Abstract

We propose a fast and accurate patient-specific electrocardiogram (ECG) classification and monitoring system using an adaptive implementation of 1D Convolutional Neural Networks (CNNs) that can fuse feature extraction and classification into a unified learner. In this way, a dedicated CNN will be trained for each patient by using relatively small common and patient-specific training data and thus it can also be used to classify long ECG records such as Holter registers in a fast and accurate manner. Alternatively, such a solution can conveniently be used for real-time ECG monitoring and early alert system on a light-weight wearable device. The experimental results demonstrate that the proposed system achieves a superior classification performance for the detection of ventricular ectopic beats (VEB) and supraventricular ectopic beats (SVEB).

Overview

Integrity signals

Registry

Crossref · 10.1109/embc.2015.7318926

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 18 references

Research works printed but not linked: 2

  1. 1987, Recommended practice for testing and reporting performance results of ventricular arrhythmia detection algorithms, Association for the Advancement of Medical Instrumentation
  2. talmon, 1983, Pattern Recognition of the ECG

Cited by

See all 319

Metadata

Authors
Kiranyaz, S., Ince, T., Hamila, R., & Gabbouj, M.
Affiliations
  • Qatar University (QA)
  • Tampere University of Technology (FI)
Venue
2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Publisher
IEEE
Published
2015-08
Volume
2015
Pages
2608-2611
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2223222085
Cited by
309
References
18
Citations by year
2026: 12 · 2025: 33 · 2024: 52 · 2023: 51 · 2022: 47 · 2021: 39 · 2020: 37 · 2019: 23 · 2018: 9 · 2017: 5 · 2016: 1
FWCI
12.56
Type
conference paper
Language
en
Open access
closed
Locations
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
  • PubMed (publishedVersion)
  • Qatar University QSpace (Qatar University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
Keywords
1D convolutional neural network, Holter monitoring, premature ventricular contractions, supraventricular ectopic beats, real-time ECG monitoring, wearable devices, early alert systems
MeSH terms
Algorithms, Electrocardiography, Humans, Monitoring, Physiologic, Neural Networks, Computer, Ventricular Premature Complexes, Atrial Premature Complexes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Convolutional Neural Networks for patient-specific ECG classification. https://app.cochat.ai/papers/10.1109/embc.2015.7318926
The paper
Kiranyaz, S., Ince, T., Hamila, R., & Gabbouj, M. (2015). Convolutional Neural Networks for patient-specific ECG classification. 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). https://doi.org/10.1109/embc.2015.7318926

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.