked: 20
- 10.1109/IEMBS.1990.691994 · DOI
- 10.1242/jcs.1987.Supplement_8.4 · DOI
- 10.1016/0006-8993(88)91314-5 · DOI
- 10.1002/neu.480210110 · DOI
- 10.1002/jnr.490130115 · DOI
- kleinfeld, 1988, Controlled outgrowth of dissociated neurons on patterned substrates, J Neurosci, 8, 4098, 10.1523/JNEUROSCI.08-11-04098.1988 · DOI
- 10.1016/0165-3806(90)90265-Z · DOI
- 10.1016/0165-0270(85)90105-0 · DOI
- minta, 1989, Fluorescent indicators for cytosolic calcium based on rhodamine and fluorescein chromophores, J Biol Chem, 264, 8171, 10.1016/S0021-9258(18)83165-9 · DOI
- 10.1109/TBME.1979.326402 · DOI
- 10.1109/10.7273 · DOI
- 10.1016/0165-0270(88)90187-2 · DOI
- 10.1016/0165-0270(80)90042-4 · DOI
- 10.1109/10.102802 · DOI
- 10.1016/S0166-2236(84)80125-3 · DOI
- tsien, 1989, Methods in Cell Biology, 30, 127, 10.1016/S0091-679X(08)60978-4 · DOI
- 10.1016/0165-0270(89)90055-1 · DOI
- fromhcrz, 1991, A neuron-silicon junction: A retzius cell of the leech on an insulated-gate field-effect transistor, Science, 252, 1290, 10.1126/science.1925540 · DOI
- 10.2183/pjab.64.319 · DOI
- 10.1016/0304-3940(87)90563-5 · DOI
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
“Having surface topologies on the substrate, axonal outgrowth of embryonic nerve cells from rats was observed and electrical activity was recorded in a microstructure with 16 electrodes that were connected with grooves (Jimbo and Kawana, 1992; Jimbo et al., 1993).”
MethodMicroengineering of Cellular Interactions
Folch, A., & Toner, M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.227 · Cited by 602
“Jimbo et al (37) selectively seeded rat cortical neurons (from 18-day embryos) on transparent, indium-tin oxide microelectrodes on glass by using a stainless steel stencil containing 130-µmdiameter holes aligned in registration with the indium-tin oxide microelectrodes.”
BackgroundMethodInfluentialIntegration of Cell Culture and Microfabrication Technology
Park, T., & Shuler, M. (2003) · Biotechnology progress (Print) · doi:10.1021/bp020143k · Cited by 495
Maeda, E., Robinson, H., & Kawana, A. (1995) · Journal of Neuroscience · doi:10.1523/jneurosci.15-10-06834.1995 · Cited by 367
“Planar electrode arrays (PEAS) were fabricated by a method similar to that described in Jimbo et al. (1993).”
MethodSelf-citationSynthetic nano-fibrillar extracellular matrices with predesigned macroporous architectures
Zhang, R., & Ma, P. X. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200011)52:2 · Cited by 265
Metadata
- Authors
- Jimbo, Y., Robinson, H. P. C., & Kawana, A.
- Affiliations
- NTT (Japan) (JP)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1993
- Volume
- 40
- Issue
- 8
- Pages
- 804-810
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2051002031
- Cited by
- 192
- References
- 0
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 2 · 2021: 3 · 2020: 2 · 2019: 3 · 2018: 2 · 2017: 1 · 2016: 7 · 2015: 1 · 2014: 5 · 2013: 8 · 2012: 3
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neuropharmacology Research
- Keywords
- intracellular calcium, microelectrode arrays, fluo-3, cortical neurons, neuronal bursting, electrical stimulation, cell positioning, synaptic connectivity, simultaneous recording
- MeSH terms
- Animals, Calcium, Cells, Cultured, Cerebral Cortex, Cytological Techniques, Electric Stimulation, Electrophysiology, Embryo, Mammalian, Equipment Design, Magnesium, Microelectrodes, Nerve Net, Neurons, Semiconductors, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review