The DOI matches its Crossref record; 100 of the 100 references it cites were found in a registry or an index.
Review on solving the inverse problem in EEG source analysis
Open accessAbstract
In this primer, we give a review of the inverse problem for EEG source localization. This is intended for the researchers new in the field to get insight in the state-of-the-art techniques used to find approximate solutions of the brain sources giving rise to a scalp potential recording. Furthermore, a review of the performance results of the different techniques is provided to compare these different inverse solutions. The authors also include the results of a Monte-Carlo analysis which they performed to compare four non parametric algorithms and hence contribute to what is presently recorded in the literature. An extensive list of references to the work of other researchers is also provided. This paper starts off with a mathematical description of the inverse problem and proceeds to discuss the two main categories of methods which were developed to solve the EEG inverse problem, mainly the non parametric and parametric methods. The main difference between the two is to whether a fixed number of dipoles is assumed a priori or not. Various techniques falling within these categories are described including minimum norm estimates and their generalizations, LORETA, sLORETA, VARETA, S-MAP, ST-MAP, Backus-Gilbert, LAURA, Shrinking LORETA FOCUSS (SLF), SSLOFO and ALF for non parametric methods and beamforming techniques, BESA, subspace techniques such as MUSIC and methods derived from it, FINES, simulated annealing and computational intelligence algorithms for parametric methods. From a review of the performance of these techniques as documented in the literature, one could conclude that in most cases the LORETA solution gives satisfactory results. In situations involving clusters of dipoles, higher resolution algorithms such as MUSIC or FINES are however preferred. Imposing reliable biophysical and psychological constraints, as done by LAURA has given superior results. The Monte-Carlo analysis performed, comparing WMN, LORETA, sLORETA and SLF, for different noise levels and different simulated source depths has shown that for single source localization, regularized sLORETA gives the best solution in terms of both localization error and ghost sources. Furthermore the computationally intensive solution given by SLF was not found to give any additional benefits under such simulated conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“This is due to the inverse problem of being unable to predict the pattern of neural firing responsible for generating a particular EEG signal, solely from the EEG signal (Grech et al., 2008; Baillet, 2014).”
From Consciousness: Matter or EMF? (2023) · cites this paper as Grech et al., 2008
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Standardized low-resolution brain electromagnetic tomography (sLORETA): technical details.
Pascual-Marqui, R. D. (2002) · PubMed · Cited by 4,070
Rank-Deficient and Discrete Ill-Posed Problems: Numerical Aspects of Linear Inversion
Hansen, P. C. (1998) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898719697 · Cited by 2,909
Introductory functional analysis with applications
Kreyszig, E. (1978) · Cited by 2,889
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561
Computational Methods for Inverse Problems
Vogel, C. R. (2002) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898717570 · Cited by 2,370
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
Sparse signal reconstruction from limited data using FOCUSS: a re-weighted minimum norm algorithm
Gorodnitsky, I. F., & Rao, B. D. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.558475 · Cited by 1,834
Rue, H., & Held, L. (2005) · Chapman & Hall/CRC eBooks · doi:10.1201/9780203492024 · Cited by 1,823
Dynamic Statistical Parametric Mapping
Dale, A. M., Liu, A. K., Fischl, B. R., Buckner, R. L., Belliveau, J. W., Lewine, J. D., & Halgren, E. (2000) · Neuron · doi:10.1016/s0896-6273(00)81138-1 · Cited by 1,787
Research works printed but not linked: 6
- Hansen PC: Rank-Deficient and Discrete Ill-Posed Problems. SIAM 1998.
- Baillet S: Toward Functional Brain Imaging of Cortical Electrophysiology Markovian Models for Magneto and Electroencephalogram Source Estimation and Experimental Assessments. In Ph.D thesis. University of Paris-ParisXI, Orsay, France; 1998.
- Riera JJ, Valdes PA, Fuentes ME, Oharriz Y: Explicit Backus and Gilbert EEG Inverse Solution for Spherical Symmetry. Department of Neurophysics, Cuban Neuroscience Center, Havana, Cuba 2002, in press.
- Tun AK, Lye NT, Guanglan Z, Abeyratne UR, Saratchandran P: RBF networks for source localization in quantitative electrophysiology. EMBS 1998, 2190-2192. [Oct 29 Nov 1, Hong Kong]
- Kinouchi Y, Oki H, Okada J, Shichijo F, Matsumoto K: Artificial neural networks for source localization in the human brain. Brain Topography 1991,4(1):3-21. 10.1007/BF01129661 · DOI
- Weinstein DM, Zhukov L, Potts G: Localization of Multiple Deep Epileptic Sources in a Realistic Head Model via Independent Component Analysis. Tech. rep., School of Computing, University of Utah; 2000.
Cited by
The steady-state visual evoked potential in vision research: A review
Norcia, A. M., Appelbaum, L. G., Ales, J. M., Cottereau, B. R., & Rossion, B. (2015) · Journal of Vision · doi:10.1167/15.6.4 · Cited by 1,234
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Review of advanced techniques for the estimation of brain connectivity measured with EEG/MEG
Sakkalis, V. (2011) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2011.06.020 · Cited by 637
Self-citationEEG source localization: Sensor density and head surface coverage
Song, J., Davey, C., Poulsen, C., Luu, P., Turovets, S., Anderson, E., Li, K., & Tucker, D. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.08.015 · Cited by 356
Revil, A., Karaoulis, M., Johnson, T., & Kemna, A. (2012) · Hydrogeology Journal · doi:10.1007/s10040-011-0819-x · Cited by 339
Metadata
- Authors
- Grech, R., Cassar, T., Muscat, J., Camilleri, K. P., Fabri, S. G., Zervakis, M., Xanthopoulos, P., Sakkalis, V., & Vanrumste, B.
- Affiliations
- University of Malta (MT)
- Technical University of Crete (GR)
- KU Leuven (BE)
- ORCID
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2008-11-07
- Volume
- 5
- Issue
- 1
- Pages
- 25-25
- ISSN
- 1743-0003 (ISSN-L)
- PMC
- PMC2605581
- OpenAlex
- W2127786259
- Cited by
- 1,193
- References
- 99
- Citations by year
- 2026: 66 · 2025: 72 · 2024: 76 · 2023: 103 · 2022: 96 · 2021: 74 · 2020: 87 · 2019: 87 · 2018: 84 · 2017: 93 · 2016: 71 · 2015: 68 · 2014: 65 · 2013: 46 · 2012: 54
- FWCI
- 1.25
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Journal of NeuroEngineering and Rehabilitation (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Physical Sciences › Computer Science › Signal Processing › Direction-of-Arrival Estimation Techniques
- Keywords
- EEG source localization, inverse problems, non-parametric methods, parametric methods, minimum norm estimation, LORETA, sLORETA, S-map, Laura, subspace methods, beamforming, fines, simulated annealing, computational intelligence, source depth, noise level, Monte Carlo comparison
- MeSH terms
- Algorithms, Animals, Brain, Electroencephalography, Humans, Models, Neurological, Models, Theoretical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Review on solving the inverse problem in EEG source analysis. https://app.cochat.ai/papers/10.1186/1743-0003-5-25
- The paper
- Grech, R., Cassar, T., Muscat, J., Camilleri, K. P., Fabri, S. G., Zervakis, M., Xanthopoulos, P., Sakkalis, V., & Vanrumste, B. (2008). Review on solving the inverse problem in EEG source analysis. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/1743-0003-5-25
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.