The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Specific absorption rate and temperature increases in the head of a cellular-phone user
Abstract
In this paper, a complete electromagnetic and thermal analysis has been performed considering the head of a subject exposed to various kinds of cellular phones available on the market, and focusing the attention on important organs like the eye lens and brain. Attention has first been posed on a particular phone model, and a comparison between the absorbed power distribution and steady-state temperature increases has been carried out. The influence of different antennas (dipole, monopole, whip, and planar inverted F antenna) on the power absorption and on the consequent tissue heating has then been analyzed. The obtained results show for a radiated power of 600 mW, maximum SAR values, averaged over 1 g, from 2.2 to 3.7 W/kg depending on the considered phone. The maximum temperature increases are obtained in the ear and vary from 0.22/spl deg/C to 0.43/spl deg/C, while the maximum temperature increases in the brain lie from 0.08/spl deg/C to 0.19/spl deg/C. These steady-state temperature increases are obtained after about 50 min of exposure, with a time constant of approximately 6 min. Finally, the results evidence a maximum temperature increase in the external part of the brain from 0.10/spl deg/C to 0.16/spl deg/C for every 1 W/kg of SAR, averaged over 1 g of brain tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computational Electrodynamics: The Finite-Difference Time-Domain Method
Taflove, A. (1995) · Cited by 10,626
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
Computational electrodynamics, the finite-difference time-domain method
Rycroft, M. J. (1996) · Journal of Atmospheric and Terrestrial Physics · doi:10.1016/0021-9169(96)80449-1 · Cited by 9,418
Ahlbom, A. (1998) · Health Physics · Cited by 5,083
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
Mur, G. (1981) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.1981.303970 · Cited by 2,565
The Finite Difference Time Domain Method for Electromagnetics
Kunz, K. S., & Luebbers, R. J. (2018) · CRC Press eBooks · doi:10.1201/9780203736708 · Cited by 2,518
Duck, F. A. (1990) · Cited by 2,461
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Physical properties of tissue: F. A. Duck Harcourt Brace Jovanovich Ltd, London; 1990, 346 pp.
Bowker, P. (1991) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(91)90034-5 · Cited by 608
Metadata
- Authors
- Bernardi, P., Cavagnaro, M., Pisa, S., & Piuzzi, E.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2000-07
- Volume
- 48
- Issue
- 7
- Pages
- 1118-1126
- ISSN
- 0018-9480 (ISSN-L)
- OpenAlex
- W2160926456
- Cited by
- 278
- References
- 25
- FWCI
- 9.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Specific absorption rate and temperature increases in the head of a cellular-phone user. https://app.cochat.ai/papers/10.1109/22.848494
- The paper
- Bernardi, P., Cavagnaro, M., Pisa, S., & Piuzzi, E. (2000). Specific absorption rate and temperature increases in the head of a cellular-phone user. IEEE Transactions on Microwave Theory and Techniques. https://doi.org/10.1109/22.848494
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.