The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
The application of neural networks to myoelectric signal analysis: a preliminary study
Abstract
Two neural network implementations are applied to myoelectric signal (MES) analysis tasks. The motivation behind this research is to explore more reliable methods of deriving control for multidegree of freedom arm prostheses. A discrete Hopfield network is used to calculate the time series parameters for a moving average MES model. It is demonstrated that the Hopfield network is capable of generating the same time series parameters as those produced by the conventional sequential least squares (SLS) algorithm. Furthermore, it can be extended to applications utilizing larger amounts of data, and possibly to higher order time series models, without significant degradation in computational efficiency. The second neural network implementation involves using a two-layer perceptron for classifying a single site MES based on two features, specifically the first time series parameter, and the signal power. Using these features, the perceptron is trained to distinguish between four separate arm functions. The two-dimensional decision boundaries used by the perceptron classifier are delineated. It is also demonstrated that the perceptron is able to rapidly compensate for variations when new data are incorporated into the training set. This adaptive quality suggests that perceptrons may provide a useful tool for future MES analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hopfield, J. J. (1984) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.81.10.3088 · Cited by 6,918
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
Graupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205
Research works printed but not linked: 17
- 10.1086/164700 · DOI
- haykin, 1986, Adaptive Filter Theory
- peeling, 1986, The multilayer perceptron as a tool for speech pattern processing research, Proc I O A Autumn Conf Speech and Hearing, 8, 307
- 10.1016/0893-6080(88)90023-8 · DOI · Paper page
- sejnowski, 1986, NETtalk A parallel network that learns to read aloud
- rumelhart, 1986, Parallel Distributed Processing Explorations in the Microstructure of Cognition, 10.7551/mitpress/5236.001.0001 · DOI · Paper page
- almstrom, 1977, An Electric System for a Prosthetic Hand with Six Degrees of Freedom
- 10.1109/TBME.1982.324954 · DOI · Paper page
- 10.1109/TBME.1983.325162 · DOI · Paper page
- 10.1109/TCS.1986.1085953 · DOI · Paper page
- 10.1109/MASSP.1987.1165576 · DOI · Paper page
- gander, 1985, Power spectral density of the surface myoelectric signal of the biceps brachii as a function of static load, Electromyogr Clin Neurophysiol, 25, 469
- graupe, 1984, Time series analysis identification and adaptive filtering
- basmajian, 1985, Muscles Alive Their Functions Revealed by Electromyography
- 10.1016/0141-5425(85)90004-4 · DOI
- hopfield, 1985, Biol Cybern, 52, 141, 10.1007/BF00339943 · DOI · Paper page
- 10.3109/17453677308989075 · DOI
Cited by
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
Self-citationA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Metadata
- Authors
- Kelly, M. F., Parker, P. A., & Scott, R. N.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1990-03
- Volume
- 37
- Issue
- 3
- Pages
- 221-230
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2019773173
- Cited by
- 221
- References
- 3
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The application of neural networks to myoelectric signal analysis: a preliminary study. https://app.cochat.ai/papers/10.1109/10.52324
- The paper
- Kelly, M. F., Parker, P. A., & Scott, R. N. (1990). The application of neural networks to myoelectric signal analysis: a preliminary study. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.52324
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.