The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Time-frequency parameters of the surface myoelectric signal for assessing muscle fatigue during cyclic dynamic contractions
Abstract
The time-dependent shift in the spectral content of the surface myoelectric signal to lower frequencies has proven to be a useful tool for assessing localized muscle fatigue. Unfortunately, the technique has been restricted to constant-force, isometric contractions because of limitations in the processing methods used to obtain spectral estimates. A novel approach is proposed for calculating spectral parameters from the surface myoelectric signal during cyclic dynamic contractions. The procedure was developed using Cohen class time-frequency transforms to define the instantaneous median and mean frequency during cyclic dynamic contractions. Changes in muscle length, force, and electrode position contribute to the nonstationarity of the surface myoelectric signal. These factors, unrelated to localized fatigue, can be constrained and isolated for cyclic dynamic contractions, where they are assumed to be constant for identical phases of each cycle. Estimation errors for the instantaneous median and mean frequency are calculated from synthesized signals. It is shown that the instantaneous median frequency is affected by an error slightly lower than that related to the instantaneous mean frequency. In addition, we present a sample application to surface myoelectric signals recorded from the first dorsal interosseous muscle during repetitive abduction/adduction of the index finger against resistance. Results indicate that the variability of the instantaneous median frequency is related to the repeatability of the biomechanics of the exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Discrete-Time Signal Processing
Oppenheim, A. V., & Schafer, R. W. (1989) · Cited by 12,572
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268
Self-citation(2009) · Encyclopedia of Neuroscience · doi:10.1007/978-3-540-29678-2_6014 · Cited by 2,850
(1996) · Adapted Wavelet Analysis · doi:10.1201/9781439863619-15 · Cited by 2,703
Improved time-frequency representation of multicomponent signals using exponential kernels
Choi, H.-I., & Williams, W. J. (1989) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/assp.1989.28057 · Cited by 1,299
Myoelectrical manifestations of localized muscular fatigue in humans.
Luca, C. J. D. (1984) · PubMed · Cited by 1,097
Frequency Parameters of the Myoelectric Signal as a Measure of Muscle Conduction Velocity
Stulen, F. B., & De Luca, C. J. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324738 · Cited by 576
Self-citationWigner-Ville spectral analysis of nonstationary processes
Martin, W., & Flandrin, P. (1985) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1985.1164760 · Cited by 554
Interpretation of myoelectric power spectra: A model and its applications
Lindstrom, L. H., & Magnusson, R. I. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10544 · Cited by 419
Kernel design for reduced interference distributions
Jeong, J., & Williams, W. J. (1992) · IEEE Transactions on Signal Processing · doi:10.1109/78.124950 · Cited by 402
Time Frequency and Wavelets in Biomedical Signal Processing
Akay, M. (1997) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470546697 · Cited by 386
Time-frequency analysis of myoelectric signals during dynamic contractions: a comparative study
Karlsson, S., Yu, J., & Akay, M. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.821766 · Cited by 358
Myoelectric signal conduction velocity and spectral parameters: influence of force and time
Broman, H., Bilotto, G., & De Luca, C. J. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.58.5.1428 · Cited by 260
Self-citationEffects of electrode location on myoelectric conduction velocity and median frequency estimates
Roy, S. H., De Luca, C. J., & Schneider, J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.61.4.1510 · Cited by 260
Self-citationInference of motor unit recruitment order in voluntary and electrically elicited contractions
Knaflitz, M., Merletti, R., & De Luca, C. J. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.4.1657 · Cited by 251
Self-citationTime-frequency methods applied to muscle fatigue assessment during dynamic contractions
Knaflitz, M., & Bonato, P. (1999) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(99)00009-7 · Cited by 179
Self-citationRoy, S. H., De Luca, C. J., Emley, M., & Buijs, R. J. C. (1995) · Spine · doi:10.1097/00007632-199501000-00008 · Cited by 164
Self-citationBiedermann, H. J., Shanks, G. L., Forrest, W. J., & Inglis, J. (1991) · PubMed · Cited by 162
Modeling of surface myoelectric signals. II. Model-based signal interpretation
Merletti, R., Roy, S. H., Kupa, E. J., Roatta, S., & Granata, A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.771191 · Cited by 135
Self-citationPower Spectrum Analyses of Electromyographic Activity
Biedermann, H. J., Gl, S., FORREST, W. J., & INGLIS, J. (1991) · Spine · doi:10.1097/00007632-199110000-00009 · Cited by 125
The influence of an increase in the level of force on the EMG power spectrum of elbow extensors
Bilodeau, M., Arsenault, B. A., Gravel, D., & Bourbonnais, D. (1990) · European Journal of Applied Physiology · doi:10.1007/bf00236068 · Cited by 110
EMG assessment of back muscle function during cyclical lifting
Roy, S. H., Bonato, P., & Knaflitz, M. (1998) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00010-8 · Cited by 105
Self-citationLinssen, W. H. J. P., Stegeman, D. F., Joosten, E. M. G., BINKHORST, R. A., Merks, M. J. H., Laak, H. J. T., & Notermans, S. L. H. (1991) · Muscle & Nerve · doi:10.1002/mus.880140906 · Cited by 99
Detection of changes of signal structure by using the Wigner-Ville spectrum
Martin, W., & Flandrin, P. (1985) · Signal Processing · doi:10.1016/0165-1684(85)90075-1 · Cited by 62
Errors in frequency parameters of EMG power spectra
Hof, A. L. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.99071 · Cited by 51
Combined Use of Surface Electromyography and 31P-NMR Spectroscopy for the Study of Muscle Disorders
Roy, S. H. (1993) · Physical Therapy · doi:10.1093/ptj/73.12.892 · Cited by 18
Self-citation
Cited by
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
Outlook on human-centric manufacturing towards Industry 5.0
Lu, Y., Zheng, H., Chand, S., Xia, W., Liu, Z., Xu, X., Wang, L., Qin, Z., & Bao, J. (2022) · Journal of Manufacturing Systems · doi:10.1016/j.jmsy.2022.02.001 · Cited by 671
Interpretation of the Surface Electromyogram in Dynamic Contractions
Farina, D. (2006) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-200607000-00006 · Cited by 324
Electromyographic models to assess muscle fatigue
González-Izal, M., Malanda, A., Gorostiaga, E., & Izquierdo, M. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.02.019 · Cited by 310
A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue
Al-Mulla, M. R., Sepulveda, F., & Colley, M. (2011) · Sensors · doi:10.3390/s110403545 · Cited by 310
Metadata
- Authors
- Bonato, P., Roy, S. H., Knaflitz, M., & de Luca, C. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2001-07
- Volume
- 48
- Issue
- 7
- Pages
- 745-753
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2141087070
- Cited by
- 284
- References
- 26
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.