The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
An advanced detrending method with application to HRV analysis
Abstract
An advanced, simple to use, detrending method to be used before heart rate variability analysis (HRV) is presented. The method is based on smoothness priors approach and operates like a time-varying finite-impulse response high-pass filter. The effect of the detrending on time- and frequency-domain analysis of HRV is studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Heart rate variability: origins, methods, and interpretive caveats
BERNTSON, G. G., THOMAS BIGGER, J., ECKBERG, D. L., GROSSMAN, P., KAUFMANN, P. G., MALIK, M., NAGARAJA, H. N., PORGES, S. W., SAUL, J. P., STONE, P. H., et al. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb02140.x · Cited by 3,962
A comparison of three quantification methods for estimation of respiratory sinus arrhythmia.
Grossman, P., van Beek, J., & Wientjes, C. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb03198.x · Cited by 381
Cited by
Kubios HRV–heart rate variability analysis software.
Tarvainen, M. P., Niskanen, J.-P., Lipponen, J. A., Ranta-aho, P. O., & Karjalainen, P. A. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.07.024 · Cited by 2,720
Self-citationImpact of views to school landscapes on recovery from stress and mental fatigue
Li, D., & Sullivan, W. C. (2016) · Landscape and Urban Planning · doi:10.1016/j.landurbplan.2015.12.015 · Cited by 706
Considerations in the assessment of heart rate variability in biobehavioral research
Quintana, D. S., & Heathers, J. A. J. (2014) · Frontiers in Psychology · doi:10.3389/fpsyg.2014.00805 · Cited by 395
Jarczok, M. N., Weimer, K., Braun, C., Williams, D. P., Thayer, J. F., Gündel, H. O., & Balint, E. M. (2022) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2022.104907 · Cited by 246
Development and Evaluation of an Ambulatory Stress Monitor Based on Wearable Sensors
Choi, J., Ahmed, B., & Gutierrez-Osuna, R. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2169804 · Cited by 221
Metadata
- Authors
- Tarvainen, M. P., Ranta-aho, P. O., & Karjalainen, P. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2002
- Volume
- 49
- Issue
- 2
- Pages
- 172-175
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W1994303078
- Cited by
- 1,131
- References
- 4
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.