An improved method for localizing electric brain dipoles
The DOI matches its Crossref record.
Abstract
Methods for localizing electrical dipolar sources in the brain differ from one another by the models they use to represent the head, the specific formulas used in the calculation of the scalp potentials, the way that the reference electrode is treated, and by the algorithm employed to find the least-squares fit between the measured and calculated EEG potentials. The model presented here is based on some of the most advanced features found in other models, and on some improvements. The head is represented by a three-layer spherical model. The potential on any point on the scalp due to any source is found by a closed formula, which is not based on matrix rotations. The formulas will accept any surface electrode as the reference electrode. The least-squares procedure is based on optimal dipoles, reducing the number of unknowns in the iterations from six to three. The new method was evaluated by localizing five implanted dipolar sources in human sensorimotor cortex. The distances between the locations of the sources as calculated by the method, and the actual locations were between 0.4 and 2.0 cm. The sensitivity of the method to uncertainties encountered whenever a real head has to be modeled by a three-layer model has also been assessed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561
“The surface potential of the outer layer was calculated with the algorithm described in [6].”
MethodReview on solving the inverse problem in EEG source analysis
Grech, R., Cassar, T., Muscat, J., Camilleri, K. P., Fabri, S. G., Zervakis, M., Xanthopoulos, P., Sakkalis, V., & Vanrumste, B. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-25 · Cited by 1,193
Review on solving the forward problem in EEG source analysis
Hallez, H., Vanrumste, B., Grech, R., Muscat, J., De Clercq, W., Vergult, A., D'Asseler, Y., Camilleri, K. P., Fabri, S. G., Van Huffel, S., et al. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-46 · Cited by 527
An alternative subspace approach to EEG dipole source localization
Xu, X.-L., Xu, B., & He, B. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/2/010 · Cited by 73
Metadata
- Authors
- Salu, Y., Cohen, L. G., Rose, D., Sxato, S., Kufta, C., & Hallett, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1990-07
- Volume
- 37
- Issue
- 7
- Pages
- 699-705
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2129618485
- Cited by
- 103
- References
- 0
- FWCI
- 0.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An improved method for localizing electric brain dipoles. https://app.cochat.ai/papers/10.1109/10.55680
- The paper
- Salu, Y., Cohen, L. G., Rose, D., Sxato, S., Kufta, C., & Hallett, M. (1990). An improved method for localizing electric brain dipoles. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.55680
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.