A multichannel FES system for the restoration of motor functions in high spinal cord injury patients: a respiration-controlled system for multijoint upper extremity
The DOI matches its Crossref record.
Abstract
A multichannel functional electrical stimulation (FES) system for the restoration of quadriplegic upper extremity function is described. The system is composed of a personal computer NEC PC-8801mkII, peripheral electronic circuits, CRT display and respiratory sensors for volitional control by the patient, and percutaneous electrodes. A C4 quadriplegic patient could drink canned tea by herself by using this FES system. Distinct features of the system are as follows: 1) Versatile volitional control was realized by controlling the memory allocation of the stored stimulation data by voluntary respiratory signals. 2) Sophisticated fine control of the fingers, wrists, and elbow was realized by creating the multichannel stimulation data from recorded myoelectric activities of normal subjects during movements of the upper limb.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Implanted Neuroprosthesis for Restoring Arm and Hand Function in People With High Level Tetraplegia
Memberg, W. D., Polasek, K. H., Hart, R. L., Bryden, A. M., Kilgore, K. L., Nemunaitis, G. A., Hoyen, H. A., Keith, M. W., & Kirsch, R. F. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.01.028 · Cited by 137
Electrical Stimulation and Motor Recovery
Young, W. (2015) · Cell Transplantation · doi:10.3727/096368915x686904 · Cited by 76
Inmann, A., & Haugland, M. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.03.003 · Cited by 40
Some aspects of functional neuromuscular stimulation
Devasahayam, S. R. (1992) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(92)87036-t · Cited by 1
Metadata
- Authors
- Hoshimiya, N., Naito, A., Yajima, M., & Handa, Y.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1989-07
- Volume
- 36
- Issue
- 7
- Pages
- 754-760
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2140196459
- Cited by
- 178
- References
- 0
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A multichannel FES system for the restoration of motor functions in high spinal cord injury patients: a respiration-controlled system for multijoint upper extremity. https://app.cochat.ai/papers/10.1109/10.32108
- The paper
- Hoshimiya, N., Naito, A., Yajima, M., & Handa, Y. (1989). A multichannel FES system for the restoration of motor functions in high spinal cord injury patients: a respiration-controlled system for multijoint upper extremity. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.32108
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.