Cited by 40Neuroscience and Neural EngineeringMuscle activation and electromyography studiesEEG and Brain-Computer Interfaces

Implementation of natural sensory feedback in a portable control system for a hand grasp neuroprosthesis

Inmann, Andreas, Haugland, Morten·2004·Medical Engineering & Physics

Abstract

This paper presents the design and implementation of the first generation of a portable system for a hand grasp neuroprosthesis that is controlled by means of signals from natural sensors in the skin of the index finger. To reduce development time and costs, we based our design on readily available, standardised modules such as a 486DX100 compatible CPU, a data acquisition board, a flash disk storage unit, and a high-efficiency DC/DC switch-mode power supply. Additionally, we designed and built a telemeter to supply an implanted muscle stimulator with power and control data. The signal from the natural sensors was recorded with a cuff electrode implanted around the palmar digital nerve innervating the radial aspect of the index finger. For amplification of the recorded nerve signal, we added an external low-noise nerve signal amplifier. For pre-processing of the recorded nerve signal, an optimised band-pass filter was used. A data-recording unit allowed storage and off-line analysis of the stimulator command and the recorded nerve signal. The portable system was used by a tetraplegic volunteer to test the feasibility of including natural sensors in a hand grasp neuroprosthesis for activities of daily living. The flexibility of the presented system allows rapid prototyping of experimental FES hand grasp systems intended for portable use.

Integrity signals

Registry

Crossref · 10.1016/j.medengphy.2004.03.003

Cites

0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • For hand grasp neural prosthesis, a cuff around the palmar digital nerve recorded mechanoreceptor activity when a grasped object was slipping to regulate grasping force.

    “for hand grasp neural prosthesis, a cuff placed around the palmar digital nerve recorded the activity from mechanoreceptors when a grasped object was slipping to regulate the force of grasping (Haugland and Hoffer, 1994; Haugland et al., 1994; Inmann and Haugland, 2004)”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Inmann, A., & Haugland, M.
Affiliations
Aalborg University (DK)
Corresponding author
Inmann, Andreas
Venue
Medical Engineering & Physics
Published
2004-06-07
Volume
26
Issue
6
Pages
449-458
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W1978006553
Cited by
40
References
0
Citations by year
2020: 1 · 2019: 1 · 2018: 2 · 2017: 1 · 2016: 2 · 2015: 3 · 2013: 5 · 2012: 1
FWCI
1.05
Type
journal article
Language
en
Open access
closed
Locations
  • Medical Engineering & Physics (publishedVersion)
  • PubMed (publishedVersion)
  • VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
Funders
  • European Commission
  • Danmarks Grundforskningsfond
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
Keywords
functional electrical stimulation, skin sensors, index finger, palmar digital nerves, bandpass filtering, tetraplegia, activities of daily living, low-cost prototyping
MeSH terms
Activities of Daily Living, Adult, Electric Stimulation Therapy, Feasibility Studies, Feedback, Feeding Behavior, Hand, Humans, Male, Prosthesis Design, Psychomotor Performance, Quadriplegia, Reflex, Stress, Mechanical, Touch, Treatment Outcome, Hand Strength, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›