Magnetic stimulation coil and circuit design
The DOI matches its Crossref record.
Abstract
A detailed analysis of the membrane voltage rise commensurate with the electrical charging circuit of a typical magnetic stimulator is presented. The analysis shows how the membrane voltage is linked to the energy, reluctance, and resonant frequency of the electrical charging circuit. There is an optimum resonant frequency for any nerve membrane depending on its capacitive time constant. The analysis also shows why a larger membrane voltage will be registered on the second phase of a biphasic pulse excitation [1]. Typical constraints on three key quantities voltage, current, and silicone controlled rectifier (SCR) switching time dictate key components such as capacitance, inductance, and choice of turns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rossi, S., Hallett, M., Rossini, P. M., & Pascual-Leone, A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.08.016 · Cited by 5,367
“This effect can be explained in terms of the delayed (capacitive) response of the membrane (Davey and Epstein, 2000; Corthout et al., 2001).”
BackgroundPeterchev, A. V., Wagner, T. A., Miranda, P. C., Nitsche, M. A., Paulus, W., Lisanby, S. H., Pascual-Leone, A., & Bikson, M. (2012) · Brain Stimulation · doi:10.1016/j.brs.2011.10.001 · Cited by 429
Pell, G. S., Roth, Y., & Zangen, A. (2011) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.10.003 · Cited by 406
Lisanby, S. H., Husain, M. M., Rosenquist, P. B., Maixner, D., Gutierrez, R., Krystal, A., Gilmer, W., Marangell, L. B., Aaronson, S., Daskalakis, Z. J., et al. (2009) · Neuropsychopharmacology · doi:10.1038/npp.2008.118 · Cited by 333
“Other treatment factors related to neurophysiological responses to TMS include coil and stimulator type, waveform shape and polarity, coil position, and orientation relative to target cortex (Davey and Epstein, 2000; Kammer et al, 2001a, b; Maccabee et al, 1998; Thielscher and Kammer, 2004).”
BackgroundCoil design considerations for deep transcranial magnetic stimulation
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.11.038 · Cited by 308
Metadata
- Authors
- Davey, K., & Epstein, C. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000
- Volume
- 47
- Issue
- 11
- Pages
- 1493-1499
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2105809349
- Cited by
- 83
- References
- 0
- FWCI
- 0.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic stimulation coil and circuit design. https://app.cochat.ai/papers/10.1109/10.880101
- The paper
- Davey, K., & Epstein, C. M. (2000). Magnetic stimulation coil and circuit design. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.880101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.