The DOI matches its Crossref record.
Cerebral hemodynamics during orthostatic stress assessed by nonlinear modeling
Abstract
The effects of orthostatic stress, induced by lower body negative pressure (LBNP), on cerebral hemodynamics were examined in a nonlinear context. Spontaneous fluctuations of beat-to-beat mean arterial blood pressure (MABP) in the finger, mean cerebral blood flow velocity (MCBFV) in the middle cerebral artery, as well as breath-by-breath end-tidal CO 2 concentration (Pet CO 2) were measured continuously in 10 healthy subjects under resting conditions and during graded LBNP to presyncope. A two-input nonlinear Laguerre-Volterra network model was employed to study the dynamic effects of MABP and Pet CO 2changes, as well as their nonlinear interactions, on MCBFV variations in the very low (VLF; below 0.04 Hz), low (LF; 0.04–0.15 Hz), and high frequency (HF; 0.15–0.30 Hz) ranges. Dynamic cerebral autoregulation was described by the model terms corresponding to MABP, whereas cerebral vasomotor reactivity was described by the model Pet CO 2terms. The nonlinear model terms reduced the output prediction normalized mean square error substantially (by 15–20%) and had a prominent effect in the VLF range, both under resting conditions and during LBNP. Whereas MABP fluctuations dominated in the HF range and played a significant role in the VLF and LF ranges, changes in Pet CO 2accounted for a considerable fraction of the VLF and LF MCBFV variations, especially at high LBNP levels. The magnitude of the linear and nonlinear MABP-MCBFV Volterra kernels increased substantially above −30 mmHg LBNP in the VLF range, implying impaired dynamic autoregulation. In contrast, the magnitude of the Pet CO 2-MCBFV kernels reduced during LBNP at all frequencies, suggesting attenuated cerebral vasomotor reactivity under dynamic conditions. We speculate that these changes may reflect a progressively reduced cerebrovascular reserve to compensate for the increasingly unstable systemic circulation during orthostatic stress that could ultimately lead to cerebral hypoperfusion and syncope.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In healthy individuals under higher levels of orthostatic stress, PCO2 changes explain substantially more of the variance in cerebral blood flow than mean arterial blood pressure changes.
“In addition, in healthy individuals under higher levels of orthostatic stress, PCO2 changes explain substantially more of the variance in CBF than mean arterial BP changes (Mitsis et al., 2006).”
From The psychophysiology of blood-injection-injury phobia: Looking beyond the diphasic response paradigm (2010) · cites this paper as Mitsis et al., 2006
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 53
- 10.3171/jns.1982.57.6.0769 · DOI
- 10.1161/01.STR.20.1.45 · DOI
- 10.1161/01.STR.28.9.1686 · DOI
- 10.1161/01.STR.26.10.1794 · DOI
- 10.1152/jappl.1996.81.1.7 · DOI · Paper page
- 10.1161/hc3301.094908 · DOI
- 10.1109/10.488800 · DOI
- 10.1109/10.661159 · DOI
- 10.1152/ajprenal.1994.267.1.F160 · DOI
- 10.1016/S0735-1097(02)01719-9 · DOI · Paper page
- Edvinsson Land Krause DN.Cerebral Blood Flow and Metabolism. Philadelphia, PA: Lippincott Williams and Wilkins, 2002.
- 10.1152/ajpregu.00452.2001 · DOI
- 10.1152/ajpregu.00601.2002 · DOI
- 10.1111/j.1748-1716.1987.tb08054.x · DOI
- 10.1227/00006123-199009000-00004 · DOI
- 10.1161/01.CIR.84.3.1157 · DOI
- 10.1161/01.RES.42.3.295 · DOI
- 10.1093/cvr/24.3.214 · DOI
- 10.1152/jappl.1999.86.5.1552 · DOI
- 10.1161/01.HYP.36.3.383 · DOI
- 10.1152/ajpregu.2000.279.1.R118 · DOI
- 10.1097/00004647-199803000-00010 · DOI
- 10.1161/01.STR.25.10.1985 · DOI
- 10.1113/jphysiol.2003.046987 · DOI
- 10.1152/jappl.1991.70.1.112 · DOI
- 10.1161/01.CIR.90.1.298 · DOI · Paper page
- 10.1007/BF02367386 · DOI
- 10.1007/BF02368639 · DOI
- Marmarelis VZ.Nonlinear Dynamic Modeling of Physiological Systems.Piscataway, NJ: IEEE-Wiley, 2004. · DOI
- 10.1114/1.1458591 · DOI
- Mitsis GDand Marmarelis VZ.Nonlinear modeling of physiological systems with multiple inputs.Proc 2nd Joint Meet IEEE EMBS/BMES, Houston, TX, 2002,vol. 1, p. 21–22. · DOI
- 10.1114/1.1477448 · DOI
- 10.1109/TBME.2004.834272 · DOI
- 10.1161/01.STR.25.4.793 · DOI
- 10.1161/01.HYP.22.1.26 · DOI
- 10.1007/BF02522477 · DOI
- 10.1152/ajpheart.1999.277.3.H1089 · DOI
- 10.1109/10.827312 · DOI
- 10.1152/jappl.1996.81.3.1084 · DOI
- 10.1161/01.STR.27.12.2244 · DOI
- 10.1161/01.RES.43.4.485 · DOI
- 10.1046/j.1440-1681.2002.03614.x · DOI
- 10.1152/jappl.1990.68.4.1727 · DOI
- 10.1161/01.STR.28.8.1564 · DOI
- 10.1152/jappl.2001.91.6.2493 · DOI
- 10.1016/0006-8993(79)90008-8 · DOI
- 10.1161/01.STR.31.7.1672 · DOI
- Sjöberg J.Non-linear System Identification With Neural Networks(PhD thesis). Linköping, Sweden: Linköping University, 1995.
- 10.1152/jappl.1997.83.1.312 · DOI
- 10.1152/ajpheart.1998.274.1.H233 · DOI
- 10.1152/jappl.1998.85.3.1113 · DOI · Paper page
- 10.1161/01.CIR.0000031798.07790.FE · DOI
- 10.1109/TBME.2003.820401 · DOI
Cited by
Sorted by citations
Ocon, A. J., Medow, M. S., Taneja, I., Clarke, D., & Stewart, J. M. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00138.2009 · Cited by 105
The psychophysiology of blood-injection-injury phobia: Looking beyond the diphasic response paradigm
Ritz, T., Meuret, A. E., & Ayala, E. S. (2010) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2010.05.007 · Cited by 74
Metadata
- Authors
- Mitsis, G. D., Zhang, R., Levine, B. D., & Marmarelis, V. Z.
- Affiliations
- University of Southern California (US)
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2006-07
- Volume
- 101
- Issue
- 1
- Pages
- 354-366
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2115271383
- Cited by
- 76
- References
- 0
- Citations by year
- 2025: 1 · 2024: 3 · 2023: 1 · 2022: 1 · 2021: 3 · 2020: 3 · 2019: 1 · 2018: 5 · 2017: 4 · 2016: 5 · 2015: 1 · 2014: 7 · 2013: 5 · 2012: 6
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Clinical Neurology › Traumatic Brain Injury and Neurovascular Disturbances
- Keywords
- cerebral hemodynamics, orthostatic stress, lower body negative pressure, dynamic cerebral autoregulation, cerebrovascular reactivity, end-tidal carbon dioxide, mean arterial pressure, middle cerebral artery blood flow velocity, cerebrovascular reserve, syncope, presyncope
- MeSH terms
- Adult, Blood Flow Velocity, Blood Pressure, Carbon Dioxide, Cerebrovascular Circulation, Dizziness, Hemodynamics, Homeostasis, Humans, Lower Body Negative Pressure, Male, Models, Theoretical, Rest, Retrospective Studies, Tidal Volume, Vasomotor System, Nonlinear Dynamics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review