Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 240

The DOI matches its Crossref record.

Prospects for time-of-flight PET using LSO scintillator

Moses, W.W., Derenzo, S.E.·1999·IEEE Transactions on Nuclear Science

Abstract

We present measurements of the timing properties of lutetium orthosilicate (LSO) scintillator crystals coupled to a photomultiplier tube (PMT) and excited by 511 keV photons. These crystals have dimensions suitable for use in PET cameras (3/spl times/3/spl times/30 mm/sup 3/). Coincidence timing resolution of 475 ps fwhm is measured between detectors utilizing two such crystals, significantly worse than the 300 ps fwhm predicted based on first principles for small crystals and measured in 3 mm cubes. This degradation is found to be caused by the scintillation light undergoing multiple reflections at quasi-random angles within the scintillator crystal, which has two effects. First, it slows down the effective information propagation speed within the crystal (to an effective n/spl circ/=3.9-5.3). Since the incident annihilation photon travels with n=1, information from interactions at different depths arrives at the PMT with different time delays. Second, the random nature of the reflection angles (and path lengths) introduce dispersion and so a 10%-90% rise time of 1 ns to the optical signal.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/23.775565

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Moses, W. W., & Derenzo, S. E.
Venue
IEEE Transactions on Nuclear Science
Published
1999-06
Volume
46
Issue
3
Pages
474-478
ISSN
  • 0018-9499 (ISSN-L)
  • 1558-1578
OpenAlex
W2159519473
Cited by
240
References
0
FWCI
2.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.