The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Genetic design of optimum linear and nonlinear QRS detectors
Abstract
This paper describes an approach to the design of optimum QRS detectors. We report on detectors including a linear or nonlinear polynomial filter, which enhances and rectifies the QRS complex, and a simple, adaptive maxima detector. The parameters of the filter and the detector, and the samples to be processed are selected by a genetic algorithm which minimizes the detection errors made on a set of reference ECG signals. Three different architectures and the experimental results achieved on the MIT-BIH Arrhythmia Database are described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043 · cited 3×
“[ 3 ] J. P. C. de Wmd, “A posteriori time-varying filtering of averaged evoked potentials: I. Introduction and conceptual basis,” Biol.”
BackgroundMethodInfluential
Cited by
A Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martinez, J. P., Almeida, R., Olmos, S., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,605
The principles of software QRS detection
Kohler, B.-U., Hennig, C., & Orglmeister, R. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.993193 · Cited by 1,242
Search-based software engineering
Harman, M., & Jones, B. F. (2001) · Information and Software Technology · doi:10.1016/s0950-5849(01)00189-6 · Cited by 914
ECG-based heartbeat classification for arrhythmia detection: A survey
Luz, E. J. D. S., Schwartz, W. R., Cámara-Chávez, G., & Menotti, D. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.12.008 · Cited by 878
Real time electrocardiogram QRS detection using combined adaptive threshold
Christov, I. I. (2004) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-3-28 · Cited by 464
Metadata
- Authors
- Poli, R., Cagnoni, S., & Valli, G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1995
- Volume
- 42
- Issue
- 11
- Pages
- 1137-1141
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2113804337
- Cited by
- 238
- References
- 2
- FWCI
- 0.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.