Quantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Open accessAbstract
We evaluated real-time myoelectric pattern recognition control of a virtual arm by transradial amputees. Five unilateral patients performed 10 wrist and hand movements using their amputated and intact arms. In order to demonstrate the value of information from intrinsic hand muscles, this data was included in EMG recordings from the intact arm. With both arms, motions were selected in approximately 0.2 s on average, and completed in less than 1.25 s. Approximately 99% of wrist movements were completed using either arm; however, the completion rate of hand movements was significantly lower for the amputated arm (53.9% +/- 14.2%) than for the intact arm ( 69.4% +/- 13.1%). For the amputated arm, average classification accuracy for only 6 movements-including a single hand grasp-was 93.1% +/- 4.1%, compared to 84.4% +/- 7.2% for all 10 movements. Use of 6 optimally-placed electrodes only reduced this accuracy to 91.5% +/- 4.9%. These results suggest that muscles in the residual forearm produce sufficient myoelectric information for real-time wrist control, but not for performing multiple hand grasps. The outcomes of this study could aid the development of a practical multifunctional myoelectric prosthesis for transradial amputees, and suggest that increased EMG information-such as made available through targeted muscle reinnervation-could improve control of these prostheses.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
That approach gave usable signal amplitude and allowed some prosthetic limb control in transradial amputees.
“This strategy has provided reasonable signal amplitude and some control of a prosthetic limb in patients undergoing transradial amputations (24–28).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [27]
The Introduction says powered transradial prostheses use forearm EMG signal amplitudes for limited control. The Abstract reports that five transradial amputees used residual-forearm signals to control a virtual arm, but the Discussion explicitly says they did not test a physical prosthesis. The paper does not establish a particular ‘reasonable’ signal amplitude. (LLM, conf=0.86)
Experimental — accuracy not yet measuredEarlier studies obtained prosthetic control signals by connecting to intact residual-limb muscles.
“In previous studies, investigators have provided prosthetic control signals by interfacing with intact muscles in the residual limb.”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [27]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · see citing works
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · see citing works
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · see citing works
Self-citationLimb Amputation and Limb Deficiency: Epidemiology and Recent Trends in the United States
Dillingham, T. R., Pezzin, L. E., & MacKenzie, E. J. (2002) · Southern Medical Journal · doi:10.1097/00007611-200208000-00018 · Cited by 822 · see citing works
Myoelectric signal processing for control of powered limb prostheses
Parker, P. K., Englehart, K. B., & Hudgins, B. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.006 · Cited by 648 · see citing works
Classification of the myoelectric signal using time-frequency based representations
Englehart, K. B., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 641 · see citing works
Huang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 641 · see citing works
A Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K. B., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 519 · see citing works
A Strategy for Identifying Locomotion Modes Using Surface Electromyography
Huang, H., Kuiken, T., & Lipschutz, R. D. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2003293 · Cited by 517 · see citing works
Self-citationThe optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438 · see citing works
Fuzzy EMG classification for prosthesis control.
Chan, F. H. Y., Yang, Y.-S., Lam, F., Zhang, Y.-T., & Parker, P. A. (2000) · IEEE transactions on rehabilitation engineering · doi:10.1109/86.867872 · Cited by 419 · see citing works
A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415 · see citing works
Chu, J., Moon, I., & Mun, M.-S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883695 · Cited by 351 · see citing works
Continuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models
Chan, A. D. C., & Englehart, K. B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836492 · Cited by 344 · see citing works
EMG Pattern Analysis and Classification for a Prosthetic Arm
Saridis, G. N., & Gootee, T. P. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324954 · Cited by 238 · see citing works
Decoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215 · see citing works
Self-citationEMG pattern recognition based on artificial intelligence techniques
Park, S., & Lee, S.-P. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736154 · Cited by 199 · see citing works
Myoelectric control of prostheses.
Parker, P. A., & Scott, R. N. (1986) · PubMed · Cited by 199 · see citing works
Huang, H., Zhou, P., Li, G., & Kuiken, T. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.910282 · Cited by 186 · see citing works
Self-citationTowards the Control of Individual Fingers of a Prosthetic Hand Using Surface EMG Signals
Tenore, F. V., Ramos‐Murguialday, A., Fahmy, A., Acharya, S., Etienne‐Cummings, R., & Thakor, N. V. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353752 · Cited by 154 · see citing works
Momen, K. S., Krishnan, S., & Chau, T. T. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.908376 · Cited by 152 · see citing works
Sebelius, F., Rosén, B., & Lundborg, G. (2005) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2005.01.002 · Cited by 119 · see citing works
Kang, W.-J., Shiu, J.-R., Cheng, C., Lai, J., Tsao, H., & Kuo, T. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.398638 · Cited by 118 · see citing works
REAL-TIME MYOELECTRIC CONTROL IN A VIRTUAL ENVIRONMENT TO RELATE USABILITY VS. ACCURACY
Lock, B. A., Englehart, K. B., & Hudgins, B. (2005) · DukeSpace (Duke University) · Cited by 102 · see citing works
Micera, S., Sabatini, A. M., Dario, P., & Rossi, B. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00055-7 · Cited by 90 · see citing works
Gibson, D. (1982) · Europe PMC (PubMed Central) · Cited by 87 · see citing works
Feature-based classification of myoelectric signals using artificial neural networks
Gallant, P. J., Morin, E. L., & Peppard, L. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523219 · Cited by 51 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Atzori, M., Cognolato, M., & Müller, H. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00009 · Cited by 684 · see citing works
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291 · see citing works
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252 · see citing works
Online Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees
Cipriani, C., Antfolk, C., Controzzi, M., Lundborg, G., Rosen, B., Carrozza, M. C., & Sebelius, F. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2108667 · Cited by 233 · see citing works
Targeted Muscle Reinnervation and Advanced Prosthetic Arms
Cheesborough, J., Smith, L., Kuiken, T., & Dumanian, G. (2015) · Seminars in Plastic Surgery · doi:10.1055/s-0035-1544166 · Cited by 206 · see citing works
Self-citationSchultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186 · see citing works
Self-citationBio-signal based elbow angle and torque simultaneous prediction during isokinetic contraction
Zhou, Y., Liu, J., Zeng, J., Li, K., & Liu, H. (2019) · Science China Technological Sciences · doi:10.1007/s11431-018-9354-5 · Cited by 30 · see citing works
- Authors
- Li, G., Schultz, A. E., & Kuiken, T. A.
- Affiliations
- Shirley Ryan AbilityLab (US)
- Northwestern University (US)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2010-04
- Volume
- 18
- Issue
- 2
- Pages
- 185-192
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- PMC
- PMC3024915
- OpenAlex
- W2096553993
- Cited by
- 443
- References
- 27
- Citations by year
- 2026: 5 · 2025: 16 · 2024: 17 · 2023: 30 · 2022: 25 · 2021: 23 · 2020: 27 · 2019: 27 · 2018: 34 · 2017: 38 · 2016: 31 · 2015: 26 · 2014: 43 · 2013: 40 · 2012: 22
- FWCI
- 19.07
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Northwestern University
- National Institutes of Health (5r01hd058000-05, 5r01hd043137-05)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01-HD-05-8000, R01 HD-043137)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- myoelectric control, transradial amputation, pattern recognition, EMG signal classification, virtual arm, wrist kinematics, hand grasp, electrode placement, targeted muscle reinnervation
- MeSH terms
- Adult, Aged, Algorithms, Amputation, Surgical, Arm, Artificial Limbs, Electrodes, Implanted, Forearm, Hand, Humans, Learning, Middle Aged, Motion, Pattern Recognition, Automated, Pilot Projects, Prosthesis Design, Radius, Wrist, Muscle, Skeletal, Hand Strength
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review