CoChat

Rapid electromagnetic warming of cells and tissues

Robinson, M.P., Pegg, D.E. · 1999 · IEEE Transactions on Biomedical Engineering
Cited by 54

The DOI matches its Crossref record.

Abstract

We describe a system for thawing frozen cell suspensions and tissues by electromagnetic absorption. A 25-ml sample is heated in a cylindrical resonant cavity, which is excited in three modes all close to 434 MHz. Maximum warming rates are over 10 degrees C/s (600 C/min), and a frozen sample may be brought from -65 degrees C to room temperature in < 30 s, with final spatial differences of < 20 degrees C. Samples may be frozen externally, or cooled within the cavity at typically 1 degree C/min. We have also used the resonant cavity to measure the permittivity and conductivity of the sample at temperatures from -83 degrees C to +8 degrees C. By measuring the heat capacity of the sample, we have calculated the power deposited in it as a function of its temperature. The system is currently being used to investigate the effect of warming rate on cell survival.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.804569

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 54

Metadata

Authors
Robinson, M. P., & Pegg, D. E.
Venue
IEEE Transactions on Biomedical Engineering
Published
1999
Volume
46
Issue
12
Pages
1413-1425
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2123600303
Cited by
54
References
0
FWCI
2.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid electromagnetic warming of cells and tissues. https://app.cochat.ai/papers/10.1109/10.804569
The paper
Robinson, M. P., & Pegg, D. E. (1999). Rapid electromagnetic warming of cells and tissues. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.804569

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.