The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Random Body Movement Cancellation in Doppler Radar Vital Sign Detection
Abstract
The complex signal demodulation and the arctangent demodulation are studied for random body movement cancellation in quadrature Doppler radar noncontact vital sign detection. This technique can be used in sleep apnea monitor, lie detector, and baby monitor to eliminate the false alarm caused by random body movement. It is shown that if the dc offset of the baseband signal is accurately calibrated, both demodulation techniques can be used for random body movement cancellation. While the complex signal demodulation is less likely to be affected by a dc offset, the arctangent demodulation has the advantage of eliminating harmonic and intermodulation interference at high carrier frequencies. When the dc offset cannot be accurately calibrated, the complex signal demodulation is more favorable. Ray-tracing model is used to show the effects of constellation deformation and optimum/null detection ambiguity caused by the phase offset due to finite antenna directivity. Experiments have been performed using 4-7 GHz radar to verify the theory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Droitcour, A. D., Boric-Lubecke, O., Lubecke, V. M., Lin, J., & Kovacs, G. T. A. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.823552 · Cited by 662
Self-citationArctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems
Park, B.-K., Boric-Lubecke, O., & Lubecke, V. M. (2007) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2007.895653 · Cited by 604
Chen, K.-M., Huang, Y., Zhang, J., & Norman, A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.817625 · Cited by 445
Microwave sensing of physiological movement and volume change: A review
Lin, J. C. (1992) · Bioelectromagnetics · doi:10.1002/bem.2250130610 · Cited by 299
Self-citationXiao, Y., Lin, J., Boric-Lubecke, O., & Lubecke, M. (2006) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2006.873625 · Cited by 259
Self-citationLi, C., Xiao, Y., & Lin, J. (2006) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2006.884652 · Cited by 245
Self-citationLi, C., & Lin, J. (2008) · 2008 IEEE MTT-S International Microwave Symposium Digest · doi:10.1109/mwsym.2008.4633229 · Cited by 192
Self-citationRange correlation effects on phase and amplitude noise
Budge, M. C., & Burt, M. P. (2002) · Proceedings of IEEE Southeastcon · doi:10.1109/secon.1993.465731 · Cited by 76
Design Guidelines for Radio Frequency Non-contact Vital Sign Detection
Li, C., Xiao, Y., & Lin, J. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352624 · Cited by 24
Self-citation
Cited by
Wireless Sensing for Human Activity: A Survey
Liu, J., Liu, H., Chen, Y., Wang, Y., & Wang, C. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2019.2934489 · Cited by 414
Vital signs monitoring of multiple people using a FMCW millimeter-wave sensor
Ahmad, A., Roh, J. C., Wang, D., & Dubey, A. (2018) · 2018 IEEE Radar Conference (RadarConf18) · doi:10.1109/radar.2018.8378778 · Cited by 313
Metadata
- Authors
- Li, C., & Lin, J.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2008-12
- Volume
- 56
- Issue
- 12
- Pages
- 3143-3152
- ISSN
- 0018-9480 (ISSN-L)
- 1557-9670
- OpenAlex
- W2045727797
- Cited by
- 448
- References
- 9
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Random Body Movement Cancellation in Doppler Radar Vital Sign Detection. https://app.cochat.ai/papers/10.1109/tmtt.2008.2007139
- The paper
- Li, C., & Lin, J. (2008). Random Body Movement Cancellation in Doppler Radar Vital Sign Detection. IEEE Transactions on Microwave Theory and Techniques. https://doi.org/10.1109/tmtt.2008.2007139
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.