CoChat

Multivariate dynamic analysis of cerebral blood flow regulation in humans

Panerai, R.B., Simpson, D.M., Deverson, S.T., Mahony, P., Hayes, P., Evans, D.H. · 2000 · IEEE Transactions on Biomedical Engineering
Cited by 127

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The contributions of beat-to-beat changes in mean arterial blood pressure (MABP) and breath-by-breath fluctuations in end-tidal CO2 (EtCO2) as determinants of the spontaneous variability of cerebral blood flow velocity (CBFV) were studied in 16 normal subjects at rest. The two input variables (MABP and EtCO2) had significant cross-correlations with CBFV but not between them. Transfer functions were estimated as the multivariate least mean square finite impulse response causal filters. MABP showed a very significant effect in explaining CBFV variability (p < 10(-11), Fisher's aggregated-p test) and the model mean square error was significantly reduced (p < 0.001) by also including the contribution of EtCO2. The estimated mean CBFV step response to MABP displayed the characteristic return to baseline caused by the cerebral autoregulatory response. The corresponding response to EtCO2 showed a gradual rise taking approximately 10 s to reach a plateau of 2.5%/mmHg. This study demonstrated that spontaneous fluctuations in EtCO2 can help to explain the CBFV variability at rest if appropriate signal processing techniques are employed to address the limited power and bandwith of the breath-by-breath EtCO2 signal.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.827312

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Panerai, R. B., Simpson, D. M., Deverson, S. T., Mahony, P., Hayes, P., & Evans, D. H.
Venue
IEEE Transactions on Biomedical Engineering
Published
2000-03
Volume
47
Issue
3
Pages
419-423
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2128982389
Cited by
127
References
1
FWCI
4.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.