The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Morphological model of human colon tissue fluorescence
Abstract
Fluorescence spectroscopy of tissue is a promising technique for early detection of precancerous changes in the human body. Investigation of the microscopic origin of the clinically observed tissue fluorescence can provide valuable information about the tissue's histology. The objective of this study was the development of a morphological model of colon tissue fluorescence which connects the clinically observed spectra with their underlying microscopic origins. Clinical colon tissue fluorescence which connects the clinically observed spectra with their underlying microscopic origins. Clinical colon tissue fluorescence spectra were modeled by measuring the intrinsic fluorescence properties of colon tissue on a microscopic level and by simulating light propagation in tissue using the Monte-Carlo method. The computed spectra were in good agreement with the clinical spectra acquired during colonoscopy, and exhibited the characteristic spectral features of the in vivo collected spectra. Our analysis quantitated these spectral features in terms of the intrinsic fluorescence properties of tissue and its general histological characteristics. The fluorescence intensity difference between normal and adenoma observed in vivo was found to be due to the increased hemoglobin absorption, the reduced mucosal fluorescence intensity, and the absence of submucosal fluorescence in adenomatous polyps. The increased red fluorescence in adenoma was found to be associated with the dysplastic crypt cell fluorescence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Cited by
In Vivo Fluorescence Spectroscopy and Imaging for Oncological Applications
Wagnieres, G. A., Star, W. M., & Wilson, B. C. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb02521.x · Cited by 942
Fluorescence Spectroscopy of Neoplastic and Non-Neoplastic Tissues
Ramanujam, N. (2000) · Neoplasia · doi:10.1038/sj.neo.7900077 · Cited by 654
Autofluorescence spectroscopy and imaging: a tool for biomedical research and diagnosis
Croce, A. C., & Bottiroli, G. (2014) · European Journal of Histochemistry · doi:10.4081/ejh.2014.2461 · Cited by 628
Diffuse reflectance spectroscopy of human adenomatous colon polyps in vivo
Zonios, G., Perelman, L. T., Backman, V., Manoharan, R., Fitzmaurice, M., Van Dam, J., & Feld, M. S. (1999) · Applied Optics · doi:10.1364/ao.38.006628 · Cited by 534
Self-citationFluorescence Spectroscopy In Vivo
Ramanujam, N. (2000) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a0102 · Cited by 508
Metadata
- Authors
- Zonios, G. I., Cothren, R. M., Arendt, J. T., Wu, J., Van Dam, J., Crawford, J. M., Manoharan, R., & Feld, M. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1996
- Volume
- 43
- Issue
- 2
- Pages
- 113-122
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2139735777
- Cited by
- 165
- References
- 1
- FWCI
- 10.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Morphological model of human colon tissue fluorescence. https://app.cochat.ai/papers/10.1109/10.481980
- The paper
- Zonios, G. I., Cothren, R. M., Arendt, J. T., Wu, J., Van Dam, J., Crawford, J. M., Manoharan, R., & Feld, M. S. (1996). Morphological model of human colon tissue fluorescence. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.481980
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.