Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: myocardial perfusion assessment

Blankespoor, S.C., Xu, X., Kaiki, K., Brown, J.K., Tang, H.R., Cann, C.E., Hasegawa, B.H. · 1996 · IEEE Transactions on Nuclear Science

Abstract

The authors present experimental results for attenuation correction of emission tomography through use of an attenuation map derived from X-ray CT data. The X-ray and gamma-ray data were obtained from a third-generation X-ray CT scanner and a single-headed SPECT Scanner juxtaposed to enable systematic registration of SPECT and X-ray CT Images. CT measurements were obtained from known materials at a given X-ray technique, then related to attenuation coefficients at 140 keV. The resulting calibration data were used to generate attenuation maps for the coregistered SPECT data. In addition, phantom studies provided recovery coefficients as a function of object size to compensate for partial volume effects in the coregistered radionuclide data. This technique has been applied to a torso phantom, yielding attenuation maps with an average accuracy error <1%. Reconstruction of the SPECT image without attenuation correction underestimated the regional myocardial activity errors with an average accuracy error of -90%. Reconstruction with attenuation correction reduced the average accuracy error to -37%, but addition of a partial volume correction overestimated the regional myocardial activity concentration by an average error of 94%. The technique has also been applied to small pigs in myocardial perfusion studies by correlating the image-derived myocardial activity concentrations with those obtained directly from excised tissue samples. Correcting for attenuation increased the slope of the regression line from 0.16 to 0.36 (compared with an ideal slope of 1.00.) Adding an additional correction for partial volume effects improved the slope of the regression line to 0.93. The absolute precision error (standard error of the estimate) obtained without correction (2.14 /spl mu/Ci/ml) was degraded by attenuation correction (4.23 /spl mu/Ci/ml) and was also degraded by adding a correction for partial volume errors (10 89 /spl mu/Ci/ml), although the relative precision error without correction (31.2%) was improved by attenuation correction to 27.6% when the images were reconstructed with attenuation correction alone or with a combination of attenuation correction and compensation for partial volume effects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/23.531891

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 170

Metadata

Authors
Blankespoor, S. C., Xu, X., Kaiki, K., Brown, J. K., Tang, H. R., Cann, C. E., & Hasegawa, B. H.
Venue
IEEE Transactions on Nuclear Science
Published
1996-08
Volume
43
Issue
4
Pages
2263-2274
ISSN
  • 0018-9499 (ISSN-L)
  • 1558-1578
OpenAlex
W2033932611
Cited by
170
References
2
FWCI
3.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: myocardial perfusion assessment. https://app.cochat.ai/papers/10.1109/23.531891
The paper
Blankespoor, S. C., Xu, X., Kaiki, K., Brown, J. K., Tang, H. R., Cann, C. E., & Hasegawa, B. H. (1996). Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: myocardial perfusion assessment. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/23.531891

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.