Development and Evaluation of an Ambulatory Stress Monitor Based on Wearable Sensors
Abstract
Chronic stress is endemic to modern society. However, as it is unfeasible for physicians to continuously monitor stress levels, its diagnosis is nontrivial. Wireless body sensor networks offer opportunities to ubiquitously detect and monitor mental stress levels, enabling improved diagnosis, and early treatment. This article describes the development of a wearable sensor platform to monitor a number of physiological correlates of mental stress. We discuss tradeoffs in both system design and sensor selection to balance information content and wearability. Using experimental signals collected from the wearable sensor, we describe a selected number of physiological features that show good correlation with mental stress. In particular, we propose a new spectral feature that estimates the balance of the autonomic nervous system by combining information from the power spectral density of respiration and heart rate variability. We validate the effectiveness of our approach on a binary discrimination problem when subjects are placed under two psychophysiological conditions: mental stress and relaxation. When used in a logistic regression model, our feature set is able to discriminate between these two mental states with a success rate of 81% across subjects.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Several new prediction works have used experimental wearable sensor data to perform non-clinical health monitoring.
“However, there are several new prediction works which have used experimental wearable sensor data to perform non clinical health monitoring [26,42].”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [42]
Since wearable sensor data for vital sign parameters tend to be continuous time series readings, most considered features are related to properties of time series signals.
“Since Wearable sensor data which provide monitoring of vital sign parameters tend to be continuous time series readings, most of the considered features are related to the properties of time series signals [42].”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [42]
Among ANS responses, skin temperature, skin conductance, and arterial pulsewave signals are required for comprehensive multimodal physiological data analysis.
“Among ANS responses, the skin temperature1126, skin conductance112628, and arterial pulsewave11232628 signals are required for the comprehensive multimodal physiological data analysis.”
From A Flexible and Wearable Human Stress Monitoring Patch (2016) · cites this paper as [28]
The skin contact area of the fabricated multi-layer patch (3.71 cm2) is as small as 1/125 of that of the conventional single layer multimodal stress monitoring device (451 cm2).
“As a result, the skin contact area of the fabricated multi-layer patch (3.71 cm2) is as small as the 1/125 of that of the conventional single layer multimodal stress monitoring device (451 cm2)28.”
From A Flexible and Wearable Human Stress Monitoring Patch (2016) · cites this paper as [28]
Due to the nature of vital signs, some are essentially counted as continuous such as ECG, heart rate and respiration rate, or discrete like blood glucose level.
“Due to the nature of vital signs, some of them are essentially counted as continuous such as ECG, heart rate and respiration rate [31,42] or discrete like blood glucose level [28].”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [42]
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918 · see citing works
The WEKA data mining software: an update
Hall, M., Frank, E., Holmes, G., Pfahringer, B., Reutemann, P., & Witten, I. H. (2009) · ACM SIGKDD Explorations Newsletter · doi:10.1145/1656274.1656278 · Cited by 17,750 · see citing works
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159 · see citing works
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289 · see citing works
Health Behavior and Health Education: Theory, Research, and Practice
(1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-116-4-350_1 · Cited by 13,211 · see citing works
A Study of Cross-Validation and Bootstrap for Accuracy Estimation and Model Selection
Kohavi, R. (1995) · Zenodo · doi:10.5281/zenodo.19712698 · Cited by 10,909 · see citing works
Protective and Damaging Effects of Stress Mediators
McEwen, B. S. (1998) · New England Journal of Medicine · doi:10.1056/nejm199801153380307 · Cited by 6,733 · cited 1× · see citing works
“Suppression of the immune system leads to increased severity of the common cold [9] and increased susceptibility to infectious disease [10].”
BackgroundKirschbaum, C., Pirke, K.-M., & Hellhammer, D. H. (2008) · Neuropsychobiology · doi:10.1159/000119004 · Cited by 6,093 · see citing works
An Introduction to Kernel and Nearest-Neighbor Nonparametric Regression
Altman, N. (1992) · The American Statistician · doi:10.1080/00031305.1992.10475879 · Cited by 5,721 · see citing works
Combining labeled and unlabeled data with co-training
Blum, A. L., & Mitchell, T. M. (1998) · Conference on Learning Theory · doi:10.1145/279943.279962 · Cited by 5,597 · see citing works
(1998) · Cited by 3,476 · see citing works
Dawson, M., Schell, A., & Filion, D. L. (2007) · Cambridge University Press eBooks · doi:10.1017/cbo9780511546396.007 · Cited by 2,425 · see citing works
Cacioppo, J. T., Tassinary, L. G., Berntson, G. G., Shan, H., Mason, P., Kolb, B., Whishaw, I. Q., Geuter, S., Lindquist, M. A., Wager, T. D., et al. (2016) · Cambridge University Press eBooks · doi:10.1017/9781107415782 · Cited by 2,032 · see citing works
The use of leukocyte profiles to measure stress in vertebrates: a review for ecologists
Davis, A. K., Maney, D. L., & Maerz, J. C. (2008) · Functional Ecology · doi:10.1111/j.1365-2435.2008.01467.x · Cited by 1,558 · see citing works
An advanced detrending method with application to HRV analysis
Tarvainen, M. P., Ranta-aho, P. O., & Karjalainen, P. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.979357 · Cited by 1,135 · see citing works
Emotion recognition based on physiological changes in music listening
Kim, J., & André, E. (2008) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2008.26 · Cited by 1,079 · see citing works
(1976) · Elsevier eBooks · doi:10.1016/c2013-0-06263-9 · Cited by 982 · see citing works
Idiot's Bayes—Not So Stupid After All?
Hand, D. J., & Yu, K. (2001) · International Statistical Review · doi:10.1111/j.1751-5823.2001.tb00465.x · Cited by 886 · see citing works
Effects of Work Stress on Ambulatory Blood Pressure, Heart Rate, and Heart Rate Variability
Vrijkotte, T. G. M., van Doornen, L. J. P., & de Geus, E. J. C. (2000) · Hypertension · doi:10.1161/01.hyp.35.4.880 · Cited by 756 · see citing works
Sensor networks for medical care
Shnayder, V., Chen, B.-R., Lorincz, K., Fulford-Jones, T. R. F., & Welsh, M. (2005) · ACM Conference on Embedded Networked Sensor Systems (SenSys) · doi:10.1145/1098918.1098979 · Cited by 723 · see citing works
AMON: A Wearable Multiparameter Medical Monitoring and Alert System
Anliker, U., Ward, J. A., Lukowicz, P., Troster, G., Dolveck, F., Baer, M., Keita, F., Schenker, E. B., Catarsi, F., Coluccini, L., et al. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.837888 · Cited by 707 · see citing works
Decomposition of skin conductance data by means of nonnegative deconvolution
Benedek, M., & Kaernbach, C. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2009.00972.x · Cited by 632 · see citing works
Mandryk, R. L., & Atkins, M. S. (2007) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2006.11.011 · Cited by 538 · see citing works
Negative life events, perceived stress, negative affect, and susceptibility to the common cold.
Cohen, S., Tyrrell, D. A. J., & Smith, A. P. (1993) · Journal of Personality and Social Psychology · doi:10.1037/0022-3514.64.1.131 · Cited by 469 · see citing works
Gemperle, F., Kasabach, C., Stivoric, J., Bauer, M., & Martin, R. (2002) · International Symposium on Wearable Computers · doi:10.1109/iswc.1998.729537 · Cited by 452 · see citing works
Jimenez, L. O., & Landgrebe, D. A. (1998) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/5326.661089 · Cited by 418 · see citing works
Psychophysiological stress and emg activity of the trapezius muscle
Lundberg, U., Kadefors, R., Melin, B., Palmerud, G., Hassmén, P., Engström, M., & Elfsberg Dohns, I. (1994) · International Journal of Behavioral Medicine · doi:10.1207/s15327558ijbm0104_5 · Cited by 381 · see citing works
Effects of stress on heart rate complexity—A comparison between short-term and chronic stress
Schubert, C., Lambertz, M., Nelesen, R. A., Bardwell, W. A., Choi, J., & Dimsdale, J. E. (2008) · Biological Psychology · doi:10.1016/j.biopsycho.2008.11.005 · Cited by 378 · see citing works
Self-citationHypertension, Peptic Ulcer, and Diabetes in Air Traffic Controllers
Cobb, S., & Rose, R. M. (1973) · JAMA · doi:10.1001/jama.1973.03220170019004 · Cited by 334 · see citing works
Decomposing skin conductance into tonic and phasic components
Lim, C. L., RENNIE, C. J., Barry, R. J., Bahramali, H., Lazzaro, I., Manor, B. R., & Gordon, E. (1997) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(96)00713-1 · Cited by 226 · see citing works
A Multiparameter Wearable Physiologic Monitoring System for Space and Terrestrial Applications
Mundt, C. W., Montgomery, K. N., Udoh, U. E., Barker, V. N., Thonier, G. C., Tellier, A. M., Ricks, R. D., Darling, R. B., Cagle, Y. D., Cabrol, N. A., et al. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854509 · Cited by 226 · see citing works
Electrical properties of the skin
Edelberg, R. (1967) · Medical Entomology and Zoology · Cited by 214 · see citing works
Body area network for wireless patient monitoring
Monton, E., Hernandez, J. F., Blasco, J. M., Hervé, T., Micallef, J., Grech, I., Brincat, A. A., & Traver, V. (2008) · IET Communications · doi:10.1049/iet-com:20070046 · Cited by 196 · see citing works
Negative life events, perceived stress, negative affect, and susceptibility to the common cold
Cohen, S., Tyrrell, D., & Smith, A. (1993) · Journal of Personality and Social Psychology · doi:10.1037//0022-3514.64.1.131 · Cited by 178 · see citing works
Sensing Fabrics for Monitoring Physiological and Biomechanical Variables: E-textile solutions
Pacelli, M., Loriga, G., Taccini, N., & Paradiso, R. (2006) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmdbs.2006.360082 · Cited by 178 · see citing works
Developing multimodal intelligent affective interfaces for tele-home health care
Lisetti, C., Nasoz, F., LeRouge, C., Ozyer, O., & Alvarez, K. (2003) · International Journal of Human-Computer Studies · doi:10.1016/s1071-5819(03)00051-x · Cited by 165 · see citing works
Separating individual skin conductance responses in a short interstimulus-interval paradigm
Alexander, D. M., Trengove, C., Johnston, P., Cooper, T., August, J. P., & Gordon, E. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.02.001 · Cited by 160 · see citing works
MIThril 2003: applications and architecture
DeVaul, R. W., Sung, M., Gips, J., et al. (2004) · Proceedings · doi:10.1109/iswc.2003.1241386 · Cited by 159 · see citing works
El‐Sheikh, M. (2005) · Journal of Child Psychology and Psychiatry · doi:10.1111/j.1469-7610.2005.00418.x · Cited by 151 · see citing works
Kasl, S. V. (1984) · Annual Review of Public Health · doi:10.1146/annurev.pu.05.050184.001535 · Cited by 113 · see citing works
A Cohort Study of Stress and the Common Cold
Takkouche, B., Regueira‐Méndez, C., & Gestal, J. J. (2001) · Epidemiology · doi:10.1097/00001648-200105000-00015 · Cited by 111 · see citing works
Maintaining Optimal Challenge in Computer Games through Real-Time Physiological Feedback
Rani, P., Sarkar, N., & Liu, C. (2005) · Cited by 108 · see citing works
Affectively intelligent and adaptive car interfaces
Nasoz, F., Lisetti, C. L., & Vasilakos, A. (2010) · Information Sciences · doi:10.1016/j.ins.2010.06.034 · Cited by 104 · see citing works
Association of Chronic Stress With Plasminogen Activator Inhibitor–1 in Healthy Middle-aged Men
Räikkönen, K., Lassila, R., Keltikangas‐Järvinen, L., & Hautanen, A. (1996) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.16.3.363 · Cited by 96 · see citing works
What Does Your Chair Know About Your Stress Level?
Arnrich, B., Setz, C., Marca, R. L., et al. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2035498 · Cited by 95 · see citing works
RELATION OF ELECTRICAL PROPERTIES OF SKIN TO STRUCTURE AND PHYSIOLOGIC STATE
Edelberg, R. (1977) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12507771 · Cited by 85 · see citing works
Hypertension, peptic ulcer, and diabetes in air traffic controllers
Cobb, S. (1973) · JAMA · doi:10.1001/jama.224.4.489 · Cited by 77 · see citing works
Sensor Acceptance Model – Measuring Patient Acceptance of Wearable Sensors
Pedersen, P. E., GUNDERSEN, T., Hejlesen, O. K., & Fensli, R. W. (2007) · Methods of Information in Medicine · doi:10.3414/me9106 · Cited by 70 · see citing works
Luneski, A., Konstantinidis, E. I., & Bamidis, P. D. (2010) · Methods of Information in Medicine · doi:10.3414/me0617 · Cited by 67 · see citing works
Brüllmann, G., Fritsch, K., Thurnheer, R., & Bloch, K. E. (2009) · Respiration · doi:10.1159/000212117 · Cited by 52 · see citing works
Electrode Motion Artifacts in Electrical Impedance Pneumography
Sahakian, A. V., Tompkins, W. J., & Webster, J. G. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325453 · Cited by 49 · see citing works
Estimating mental stress using a wearable cardio-respiratory sensor
Choi, J., & Gutiérrez‐Osuna, R. (2010) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2010.5690677 · Cited by 17 · see citing works
Self-citationAn automated system for processing electrodermal activity.
Frantzidιs, C. A., Konstantinidis, E. I., Pappas, C., & Bamidis, P. D. (2009) · PubMed · Cited by 8 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Wearable Sensors for Human Activity Monitoring: A Review
Mukhopadhyay, S. C. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2370945 · Cited by 1,401 · see citing works
Banaee, H., Ahmed, M., & Loutfi, A. (2013) · Sensors · doi:10.3390/s131217472 · Cited by 452 · see citing works
Artificial intelligence-powered electronic skin
Xu, C., Solomon, S. A., & Gao, W. (2023) · Nature Machine Intelligence · doi:10.1038/s42256-023-00760-z · Cited by 259 · see citing works
A Flexible and Wearable Human Stress Monitoring Patch
Yoon, S., Sim, J. K., & Cho, Y.-H. (2016) · Scientific Reports · doi:10.1038/srep23468 · Cited by 151 · see citing works
micro-Stress EMA: A Passive Sensing Framework for Detecting in-the-wild Stress in Pregnant Mothers
King, Z. D., Moskowitz, J., Egilmez, B., Zhang, S., Zhang, L., Bass, M., Rogers, J., Ghaffari, R., Wakschlag, L., & Alshurafa, N. (2019) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3351249 · Cited by 73 · see citing works
Wang, H., Li, J., McDonald, B. E., Farrell, T. R., Huang, X., & Clancy, E. A. (2023) · Sensors · doi:10.3390/s23052465 · Cited by 18 · see citing works
- Authors
- Choi, J., Ahmed, B., & Gutierrez-Osuna, R.
- Affiliations
- Texas A&M University (US)
- Texas A&M University at Qatar (QA)
- ORCID
- Ahmed, B.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2012-03
- Volume
- 16
- Issue
- 2
- Pages
- 279-286
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2050284630
- Semantic Scholar
- 74fb3a4c124a20fd2f3f31510bd146ace378f30e
- Cited by
- 221
- References
- 53
- Citations by year
- 2026: 6 · 2025: 15 · 2024: 21 · 2023: 15 · 2022: 16 · 2021: 21 · 2020: 25 · 2019: 21 · 2018: 10 · 2017: 14 · 2016: 15 · 2015: 16 · 2014: 9 · 2013: 13 · 2012: 4
- FWCI
- 10.75
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Information Technology in Biomedicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Emotion and Mood Recognition
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- wearable sensors, wireless body sensor networks, sympathovagal balance, heart rate variability, respiration, power spectral density, physiological traits, stress detection, logistic regression classification
- MeSH terms
- Clothing, Electric Conductivity, Electromyography, Equipment Design, Heart Rate, Humans, Models, Biological, Relaxation, Respiration, Signal Processing, Computer-Assisted, Skin Physiological Phenomena, Stress, Psychological, Reproducibility of Results, Logistic Models, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review