The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier
Abstract
A new sensitive microwave life-detection system which can be used to locate human subjects buried under earthquake rubble or hidden behind various barriers has been constructed. This system operating at 1150 MHz or 450 MHz can detect the breathing and heartbeat signals of human subjects through an earthquake rubble or a construction barrier of about 10-ft thickness. The basic physical principle for the operation of a microwave life-detection system is rather simple. When a microwave beam of appropriate frequency (L or S band) is aimed at a pile of earthquake rubble covering a human subject or illuminated through a barrier obstructing a human subject, the microwave beam can penetrate the rubble or the barrier to reach the human subject. When the human subject is illuminated by a microwave beam, the reflected wave from the human subject will be modulated by the subject's body movements, which include the breathing and the heartbeat. If the clutter consisting of the reflected wave from stationary background can be completely eliminated and the reflected wave from the human subject's body is properly modulated, the breathing and heartbeat signals of the subject can be extracted. Thus, a human subject buried under earthquake rubble or hidden behind barriers can be located. This system has been tested extensively in a simulated earthquake rubble in the laboratory and also in a field test using realistic earthquake rubble conducted by a Federal Emergency Management Agency (FEMA) Task Force.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An X-Band Microwave Life-Detection System
Chen, K., Misra, D. K., Wang, H., Chuang, H.-R., & Postow, E. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325760 · Cited by 284
Self-citation
Cited by
Random Body Movement Cancellation in Doppler Radar Vital Sign Detection
Li, C., & Lin, J. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.2007139 · Cited by 448
Heart rate measurement based on a time-lapse image.
Takano, C., & Ohta, Y. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.09.006 · Cited by 345
DoppleSleep: a contactless unobtrusive sleep sensing system using short-range Doppler radar
Rahman, T., Adams, A. T., Ravichandran, R. V., Zhang, M., Patel, S. N., Kientz, J. A., & Choudhury, T. (2015) · Proceedings of the 2015 ACM International Joint Conference on Pervasive and Ubiquitous Computing · doi:10.1145/2750858.2804280 · Cited by 175
Metadata
- Authors
- Chen, K.-M., Huang, Y., Zhang, J., & Norman, A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000-01
- Volume
- 47
- Issue
- 1
- Pages
- 105-114
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2163232697
- Cited by
- 445
- References
- 1
- FWCI
- 0.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier. https://app.cochat.ai/papers/10.1109/10.817625
- The paper
- Chen, K.-M., Huang, Y., Zhang, J., & Norman, A. (2000). Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.817625
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).