Physical characteristics of TTV03, a new high spatial resolution time-of-flight positron tomograph
The DOI matches its Crossref record.
Abstract
TTV03, a novel high-spatial-resolution TOF-PET (time-of-flight positron emission tomography) system, is presented. The machine consists of four 89-cm-diameter rings made of 7-mm-wide, 18-mm-high, 45-mm-deep BaF/sub 2/ crystals (324 per ring) individually coupled to 11-mm-diameter phototubes. The transaxial resolution (full width at half maximum or FWHM) in the reconstructed image is 5.7 mm at center, 5.7 mm (tangential), and 6.5 mm (radial) at 10 cm. The axial resolution is 8.8 mm (direct plane) and 6.7 mm (crossplane) at center, and 10.3 mm (direct) and 11.2 mm (cross) at 10 cm from center. With a 150-keV threshold, the TOF resolution is 750 ps (FWHM), and, with a 4.18-ns coincidence window, the sensitivity (true evts/s per mu Ci/cm/sup 3/) is 9800 (direct plane) and 14300 (crossplane). At 1 mu Ci/cm/sup 3/, the ratio of random events to true events is .20 for the total and .03 per image element, and the scatter fraction is 22%. Dead time losses are 8.3% at 2.5 mu Ci/cm/sup 3/ (four rings), but the tomograph can handle activities over 50 mu Ci/cm/sup 3/ in small regions with negligible losses. These characteristics make TTV03 particularly suitable for dynamic brain and heart H/sub 2//sup 15/ bolus studies.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Cortical Representation of Speech
Mazoyer, B. M., Tzourio, N., Frak, V., Syrota, A., Murayama, N., Levrier, O., Salamon, G., Dehaene, S., Cohen, L., & Mehler, J. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.4.467 · Cited by 715
Self-citationBenefit of Time-of-Flight in PET: Experimental and Clinical Results
Karp, J. S., Surti, S., Daube-Witherspoon, M. E., & Muehllehner, G. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.044834 · Cited by 584
Spontaneous neurological recovery after stroke and the fate of the ischemic penumbra
Furlan, M., Marchal, G., Derlon, J., Baron, J., & Viader, F. (1996) · Annals of Neurology · doi:10.1002/ana.410400213 · Cited by 519
Neuroanatomical Correlates of Visually Evoked Sexual Arousal in Human Males
Stoleru, S., Gregoire, M.-C., Gerard, D., Decety, J., Lafarge, E., Cinotti, L., Lavenne, F., Bars, D. L., Vernet-Maury, E., Rada, H., et al. (1999) · Archives of Sexual Behavior · doi:10.1023/a:1018733420467 · Cited by 421
Self-citationVoxel-based mapping of irreversible ischaemic damage with PET in acute stroke
Marchal, G., Benali, K., Iglesias, S., Viader, F., Derlon, J.-M., & Baron, J.-C. (1999) · Brain · doi:10.1093/brain/122.12.2387 · Cited by 382
Metadata
- Authors
- Mazoyer, B., Trebossen, R., Schoukroun, C., Verrey, B., Syrota, A., Vacher, J., Lemasson, P., Monnet, O., Bouvier, A., & Lecomte, J. L.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 1990-04
- Volume
- 37
- Issue
- 2
- Pages
- 778-782
- ISSN
- 0018-9499 (ISSN-L)
- 1558-1578
- OpenAlex
- W2119404327
- Cited by
- 102
- References
- 0
- FWCI
- 6.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physical characteristics of TTV03, a new high spatial resolution time-of-flight positron tomograph. https://app.cochat.ai/papers/10.1109/23.106714
- The paper
- Mazoyer, B., Trebossen, R., Schoukroun, C., Verrey, B., Syrota, A., Vacher, J., Lemasson, P., Monnet, O., Bouvier, A., & Lecomte, J. L. (1990). Physical characteristics of TTV03, a new high spatial resolution time-of-flight positron tomograph. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/23.106714
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.