CoChat

Magnetic stimulation coil and circuit design

Davey, K., Epstein, C.M. · 2000 · IEEE Transactions on Biomedical Engineering
Cited by 83

The DOI matches its Crossref record.

Abstract

A detailed analysis of the membrane voltage rise commensurate with the electrical charging circuit of a typical magnetic stimulator is presented. The analysis shows how the membrane voltage is linked to the energy, reluctance, and resonant frequency of the electrical charging circuit. There is an optimum resonant frequency for any nerve membrane depending on its capacitive time constant. The analysis also shows why a larger membrane voltage will be registered on the second phase of a biphasic pulse excitation [1]. Typical constraints on three key quantities voltage, current, and silicone controlled rectifier (SCR) switching time dictate key components such as capacitance, inductance, and choice of turns.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.880101

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 83

Metadata

Authors
Davey, K., & Epstein, C. M.
Venue
IEEE Transactions on Biomedical Engineering
Published
2000
Volume
47
Issue
11
Pages
1493-1499
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2105809349
Cited by
83
References
0
FWCI
0.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic stimulation coil and circuit design. https://app.cochat.ai/papers/10.1109/10.880101
The paper
Davey, K., & Epstein, C. M. (2000). Magnetic stimulation coil and circuit design. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.880101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.