The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Preparation of Scalable Silica‐Coated Iron Oxide Nanoparticles for Nanowarming
Abstract
Cryopreservation technology allows long‐term banking of biological systems. However, a major challenge to cryopreserving organs remains in the rewarming of large volumes (>3 mL), where mechanical stress and ice formation during convective warming cause severe damage. Nanowarming technology presents a promising solution to rewarm organs rapidly and uniformly via inductive heating of magnetic nanoparticles (IONPs) preloaded by perfusion into the organ vasculature. This use requires the IONPs to be produced at scale, heat quickly, be nontoxic, remain stable in cryoprotective agents (CPAs), and be washed out easily after nanowarming. Nanowarming of cells and blood vessels using a mesoporous silica‐coated iron oxide nanoparticle (msIONP) in VS55, a common CPA, has been previously demonstrated. However, production of msIONPs is a lengthy, multistep process and provides only mg Fe per batch. Here, a new microporous silica‐coated iron oxide nanoparticle (sIONP) that can be produced in as little as 1 d while scaling up to 1.4 g Fe per batch is presented. sIONP high heating, biocompatibility, and stability in VS55 is also verified, and the ability to perfusion load and washout sIONPs from a rat kidney as evidenced by advanced imaging and ICP‐OES is demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Rewarming rates scale linearly with IONP concentration.
“supporting prior observations that rewarming rates will scale linearly with IONP concentration29,31,32”
From Physical vitrification and nanowarming at liter-scale CPA volumes: toward organ cryopreservation (2025) · cites this paper as [31]
This is the fastest nanowarming rate that has been measured that we are aware of.
“This is the fastest nanowarming rate that has been measured that we are aware of, supporting prior observations that rewarming rates will scale linearly with IONP concentration29,31,32, which is promising for future development.”
From Physical vitrification and nanowarming at liter-scale CPA volumes: toward organ cryopreservation (2025) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Flagged first, then by citations
Research works printed but not linked: 63
- 10.5500/wjt.v6.i3.451 · DOI
- 10.1038/nbt.3971 · DOI
- 10.1038/nbt.3889 · DOI
- 10.1016/j.cryobiol.2015.12.001 · DOI
- 10.1016/0142-9612(96)85562-1 · DOI
- 10.1016/0011-2240(84)90079-8 · DOI · Paper page
- 10.1006/cryo.1997.2026 · DOI
- 10.4161/org.5.3.9974 · DOI · Paper page
- 10.1016/j.cryobiol.2004.02.002 · DOI · Paper page
- 10.1016/j.cryobiol.2012.05.010 · DOI
- 10.1016/0011-2240(90)90038-6 · DOI · Paper page
- 10.1016/0011-2240(90)90035-3 · DOI · Paper page
- 10.1109/10.804569 · DOI
- 10.1016/0011-2240(78)90020-2 · DOI · Paper page
- 10.1016/0011-2240(80)90046-2 · DOI
- 10.1088/0031-9155/47/13/309 · DOI · Paper page
- 10.1016/0011-2240(77)90166-3 · DOI
- 10.1016/0011-2240(78)90086-X · DOI
- 10.1006/cryo.1993.1050 · DOI
- 10.1006/cryo.2000.2232 · DOI
- Evans S., 1993, J. Microwave Power, 28, 84
- 10.1109/22.884213 · DOI
- 10.3109/15368378509033258 · DOI
- 10.1142/S2339547814500204 · DOI · Paper page
- 10.1126/scitranslmed.aah4586 · DOI · Paper page
- 10.1016/j.cryobiol.2018.10.236 · DOI
- 10.1021/acs.langmuir.8b03060 · DOI
- 10.1038/srep01652 · DOI
- Moros E., 2012, Physics of Thermal Therapy: Fundamentals and Clinical Applications
- 10.1038/s41598-018-19628-z · DOI
- 10.1142/S2339547814500198 · DOI · Paper page
- 10.1021/acs.molpharmaceut.5b00866 · DOI
- 10.1002/mrm.26394 · DOI
- 10.1002/mrm.26800 · DOI
- 10.1002/mrm.25181 · DOI
- 10.1016/0021-9797(68)90272-5 · DOI
- 10.1021/ja208567v · DOI
- 10.1021/la0347859 · DOI
- 10.1021/nl015681q · DOI
- 10.1021/acsnano.7b05182 · DOI
- 10.1021/nn505781f · DOI
- 10.1021/jp410717m · DOI
- 10.1021/la00023a051 · DOI
- 10.1006/jcis.2000.6860 · DOI
- 10.1021/cm4039945 · DOI
- 10.1039/b401471e · DOI
- 10.1016/j.micromeso.2005.05.001 · DOI
- 10.1016/j.jssc.2014.03.004 · DOI
- 10.1016/j.talanta.2007.05.039 · DOI
- Macher T., 2015, J. Nanomater., 16, 143
- 10.3390/ijms13066639 · DOI
- Beganskienė A., 2004, Mater. Sci., 10, 287
- 10.1021/nl8016187 · DOI
- Schwarz W., 1990, PVP: A Critical Review of the Kinetics and Toxicology of Polyvinylpyrrolidone (Povidone)
- Kwon S. K., 2006, J. Korean Phys. Soc., 49, 1421
- 10.1109/TMAG.1986.1064535 · DOI
- 10.1089/bio.2018.0006 · DOI
- Xu Y., 2016, CryoLetters, 37, 448
- 10.1007/s40242-019-8230-6 · DOI
- 10.1021/jp2086413 · DOI
- 10.1016/j.jmr.2014.11.014 · DOI
- 10.1063/1.5001359 · DOI
- 10.1002/mrm.24831 · DOI
Cited by
Sorted by citations
Han, Z., Rao, J. S., Gangwar, L., Namsrai, B.-E., Pasek-Allen, J. L., Etheridge, M. L., Wolf, S. M., Pruett, T. L., Bischof, J. C., & Finger, E. B. (2023) · Nature Communications · doi:10.1038/s41467-023-38824-8 · Cited by 173
Self-citationPhysical vitrification and nanowarming at liter-scale CPA volumes: toward organ cryopreservation
Gangwar, L., Han, Z., Scheithauer, C., Namsrai, B.-E., Kantesaria, S., Goldstein, R., Etheridge, M. L., Finger, E. B., & Bischof, J. C. (2025) · Nature Communications · doi:10.1038/s41467-025-63483-2 · Cited by 26
Self-citation
Metadata
- Authors
- Gao, Z., Ring, H. L., Sharma, A., Namsrai, B., Tran, N., Finger, E. B., Garwood, M., Haynes, C. L., & Bischof, J. C.
- Affiliations
- Department of Mechanical Engineering University of Minnesota 111 Church St. Minneapolis MN 55455 USA
- Center for Magnetic Resonance Research Department of Radiology University of Minnesota 2021 6th Street S.E. Minneapolis MN 55455 USA
- Department of Surgery University of Minnesota 420 Delaware Street SE Minneapolis MN 55455 USA
- Department of Chemistry University of Minnesota 207 Pleasant St SE Minneapolis MN 55455 USA
- ORCID
- Gao, Zhe
- Venue
- Advanced Science
- Publisher
- Wiley
- Published
- 2020-01-07
- Volume
- 7
- Issue
- 4
- ISSN
- 2198-3844
- PMC
- PMC7029634
- Cited by
- 101
- References
- 1
- Language
- en
- Funders
- National Science Foundation
- W. M. Keck Foundation
- National Institutes of Health (EB027061, R01 HL135046, R01 DK117425)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review