The application of cepstral coefficients and maximum likelihood method in EMG pattern recognition [movements classification]
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A new technique for classifying patterns of movement via electromyographic (EMG) signals is presented. Two methods (conventional autoregressive (AR) coefficients and cepstral coefficients) for extracting features from EMG signals and three classification algorithms (Euclidean Distance Measure (EDM), Weighted Distance Measure (WDM), and Maximum Likelihood Method (MLM)) for discriminating signals representative of broad classes of movements are described and compared. These three classifiers are derived from Bayes classifier with some assumptions, the relationship among them is discussed. The conventional MLM is modified to avoid heavy matrix inversion. Six able-bodied subjects with two pairs of surface electrodes located on bilateral sternocleidomastoid and upper trapezius muscles were studied in the experiment. The EMG signals of 20 repetitions of 10 motions were analyzed for each subject. Experimental results showed that mean recognition rate of the cepstral coefficients was at least 5% superior to that of the AR coefficients. The improvement achieved by the cepstral method was statistically significant for all the three classifiers. Reasons for the superiority of cepstral features were investigated from the feature space and frequency domain, respectively. The cepstral coefficients owned better cluster separability in feature space and they emphasized the more informative part in the frequency domain. The discrimination rate of the MLM was the highest among three classifiers. Incorporation of the cepstral features with the MLM could reduce the misclassification rate by 10.6% when compared with the combination of AR coefficients and EDM. Proper choice of five of ten motions could further raise the recognition rate to more than 95%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
Cited by
A tutorial on human activity recognition using body-worn inertial sensors
Bulling, A., Blanke, U., & Schiele, B. (2014) · ACM Computing Surveys · doi:10.1145/2499621 · Cited by 1,668
“For physiological or audio signals, these can also be frequency-domain features, such as mel-frequency cepstral coef.cients, or energy in speci.c frequency bands [Kang et al. 1995].”
BackgroundInfluentialScheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Deep Learning for Electromyographic Hand Gesture Signal Classification Using Transfer Learning
Cote-Allard, U., Fall, C. L., Drouin, A., Campeau-Lecours, A., Gosselin, C., Glette, K., Laviolette, F., & Gosselin, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896269 · Cited by 738
Quantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
Resolving the Limb Position Effect in Myoelectric Pattern Recognition
Fougner, A., Scheme, E., Chan, A. D. C., Englehart, K., & Stavdahl, Ø. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163529 · Cited by 402
Metadata
- Authors
- Kang, W.-J., Shiu, J.-R., Cheng, C.-K., Lai, J.-S., Tsao, H.-W., & Kuo, T.-S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1995
- Volume
- 42
- Issue
- 8
- Pages
- 777-785
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2043268735
- Cited by
- 118
- References
- 2
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.