CoChat

Micromodular implants to provide electrical stimulation of paralyzed muscles and limbs

Cameron, T., Loeb, G.E., Peck, R.A., Schulman, J.H., Strojnik, P., Troyk, P.R. · 1997 · IEEE Transactions on Biomedical Engineering
Cited by 136

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We describe the design, fabrication, and output capabilities of a microminiature electrical stimulator that can be injected in or near nerves and muscles. Each single-channel microstimulator consists of a cylindrical glass capsule with hermetically sealed electrodes in either end (2-mm diameter x 13-mm overall length). Power and digital control data can be transmitted to multiple implants (256 unique addresses) via a 2-MHz RF field created by an external AM oscillator and inductive coil. In vitro testing demonstrated accurate control of output pulsewidth (3-258 microseconds in 1-microseconds steps) and current (0-30 mA in two linear ranges of 16 steps each, up to 8.5 V available compliance voltage). Microstimulators were used successfully for chronic stimulation in hindlimb muscles of cats. Design and fabrication issues affecting yield and reliability of the packaging and electronics are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.623047

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 136

Metadata

Authors
Cameron, T., Loeb, G. E., Peck, R. A., Schulman, J. H., Strojnik, P., & Troyk, P. R.
Venue
IEEE Transactions on Biomedical Engineering
Published
1997
Volume
44
Issue
9
Pages
781-790
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2159200911
Cited by
136
References
3
FWCI
2.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.