The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Wavelet analysis of oscillations in the peripheral blood circulation measured by laser Doppler technique
Abstract
The wavelet transform technique, a time-frequency method with logarithmic frequency resolution, was used to analyze oscillations in human peripheral blood flow measured by laser Doppler flowmetry. The oscillations extended over a wide frequency scale and their periods varied in time. Within the frequency range studied, 0.0095-1.6 Hz, five characteristic oscillations were revealed, arising from both local and central regulatory mechanisms. After the insertion of endothelium-dependent and endothelium-independent vasodilators the spectra of blood flow markedly differed in the frequency interval 0.0095-0.02 Hz. In this way it was demonstrated that endothelial activity is a rhythmic process that contributes to oscillations in blood flow with a characteristic frequency of around 0.01 Hz. The study illustrates the potential of laser Doppler flowmetry combined with dynamical systems analysis for studies of both the micro- and macroscopic mechanisms of blood flow regulation in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Daubechies, I., & Heil, C. (1992) · Computers in Physics · doi:10.1063/1.4823127 · Cited by 15,631
Nitric oxide: physiology, pathophysiology, and pharmacology.
Moncada, S., Palmer, R. M., & Higgs, E. A. (1991) · Pharmacological Reviews · doi:10.1016/s0031-6997(25)06663-3 · Cited by 15,525
Furchgott, R. F., & Zawadzki, J. V. (1980) · Nature · doi:10.1038/288373a0 · Cited by 12,064
Nitric oxide release accounts for the biological activity of endothelium-derived relaxing factor
Palmer, R. M. J., Ferrige, A. G., & Moncada, S. (1987) · Nature · doi:10.1038/327524a0 · Cited by 10,704
Stimulated Optical Radiation in Ruby
MAIMAN, T. H. (1960) · Nature · doi:10.1038/187493a0 · Cited by 5,121
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Endothelial cells in physiology and in the pathophysiology of vascular disorders.
Cines, D. B., Pollak, E. S., Buck, C. A., Loscalzo, J., Zimmerman, G. A., McEver, R. P., Pober, J. S., Wick, T. M., Konkle, B. A., Schwartz, B. S., et al. (1998) · PubMed · doi:10.1182/blood.v91.10.3527 · Cited by 2,256
Ignarro, L. J., Byrns, R. E., Buga, G. M., & Wood, K. S. (1987) · Circulation Research · doi:10.1161/01.res.61.6.866 · Cited by 1,179
Evaluation of a Laser Doppler Flowmeter for Measurement of Tissue Blood Flow
Nilsson, G. E., Tenland, T., & Oberg, P. A. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326582 · Cited by 1,095
Kaiser, G. (2011) · Birkhäuser Boston eBooks · doi:10.1007/978-0-8176-8111-1 · Cited by 1,078
Biostatistics: A Methodology for the Health Sciences.
D'Agostino, R. B., Fisher, L. D., & van Belle, G. (1995) · Journal of the American Statistical Association · doi:10.2307/2291095 · Cited by 957
The Role of Endothelium in the Responses of Vascular Smooth Muscle to Drugs
Furchgott, R. F. (1984) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev.pa.24.040184.001135 · Cited by 950
In vivo evaluation of microcirculation by coherent light scattering
STERN, M. D. (1975) · Nature · doi:10.1038/254056a0 · Cited by 857
Model for laser Doppler measurements of blood flow in tissue
Bonner, R., & Nossal, R. (1981) · Applied Optics · doi:10.1364/ao.20.002097 · Cited by 836
(1995) · Choice Reviews Online · doi:10.5860/choice.32-4552 · Cited by 732
Sampling Theory and Wave Propagation
Morlet, J. (1983) · Springer eBooks · doi:10.1007/978-3-642-82002-1_12 · Cited by 378
Laser Doppler measurements of blood flow in capillary tubes and retinal arteries.
Riva, C. E., Ross, B., & Benedek, G. B. (1972) · PubMed · Cited by 362
Spontaneous rhythms in physiological control systems
HYNDMAN, B. W., KITNEY, R. I., & SAYERS, B. M. (1971) · Nature · doi:10.1038/233339a0 · Cited by 361
Endothelial dysfunction: Clinical implications
DREXLER, H. (1997) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(97)80030-8 · Cited by 293
Biostatistics: a methodology for the health sciences
(1993) · Choice Reviews Online · doi:10.5860/choice.31-0993 · Cited by 280
Morris, S. J., & Shore, A. C. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021704 · Cited by 254
The Myogenic Response: In Vivo Studies
Johnson, P. C. (1991) · The Resistance Vasculature · doi:10.1007/978-1-4612-0403-9_10 · Cited by 248
Kvernmo, H. D., Stefanovska, A., Kirkebøen, K. A., & Kvernebo, K. (1999) · Microvascular Research · doi:10.1006/mvre.1998.2139 · Cited by 246
Self-citationWavelet-based Analysis of Human Blood-flow Dynamics
Bracic, M. (1998) · Bulletin of Mathematical Biology · doi:10.1006/bulm.1998.0047 · Cited by 236
Self-citationSamson Wright's Applied Physiology
(1962) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1962.tb20411.x · Cited by 216
An Instrument to Measure Cutaneous Blood Flow Using the Doppler Shift of Laser Light
Watkins, D., & Holloway, G. A. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326374 · Cited by 201
Keselbrener, L., & AKSELROD, S. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.508542 · Cited by 154
Kastrup, J., Bülow, J., & Lassen, N. A. (1989) · PubMed · Cited by 145
Schmidt, R. F., & Thews, G. (1989) · Springer eBooks · doi:10.1007/978-3-642-73831-9 · Cited by 134
Transient interactions between blood pressure, respiration and heart rate in man
Kitney, R. I., Fulton, T., Mcdonald, A. H., & Linkenst, D. A. (1985) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(85)90022-6 · Cited by 104
Enhanced vasodilation to acetylcholine in athletes is associated with lower plasma cholesterol
Kingwell, B. A., Tran, B., Cameron, J. D., Jennings, G., & Dart, A. M. (1996) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1996.270.6.h2008 · Cited by 99
Kvernmo, H. D., Stefanovska, A., Kirkebøen, K. A., �sterud, B., & Kvernebo, K. (1998) · European Journal of Applied Physiology · doi:10.1007/s004210050469 · Cited by 64
Self-citationIs High-Frequency Flux Motion due to Respiration or to Vasomotion Activity?1
Bollinger, A., Yanar, A., Hoffmann, U., & Uk, F. (2015) · Mikrozirkulation in Forschung und Klinik/Progress in applied microcirculation · doi:10.1159/000422452 · Cited by 63
Periodic cutaneous blood flow during postocclusive reactive hyperemia
Wilkin, J. K. (1986) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1986.250.5.h765 · Cited by 62
Laser Doppler velocimetry in the measurement of neurovascular function.
Westerman, R. A., Widdop, R. E., Hannaford, J., Low, A. M., Roberts, R. G. D., Kent, P. M., Sideris, K., Yip, T., Hales, J. R. S., & Stephens, F. R. N. (1988) · PubMed · Cited by 44
Computeranalysis of cardiovascular signals.
Mulder, L. J. M., van Roon, A. M., Veldman, J. B. P., & Elgersma, A. (1995) · IOS Press eBooks · Cited by 44
The frequency histogram—A new method for the evaluation of laser doppler flux motion
Hoffmann, U., Yanar, A., Franzeck, U. K., Edwards, J. M., & Bollinger, A. (1990) · Microvascular Research · doi:10.1016/0026-2862(90)90028-p · Cited by 42
Evidence for endothelium-dependent and endothelium-independent vasodilation in human skin flaps
Kreidstein, M. L., Pang, C. Y., Carlsen, L. N., & Xu, N. (1992) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y92-168 · Cited by 26
Müller, P., Keller, R., & Imhof, P. (1987) · PubMed · Cited by 20
Andreassen, A. K., Kirkebøen, K. A., Gullestad, L. L., Simonsen, S., & Kvernebo, K. (1998) · International Journal of Cardiology · doi:10.1016/s0167-5273(98)00103-x · Cited by 18
Cited by
The human cutaneous circulation as a model of generalized microvascular function
Holowatz, L. A., Thompson-Torgerson, C. S., & Kenney, W. L. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00858.2007 · Cited by 476
Surrogate data for hypothesis testing of physical systems
Lancaster, G., Iatsenko, D., Pidde, A., Ticcinelli, V., & Stefanovska, A. (2018) · Physics Reports · doi:10.1016/j.physrep.2018.06.001 · Cited by 422
Self-citationLow-frequency oscillations of the laser Doppler perfusion signal in human skin
Kvandal, P., Landsverk, S. A., Bernjak, A., Stefanovska, A., Kvernmo, H. D., & Kirkebøen, K. A. (2006) · Microvascular Research · doi:10.1016/j.mvr.2006.05.006 · Cited by 366
Self-citationNonlinear dynamics of cardiovascular ageing
Shiogai, Y., Stefanovska, A., & McClintock, P. V. E. (2010) · Physics Reports · doi:10.1016/j.physrep.2009.12.003 · Cited by 321
Self-citationSpectral components of heart rate variability determined by wavelet analysis
Lotric, M. B., Stefanovska, A., Stajer, D., & Urbancic-Rovan, V. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/4/302 · Cited by 80
Self-citation
Metadata
- Authors
- Stefanovska, A., Bracic, M., & Kvernmo, H. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1999
- Volume
- 46
- Issue
- 10
- Pages
- 1230-1239
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2166328099
- Cited by
- 688
- References
- 42
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.