The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
ECG beat detection using filter banks
Abstract
We have designed a multirate digital signal processing algorithm to detect heart beats in the electrocardiogram (ECG). The algorithm incorporates a filter bank (FB) which decomposes the ECG into subbands with uniform frequency bandwidths. The FB-based algorithm enables independent time and frequency analysis to be performed on a signal. Features computed from a set of the subbands and a heuristic detection strategy are used to fuse decisions from multiple one-channel beat detection algorithms. The overall beat detection algorithm has a sensitivity of 99.59% and a positive predictivity of 99.56% against the MIT/BIH database. Furthermore this is a real-time algorithm since its beat detection latency is minimal. The FB-based beat detection algorithm also inherently lends itself to a computationally efficient structure since the detection logic operates at the subband rate. The FB-based structure is potentially useful for performing multiple ECG processing tasks using one set of preprocessing filters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Self-citation
Cited by
Heartbeat Classification Using Morphological and Dynamic Features of ECG Signals
Ye, C., Kumar, B. V. K. V., & Coimbra, M. T. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2213253 · Cited by 522
A novel application of deep learning for single-lead ECG classification
Mathews, S. M., Kambhamettu, C., & Barner, K. E. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.013 · Cited by 322
Convolutional Neural Networks for patient-specific ECG classification
Kiranyaz, S., Ince, T., Hamila, R., & Gabbouj, M. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318926 · Cited by 309
Luft, C. D. B., & Bhattacharya, J. (2015) · Scientific Reports · doi:10.1038/srep15717 · Cited by 143
Using photoplethysmography in heart rate monitoring of patients with epilepsy
van Andel, J., Ungureanu, C., Aarts, R., Leijten, F., & Arends, J. (2015) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2015.02.018 · Cited by 39
Metadata
- Authors
- Afonso, V. X., Tompkins, W. J., Nguyen, T. Q., & Luo, S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1999
- Volume
- 46
- Issue
- 2
- Pages
- 192-202
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2104614052
- Cited by
- 728
- References
- 1
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ECG beat detection using filter banks. https://app.cochat.ai/papers/10.1109/10.740882
- The paper
- Afonso, V. X., Tompkins, W. J., Nguyen, T. Q., & Luo, S. (1999). ECG beat detection using filter banks. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.740882
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.