The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Improved heart rate variability signal analysis from the beat occurrence times according to the IPFM model
Abstract
The heart rate variability (HRV) is an extended tool to analyze the mechanisms controlling the cardiovascular system. In this paper, the integral pulse frequency modulation model (IPFM) is assumed. It generates the beat occurrence times from a modulating signal. This signal is thought to represent the autonomic nervous system action, mostly studied in its frequency components. Different spectral estimation methods try to infer the modulating signal characteristics from the available beat timing on the electrocardiogram signal. These methods estimate the spectrum through the heart period (HP) or the heart rate (HR) signal. We introduce a new time domain HRV signal, the Heart Timing (HT) signal. We demonstrate that this HT signal, in contrast with the HR or HP, makes it possible to recover an unbiased estimation of the modulating signal spectra. In this estimation we avoid the spurious components and the low-pass filtering effect generated when analyzing HR or HP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Cited by
Software for advanced HRV analysis
Niskanen, J.-P., Tarvainen, M. P., Ranta-aho, P. O., & Karjalainen, P. A. (2004) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2004.03.004 · Cited by 743
Short‐term cardiovascular oscillations in man: measuring and modelling the physiologies
Cohen, M. A., & Taylor, J. A. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2002.017483 · Cited by 362
Analysis of heart rate variability in the presence of ectopic beats using the heart timing signal
Mateo, J., & Laguna, P. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808831 · Cited by 288
Self-citationReview and classification of variability analysis techniques with clinical applications
Bravi, A., Longtin, A., & Seely, A. J. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-90 · Cited by 265
Heartbeat Time Series Classification With Support Vector Machines
Kampouraki, A., Manis, G., & Nikou, C. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2003323 · Cited by 254
Metadata
- Authors
- Mateo, J., & Laguna, P.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000
- Volume
- 47
- Issue
- 8
- Pages
- 985-996
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2125873479
- Cited by
- 170
- References
- 4
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved heart rate variability signal analysis from the beat occurrence times according to the IPFM model. https://app.cochat.ai/papers/10.1109/10.855925
- The paper
- Mateo, J., & Laguna, P. (2000). Improved heart rate variability signal analysis from the beat occurrence times according to the IPFM model. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.855925
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.