Cited by 1,043ECG Monitoring and AnalysisNon-Invasive Vital Sign MonitoringHeart Rate Variability and Autonomic Control

A comparison of the noise sensitivity of nine QRS detection algorithms

Friesen, G.M., Jannett, T.C., Jadallah, M.A., Yates, S.L., Quint, S.R., Nagle, H.T.·1990·IEEE Transactions on Biomedical Engineering

Abstract

The noise sensitivities for nine different QRS detection algorithms were measured for a normal, single-channel lead II, synthesized ECG corrupted with five different types of synthesized noise. The noise types were electromyographic interference, 60 Hz powerline interference, baseline drift due to respiration, abrupt baseline shift, and a composite noise constructed from all of the other noise types. The percentage of QRS complexes detected, the number of false positives, and the detection delay were measured. None of the algorithms were able to detect all QRS complexes without any false positives for all of the noise types at the highest noise level. Algorithms based on amplitude and slope had the highest performance for EMG-corrupted ECG. An algorithm using a digital filter had the best performance for the composite noise corrupted data.

Integrity signals

Registry

Crossref · 10.1109/10.43620

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T.
Affiliations
  • Auburn University (US)
  • University of Alabama (US)
  • North Carolina State University (US)
  • North Carolina Agricultural and Technical State University (US)
Venue
IEEE Transactions on Biomedical Engineering
Published
1990
Volume
37
Issue
1
Pages
85-98
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2104563593
Cited by
1,043
References
0
Citations by year
2026: 7 · 2025: 21 · 2024: 20 · 2023: 22 · 2022: 34 · 2021: 30 · 2020: 41 · 2019: 47 · 2018: 45 · 2017: 47 · 2016: 53 · 2015: 43 · 2014: 56 · 2013: 47 · 2012: 48
FWCI
3.39
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
QRS complex detection, noise sensitivity, ECG, electromyographic interference, baseline drift, respiration, baseline shift, false positives, detection delay, digital filters, algorithm comparison
MeSH terms
Algorithms, Computer Simulation, Electrocardiography, Models, Cardiovascular, Signal Processing, Computer-Assisted, Software

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review