Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 471

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Entropy, entropy rate, and pattern classification as tools to typify complexity in short heart period variability series

Porta, A., Guzzetti, S., Montano, N., Furlan, R., Pagani, M., Malliani, A., Cerutti, S.·2001·IEEE Transactions on Biomedical Engineering

Abstract

An integrated approach to the complexity analysis of short heart period variability series (approximately 300 cardiac beats) is proposed and applied to healthy subjects during the sympathetic activation induced by head-up tilt and during the driving action produced by controlled respiration (10, 15, and 20 breaths/min, CR10, CR15, and CR20 respectively). The approach relies on: 1) the calculation of Shannon entropy (SE) of the distribution of patterns lasting three beats; 2) the calculation of a regularity index based on an entropy rate (i.e., the conditional entropy); 3) the classification of frequent deterministic patterns (FDPs) lasting three beats. A redundancy reduction criterion is proposed to group FDPs in four categories according to the number and type or of heart period changes: a) no variation (0V); b) one variation (1V); and c) two like variations (2LV); 4) two unlike variations (2UV). We found that: 1) the SE decreased during tilt due to the increased percentage of missing patterns; 2) the regularity index increased during tilt and CR10 as patterns followed each other according to a more repetitive scheme; and 3) during CR10, SE and regularity index were not redundant as the regularity index significantly decreased while SE remained unchanged. Concerning pattern analysis we found that: a) at rest mainly three classes (0V, 1V, and 2LV) were detected; b) 0V patterns were more likely during tilt; c) 1V and 2LV patterns were more frequent during CR10; and d) 2UV patterns were more likely during CR20. The proposed approach based on quantification of complexity allows a full characterization of heart period dynamics and the identification of experimental conditions known to differently perturb cardiovascular regulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.959324

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 471

Metadata

Authors
Porta, A., Guzzetti, S., Montano, N., Furlan, R., Pagani, M., Malliani, A., & Cerutti, S.
Venue
IEEE Transactions on Biomedical Engineering
Published
2001
Volume
48
Issue
11
Pages
1282-1291
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2171138447
Cited by
471
References
2
FWCI
0.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Entropy, entropy rate, and pattern classification as tools to typify complexity in short heart period variability series. https://app.cochat.ai/papers/10.1109/10.959324
The paper
Porta, A., Guzzetti, S., Montano, N., Furlan, R., Pagani, M., Malliani, A., & Cerutti, S. (2001). Entropy, entropy rate, and pattern classification as tools to typify complexity in short heart period variability series. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.959324

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.