A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners

Joseph, Peter M., Spital, Robin D.·1978·Journal of Computer Assisted Tomography

Abstract

A method that corrects for artifacts in X-ray transmission scanners created by the alteration of the energy spectrum by bone is described. The method involves two reconstructions of the pictures: the first establishes the approximate distribution of bone and the second enables the artifacts to be eliminated. The first reconstruction is needed to establish the total amount of bone along each ray. Assuming that the X-ray energy spectrum is known, it is shown how the line integrals can be corrected. The method was tested on several mathematical phantoms as well as on human head data. The nonlinear nature of the spectral artifacts is shown to produce streaks in certain phantoms.

Integrity signals

Registry

Crossref · 10.1097/00004728-197801000-00017

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The large extracranial metal components and dental cement of the implant can cause beam hardening that can appear as cupping, streaks, dark bands or flare in the μCT.

    “the large extracranial metal components and dental cement of the implant can cause beam hardening that can appear as cupping, streaks, dark bands or flare in the µCT38–40.”

Cited by

Sorted by citations

Authors
Joseph, P. M., & Spital, R. D.
Affiliations
NewYork–Presbyterian Hospital (US)
Venue
Journal of Computer Assisted Tomography
Published
1978-01
Volume
2
Issue
1
Pages
100-108
ISSN
0363-8715 (ISSN-L)
OpenAlex
W2000441297
Cited by
281
References
0
Citations by year
2026: 7 · 2025: 4 · 2024: 10 · 2023: 6 · 2022: 13 · 2021: 6 · 2020: 9 · 2019: 12 · 2018: 17 · 2017: 10 · 2016: 10 · 2015: 9 · 2014: 10 · 2013: 10 · 2012: 13
FWCI
8.33
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Computer Assisted Tomography (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
Keywords
bone artifacts, spectral artifacts, X-ray spectra, streak artifacts, head CT, image reconstruction, mathematical phantoms
MeSH terms
Bone and Bones, Humans, Mathematics, Models, Structural, Skull, Technology, Radiologic, Tomography, X-Ray Computed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review