The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
ECG data compression techniques-a unified approach
Abstract
A broad spectrum of techniques for electrocardiogram (ECG) data compression have been proposed during the last three decades. Such techniques have been vital in reducing the digital ECG data volume for storage and transmission. These techniques are essential to a wide variety of applications ranging from diagnostic to ambulatory ECG's. Due to the diverse procedures that have been employed, comparison of ECG compression methods is a major problem. Present evaluation methods preclude any direct comparison among existing ECG compression techniques. The main purpose of this paper is to address this issue and to establish a unified view of ECG compression techniques. ECG data compression schemes are presented in two major groups: direct data compression and transformation methods. The direct data compression techniques are: ECG differential pulse code modulation and entropy coding, AZTEC, Turning-point, CORTES, Fan and SAPA algorithms, peak-picking, and cycle-to-cycle compression methods. The transformation methods briefly presented, include: Fourier, Walsh, and K-L transforms. The theoretical basis behind the direct ECG data compression schemes are presented and classified into three categories: tolerance-comparison compression, differential pulse code modulation (DPCM), and entropy coding methods. The paper concludes with the presentation of a framework for evaluation and comparison of ECG compression schemes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01338.x · Cited by 88,486
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb00917.x · Cited by 48,949
A Method for the Construction of Minimum-Redundancy Codes
Huffman, D. (1952) · Proceedings of the IRE · doi:10.1109/jrproc.1952.273898 · Cited by 6,334
Linear prediction: A tutorial review
Makhoul, J. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.9792 · Cited by 4,023
Arithmetic coding for data compression
Witten, I. H., Neal, R. M., & Cleary, J. G. (1987) · Communications of the ACM · doi:10.1145/214762.214771 · Cited by 2,877
Digital Processing of Speech Signals
Ackroyd, M. H. (1979) · Electronics and Power · doi:10.1049/ep.1979.0173 · Cited by 2,391
Digital coding of waveforms. Principles and applications to speech and video
Jayant, N. S., & Noll, P. (1985) · Signal Processing · doi:10.1016/0165-1684(85)90053-2 · Cited by 1,111
Orthogonal Transforms for Digital Signal Processing
Ahmed, N., & Rao, K. R. (1975) · Springer eBooks · doi:10.1007/978-3-642-45450-9 · Cited by 948
Orthogonal transforms for digital signal processing
Rao, K., & Ahmed, N. (2005) · ICASSP '76. IEEE International Conference on Acoustics, Speech, and Signal Processing · doi:10.1109/icassp.1976.1170121 · Cited by 830
Image data compression: A review
Jain, A. K. (1981) · Proceedings of the IEEE · doi:10.1109/proc.1981.11971 · Cited by 709
Holter, N. J. (1961) · Science · doi:10.1126/science.134.3486.1214 · Cited by 568
A digital signal processing approach to interpolation
Schafer, R. W., & Rabiner, L. R. (1973) · Proceedings of the IEEE · doi:10.1109/proc.1973.9150 · Cited by 554
Netravali, A. N., & Limb, J. O. (1980) · Proceedings of the IEEE · doi:10.1109/proc.1980.11647 · Cited by 451
Lelewer, D. A., & Hirschberg, D. S. (1987) · ACM Computing Surveys · doi:10.1145/45072.45074 · Cited by 377
AZTEC, a Preprocessing Program for Real-Time ECG Rhythm Analysis
Cox, J. R., Nolle, F. M., Fozzard, H. A., & Oliver, G. C. (1968) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1968.4502549 · Cited by 367
KOSSMANN, C. E., BRODY, D. A., BURCH, G. E., HECHT, H. H., JOHNSTON, F. D., KAY, C., LEPESCHKIN, E., PIPBERGER, H. V., PIPBERGER, H. V., BAULE, G., et al. (1967) · Circulation · doi:10.1161/01.cir.35.3.583 · Cited by 307
A New Data-Reduction Algorithm for Real-Time ECG Analysis
Abenstein, J. P., & Tompkins, W. J. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324962 · Cited by 269
Digital coding of speech waveforms: PCM, DPCM, and DM quantizers
Jayant, N. S. (1974) · Proceedings of the IEEE · doi:10.1109/proc.1974.9484 · Cited by 257
Software QRS detection in ambulatory monitoring — a review
Pahlm, O., & Sörnmo, L. (1984) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442095 · Cited by 253
Adaptive Quantization in Differential PCM Coding of Speech
Cummiskey, P., Jayant, N. S., & Flanagan, J. L. (1973) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1973.tb02007.x · Cited by 203
ECG Data Compression Using Fourier Descriptors
Reddy, B. R. S., & Murthy, I. S. N. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325799 · Cited by 172
Electrocardiographic Data Compression Via Orthogonal Transforms
Ahmed, N., Milne, P. J., & Harris, S. G. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324469 · Cited by 144
Scan-Along Polygonal Approximation for Data Compression of Electrocardiograms
Ishijima, M., Shin, S.-B., Hostetter, G. H., & Sklansky, J. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325186 · Cited by 137
Digital analysis of the electroencephalogram, the blood pressure wave, and the electrocardiogram
Cox, J. R., Nolle, F. M., & Arthur, R. M. (1972) · Proceedings of the IEEE · doi:10.1109/proc.1972.8877 · Cited by 128
McDonald, R. A. (1966) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1966.tb01690.x · Cited by 117
Factor Analysis of the Electrocardiogram
Scher, A. M., Young, A. C., & Meredith, W. M. (1960) · Circulation Research · doi:10.1161/01.res.8.3.519 · Cited by 97
Eliaš, P. (1955) · IEEE Transactions on Information Theory · doi:10.1109/tit.1955.1055116 · Cited by 95
Oliver, B. M. (1952) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1952.tb01403.x · Cited by 71
Algorithms for adaptive Huffman codes
Cormack, G. V., & Horspool, R. N. (1984) · Information Processing Letters · doi:10.1016/0020-0190(84)90021-8 · Cited by 60
Sparse Spatial Coding: A novel approach for efficient and accurate object recognition
Oliveira, G. L., Nascimento, E. R., Vieira, A. W., & Campos, M. F. M. (2012) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2012.6224785 · Cited by 59
Artefactual ST segment abnormalities due to electrocardiograph design.
Tayler, D. I., & Vincent, R. (1985) · Heart · doi:10.1136/hrt.54.2.121 · Cited by 57
Signal Distortion in the Electrocardiogram Due to Inadequate Phase Response
Tayler, D. I., & Vincent, R. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325137 · Cited by 56
Bibliography on data compression, picture properties, and picture coding
Wilkins, L. C., & Wintz, P. A. (1971) · IEEE Transactions on Information Theory · doi:10.1109/tit.1971.1054594 · Cited by 33
The theoretical analysis of data compression systems
Davisson, L. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6212 · Cited by 33
Comparison of methods for adaptive sampling of cardiac electrograms and electrocardiograms
Blanchard, S. M., & Barr, R. C. (1985) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441592 · Cited by 32
Entropy coding in speech and television differential PCM systems (Corresp.)
O'Neal, J. B. (1971) · IEEE Transactions on Information Theory · doi:10.1109/tit.1971.1054706 · Cited by 30
Longini, R. L., Giolma, J. P., Wall, C., & Quick, R. F. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324517 · Cited by 30
A plea for common standards in computer aided ECG analysis
Willems, J. L. (1980) · Computers and Biomedical Research · doi:10.1016/0010-4809(80)90011-7 · Cited by 28
Adaptive sampling of intracellular and extracellular cardiac potentials with the fan method
Pollard, A. E., & Barr, R. C. (1987) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447422 · Cited by 19
Precision Requirements for Electrocardiographic Measurements Computed Automatically
Berson, A. S., Wojick, J. M., & Pipberger, H. V. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326146 · Cited by 13
Do we need a new standard for electrocardiographs?
Gold, R. (1985) · Heart · doi:10.1136/hrt.54.2.119 · Cited by 9
Data compression techniques for electrocardiograms
Shridhar, M., & Mohankrishnan, N. (1984) · Canadian Electrical Engineering Journal · doi:10.1109/ceej.1984.6590967 · Cited by 8
Cited by
Wavelet transforms and the ECG: a review
Addison, P. S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/r01 · Cited by 908
Recommendations for the Standardization and Interpretation of the Electrocardiogram
Kligfield, P., Gettes, L. S., Bailey, J. J., Childers, R., Deal, B. J., Hancock, E. W., van Herpen, G., Kors, J. A., Macfarlane, P., Mirvis, D. M., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.024 · Cited by 807
Kligfield (2007) · doi:10.1161/circulationaha.106.180200 · Cited by 802
Compressed Sensing for Real-Time Energy-Efficient ECG Compression on Wireless Body Sensor Nodes
Mamaghanian, H., Khaled, N., Atienza, D., & Vandergheynst, P. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2156795 · Cited by 701
Wavelet compression of ECG signals by the set partitioning in hierarchical trees algorithm
Lu, Z., Kim, D. Y., & Pearlman, W. A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846678 · Cited by 497
Metadata
- Authors
- Jalaleddine, S. M. S., Hutchens, C. G., Strattan, R. D., & Coberly, W. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1990-04
- Volume
- 37
- Issue
- 4
- Pages
- 329-343
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2155321485
- Cited by
- 681
- References
- 42
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.