Machine learning in control of functional electrical stimulation systems for locomotion
The DOI matches its Crossref record.
Abstract
Two machine learning techniques were evaluated for automatic design of a rule-based control of functional electrical stimulation (FES) for locomotion of spinal cord injured humans. The task was to learn the invariant characteristics of the relationship between sensory information and the FES-control signal by using off-line supervised training. Sensory signals were recorded using pressure sensors installed in the insoles of a subject's shoes and goniometers attached across the joints of the affected leg. The FES-control consisted of pulses corresponding to time intervals when the subject pressed on the manual push-button to deliver the stimulation during FES-assisted ambulation. The machine learning techniques used were the adaptive logic network (ALN) [1] and the inductive learning algorithm (IL) [2]. Results to date suggest that, given the same training data, the IL learned faster than the ALN, while both performed the test rapidly. The generalization was estimated by measuring the test errors and it was better with an ALN, especially if past points were used to reflect the time dimension. Both techniques were able to predict future stimulation events. An advantage of the ALN over the IL was that ALN's can be retrained with new data without losing previously collected knowledge. The advantages of the IL over the ALN were that the IL produces small, explicit, comprehensible trees and that the relative importance of each sensory contribution can be quantified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
A reliable gait phase detection system
Pappas, I. P. I., Popovic, M. R., Keller, T., Dietz, V., & Morari, M. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.928571 · Cited by 495
Au, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
Gait event detection for FES using accelerometers and supervised machine learning
Williamson, R., & Andrews, B. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867873 · Cited by 164
“Kostov [ 14 ] has used Adaptive Logic Networks (ALNs) for stance/swing detection.”
MethodSelf-citationChamroukhi, F., Mohammed, S., Trabelsi, D., Oukhellou, L., & Amirat, Y. (2013) · Neurocomputing · doi:10.1016/j.neucom.2013.04.003 · Cited by 88
“Other sensors are also used to recognize human activities such as video-based systems (Cappozzo et al., 1996, 2005; Aminian et al., 1999), goniometers (Kostov et al., 1995), elec-2 tromyography (EMG) (Hussein and Granat, 2002), etc.”
MethodElectrical Stimulation and Motor Recovery
Young, W. (2015) · Cell Transplantation · doi:10.3727/096368915x686904 · Cited by 76
Fong, J., Ocampo, R., Gross, D. P., & Tavakoli, M. (2020) · Journal of Occupational Rehabilitation · doi:10.1007/s10926-020-09888-w · Cited by 52
“performed a similar project comparing adaptive logic networks and inductive learning algorithms, but instead related foot pressure recordings with Functional Electrical Stimulation activation timing [62].”
Metadata
- Authors
- Kostov, A., Andrews, B. J., Popovic, D. B., Stein, R. B., & Armstrong, W. W.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1995-06
- Volume
- 42
- Issue
- 6
- Pages
- 541-551
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2104540963
- Cited by
- 130
- References
- 0
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.