Cited by 76Heart Rate Variability and Autonomic ControlCardiovascular Syncope and Autonomic DisordersTraumatic Brain Injury and Neurovascular Disturbances

The DOI matches its Crossref record.

Cerebral hemodynamics during orthostatic stress assessed by nonlinear modeling

Abstract

The effects of orthostatic stress, induced by lower body negative pressure (LBNP), on cerebral hemodynamics were examined in a nonlinear context. Spontaneous fluctuations of beat-to-beat mean arterial blood pressure (MABP) in the finger, mean cerebral blood flow velocity (MCBFV) in the middle cerebral artery, as well as breath-by-breath end-tidal CO 2 concentration (Pet CO 2) were measured continuously in 10 healthy subjects under resting conditions and during graded LBNP to presyncope. A two-input nonlinear Laguerre-Volterra network model was employed to study the dynamic effects of MABP and Pet CO 2changes, as well as their nonlinear interactions, on MCBFV variations in the very low (VLF; below 0.04 Hz), low (LF; 0.04–0.15 Hz), and high frequency (HF; 0.15–0.30 Hz) ranges. Dynamic cerebral autoregulation was described by the model terms corresponding to MABP, whereas cerebral vasomotor reactivity was described by the model Pet CO 2terms. The nonlinear model terms reduced the output prediction normalized mean square error substantially (by 15–20%) and had a prominent effect in the VLF range, both under resting conditions and during LBNP. Whereas MABP fluctuations dominated in the HF range and played a significant role in the VLF and LF ranges, changes in Pet CO 2accounted for a considerable fraction of the VLF and LF MCBFV variations, especially at high LBNP levels. The magnitude of the linear and nonlinear MABP-MCBFV Volterra kernels increased substantially above −30 mmHg LBNP in the VLF range, implying impaired dynamic autoregulation. In contrast, the magnitude of the Pet CO 2-MCBFV kernels reduced during LBNP at all frequencies, suggesting attenuated cerebral vasomotor reactivity under dynamic conditions. We speculate that these changes may reflect a progressively reduced cerebrovascular reserve to compensate for the increasingly unstable systemic circulation during orthostatic stress that could ultimately lead to cerebral hypoperfusion and syncope.

Overview

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00548.2005

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In healthy individuals under higher levels of orthostatic stress, PCO2 changes explain substantially more of the variance in cerebral blood flow than mean arterial blood pressure changes.

    “In addition, in healthy individuals under higher levels of orthostatic stress, PCO2 changes explain substantially more of the variance in CBF than mean arterial BP changes (Mitsis et al., 2006).”

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 53

  1. 10.3171/jns.1982.57.6.0769 · DOI
  2. 10.1161/01.STR.20.1.45 · DOI
  3. 10.1161/01.STR.28.9.1686 · DOI
  4. 10.1161/01.STR.26.10.1794 · DOI
  5. 10.1152/jappl.1996.81.1.7 · DOI · Paper page
  6. 10.1161/hc3301.094908 · DOI
  7. 10.1109/10.488800 · DOI
  8. 10.1109/10.661159 · DOI
  9. 10.1152/ajprenal.1994.267.1.F160 · DOI
  10. 10.1016/S0735-1097(02)01719-9 · DOI · Paper page
  11. Edvinsson Land Krause DN.Cerebral Blood Flow and Metabolism. Philadelphia, PA: Lippincott Williams and Wilkins, 2002.
  12. 10.1152/ajpregu.00452.2001 · DOI
  13. 10.1152/ajpregu.00601.2002 · DOI
  14. 10.1111/j.1748-1716.1987.tb08054.x · DOI
  15. 10.1227/00006123-199009000-00004 · DOI
  16. 10.1161/01.CIR.84.3.1157 · DOI
  17. 10.1161/01.RES.42.3.295 · DOI
  18. 10.1093/cvr/24.3.214 · DOI
  19. 10.1152/jappl.1999.86.5.1552 · DOI
  20. 10.1161/01.HYP.36.3.383 · DOI
  21. 10.1152/ajpregu.2000.279.1.R118 · DOI
  22. 10.1097/00004647-199803000-00010 · DOI
  23. 10.1161/01.STR.25.10.1985 · DOI
  24. 10.1113/jphysiol.2003.046987 · DOI
  25. 10.1152/jappl.1991.70.1.112 · DOI
  26. 10.1161/01.CIR.90.1.298 · DOI · Paper page
  27. 10.1007/BF02367386 · DOI
  28. 10.1007/BF02368639 · DOI
  29. Marmarelis VZ.Nonlinear Dynamic Modeling of Physiological Systems.Piscataway, NJ: IEEE-Wiley, 2004. · DOI
  30. 10.1114/1.1458591 · DOI
  31. Mitsis GDand Marmarelis VZ.Nonlinear modeling of physiological systems with multiple inputs.Proc 2nd Joint Meet IEEE EMBS/BMES, Houston, TX, 2002,vol. 1, p. 21–22. · DOI
  32. 10.1114/1.1477448 · DOI
  33. 10.1109/TBME.2004.834272 · DOI
  34. 10.1161/01.STR.25.4.793 · DOI
  35. 10.1161/01.HYP.22.1.26 · DOI
  36. 10.1007/BF02522477 · DOI
  37. 10.1152/ajpheart.1999.277.3.H1089 · DOI
  38. 10.1109/10.827312 · DOI
  39. 10.1152/jappl.1996.81.3.1084 · DOI
  40. 10.1161/01.STR.27.12.2244 · DOI
  41. 10.1161/01.RES.43.4.485 · DOI
  42. 10.1046/j.1440-1681.2002.03614.x · DOI
  43. 10.1152/jappl.1990.68.4.1727 · DOI
  44. 10.1161/01.STR.28.8.1564 · DOI
  45. 10.1152/jappl.2001.91.6.2493 · DOI
  46. 10.1016/0006-8993(79)90008-8 · DOI
  47. 10.1161/01.STR.31.7.1672 · DOI
  48. Sjöberg J.Non-linear System Identification With Neural Networks(PhD thesis). Linköping, Sweden: Linköping University, 1995.
  49. 10.1152/jappl.1997.83.1.312 · DOI
  50. 10.1152/ajpheart.1998.274.1.H233 · DOI
  51. 10.1152/jappl.1998.85.3.1113 · DOI · Paper page
  52. 10.1161/01.CIR.0000031798.07790.FE · DOI
  53. 10.1109/TBME.2003.820401 · DOI

Cited by

Sorted by citations

Metadata

Authors
Mitsis, G. D., Zhang, R., Levine, B. D., & Marmarelis, V. Z.
Affiliations
University of Southern California (US)
Venue
Journal of Applied Physiology
Published
2006-07
Volume
101
Issue
1
Pages
354-366
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2115271383
Cited by
76
References
0
Citations by year
2025: 1 · 2024: 3 · 2023: 1 · 2022: 1 · 2021: 3 · 2020: 3 · 2019: 1 · 2018: 5 · 2017: 4 · 2016: 5 · 2015: 1 · 2014: 7 · 2013: 5 · 2012: 6
FWCI
5.21
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Clinical Neurology › Traumatic Brain Injury and Neurovascular Disturbances
Keywords
cerebral hemodynamics, orthostatic stress, lower body negative pressure, dynamic cerebral autoregulation, cerebrovascular reactivity, end-tidal carbon dioxide, mean arterial pressure, middle cerebral artery blood flow velocity, cerebrovascular reserve, syncope, presyncope
MeSH terms
Adult, Blood Flow Velocity, Blood Pressure, Carbon Dioxide, Cerebrovascular Circulation, Dizziness, Hemodynamics, Homeostasis, Humans, Lower Body Negative Pressure, Male, Models, Theoretical, Rest, Retrospective Studies, Tidal Volume, Vasomotor System, Nonlinear Dynamics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review