The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Estimating alertness from the EEG power spectrum
Abstract
In tasks requiring sustained attention, human alertness varies on a minute time scale. This can have serious consequences in occupations ranging from air traffic control to monitoring of nuclear power plants. Changes in the electroencephalographic (EEG) power spectrum accompany these fluctuations in the level of alertness, as assessed by measuring simultaneous changes in EEG and performance on an auditory monitoring task. By combining power spectrum estimation, principal component analysis and artificial neural networks, we show that continuous, accurate, noninvasive, and near real-time estimation of an operator's global level of alertness is feasible using EEG measures recorded from as few as two central scalp sites. This demonstration could lead to a practical system for noninvasive monitoring of the cognitive state of human operators in attention-critical settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Learning Internal Representations by Error Propagation
Rumelhart, D. E., Hinton, G. E., & Williams, R. J. (1985) · doi:10.21236/ada164453 · Cited by 16,172
Numerical Taxonomy: The Principles and Practice of Numerical Classification
Corliss, J. O., Sneath, P. H. A., & Sokal, R. R. (1974) · Transactions of the American Microscopical Society · doi:10.2307/3225339 · Cited by 3,407
The Breakdown of Vigilance during Prolonged Visual Search
Mackworth, N. H. (1948) · Quarterly Journal of Experimental Psychology · doi:10.1080/17470214808416738 · Cited by 1,035
Lapse in alertness: coherence of fluctuations in performance and EEG spectrum
Makeig, S., & Inlow, M. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90064-3 · Cited by 338
Self-citationThe EEG of Drowsiness in Normal Adults
Santamaria, J., & Chiappa, K. H. (1987) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-198710000-00002 · Cited by 331
The Event-Related Brain Potential as an Index of Display-Monitoring Workload
Isreal, J. B., Wickens, C. D., Chesney, G. L., & Donchin, E. (1980) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/001872088002200210 · Cited by 309
THE FINE STRUCTURE OF PSYCHOLOGICAL TIME
Stroud, J. M. (1967) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1967.tb55012.x · Cited by 301
Changes in alertness are a principal component of variance in the EEG spectrum
Makeig, S., & Jung, T.-P. (1995) · NeuroReport · doi:10.1097/00001756-199512000-00051 · Cited by 229
Self-citationGeneralization and Parameter Estimation in Feedforward Nets: Some Experiments
Morgan, N., & Bourlard, H. (1989) · neural information processing systems · Cited by 225
HUMAN BRAIN POTENTIALS DURING THE ONSET OF SLEEP
Davis, H., Davis, P. A., Loomis, A. L., Harvey, E. N., & Hobart, G. (1938) · Journal of Neurophysiology · doi:10.1152/jn.1938.1.1.24 · Cited by 214
Operant Control of Occipital Theta Rhythm Affects Performance in a Radar Monitoring Task
Beatty, J., Greenberg, A., Deibler, W. P., & O’Hanlon, J. F. (1974) · Science · doi:10.1126/science.183.4127.871 · Cited by 157
Changes in electrical activity of the brain with vigilance
Belyavin, A., & Wright, N. A. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90183-0 · Cited by 155
Changes in Human Brain Potentials During the Onset of Sleep
Davis, H., Davis, P. A., Loomis, A. L., Harvey, E. N., & Hobart, G. (1937) · Science · doi:10.1126/science.86.2237.448 · Cited by 154
Minimum-bias windows for high-resolution spectral estimates
Papoulis, A. (1973) · IEEE Transactions on Information Theory · doi:10.1109/tit.1973.1054956 · Cited by 140
Human vigilance and auditory evoked responses
Fruhstorfer, H., & Bergström, R. M. (1969) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(69)91443-6 · Cited by 139
A method for assessing alertness fluctuations from EEG spectra
Matouŝek, M., & Petersén, I. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90154-2 · Cited by 138
Temporal Rhythms and Cerebral Rhythmsa
Treisman, M. (1984) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1984.tb23458.x · Cited by 116
Steriade, M. (1993) · Current Opinion in Neurobiology · doi:10.1016/0959-4388(93)90064-6 · Cited by 93
Cited by
Berridge, C. W., & Waterhouse, B. D. (2003) · Brain Research Reviews · doi:10.1016/s0165-0173(03)00143-7 · Cited by 2,529
Borghini, G., Astolfi, L., Vecchiato, G., Mattia, D., & Babiloni, F. (2014) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2012.10.003 · Cited by 1,331
Sleep Deprivation and Vigilant Attention
Lim, J., & Dinges, D. F. (2008) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1417.002 · Cited by 1,213
Vigilance, alertness, or sustained attention: physiological basis and measurement
Oken, B. S., Salinsky, M. C., & Elsas, S. M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.01.017 · Cited by 887
Alpha rhythm of the EEG modulates visual detection performance in humans
Ergenoglu, T., Demiralp, T., Bayraktaroglu, Z., Ergen, M., Beydagi, H., & Uresin, Y. (2004) · Cognitive Brain Research · doi:10.1016/j.cogbrainres.2004.03.009 · Cited by 575
Metadata
- Authors
- Jung, T.-P., Makeig, S., Stensmo, M., & Sejnowski, T. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1997
- Volume
- 44
- Issue
- 1
- Pages
- 60-69
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2056108528
- Cited by
- 480
- References
- 18
- FWCI
- 2.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.